Operational Test of a Potable Water Heater
TASK 38-12-00-710-004-A
Operational Test of a Potable Water Heater
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 38-12-00-861-053-A Subtask 38-12-00-865-058-A
Subtask 38-12-00-710-055-E ** ON A/C NOT FOR ALL
Subtask 38-12-00-410-053-A
[Rev.10 from 2021]
2026.04.01 01:18:06 UTC
Operational Test of a Potable Water Heater
NOTE: The test of the water heater in one lavatory is given. The procedure is the same for all the other water heaters.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | CART - SERVICING, WATER, POTABLE |
| No specific | 1 | FLASHLIGHT |
| No specific | 1 | MIRROR - INSPECTION, FLEXIBLE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-15-38-613-001-A | Fill the Potable Water Tank System (Aircraft Electrical Power Available) |
| TASK 12-24-38-680-001-A | Draining of the Potable Water System (with Electrical Power) |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 38-10-00-614-001-A | Pressurization of the Potable Water System from a Ground Air Supply |
| TASK 38-10-00-614-002-A | Depressurization of the Potable Water System |
Subtask 38-12-00-861-053-A Subtask 38-12-00-865-058-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 38-12-00-010-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | LAV FWD & MID-HOT WATER-A | 1MB | F02 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | LAV FWD-HOT WATER-A | 1MB | F02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LAVATORY AFT-HOT WATER-D | 2MB | B02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LAV AFT-HOT WATER-E | 9MB | B03 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LAV AFT-HOT WATER-D | 2MB | B02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LAV AFT-HOT WATER-G | 9MB | B03 |
| 2001VU | LAV AFT-HOT WATER-D/F | 2MB | B02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LAV AFT-HOT WATER | 9MB | B03 |
| 2001VU | LAV AFT-HOT WATER | 2MB | B02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LAV AFT-HOT WATER-E/L | 9MB | B03 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LAV AFT-HOT WATER-L | 9MB | C04 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LAV AFT-HOT WATER-D/L | 2MB | B02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LAV AFT-HOT WATER-M | 9MB | B03 |
C. Get Access
(1) Open the lavatory door.
(2) Open the sanitary cabinet door.
(3) Make sure that the water heater switch is in the OFF position:
(a) If necessary, use a FLASHLIGHT and MIRROR - INSPECTION, FLEXIBLE to find the power switch of the water heater.
(4) Make sure that the shutoff valve in the potable water system is in the OPEN position.
Subtask 38-12-00-680-050-A Subtask 38-12-00-480-051-A (1) Open the lavatory door.
(2) Open the sanitary cabinet door.
(3) Make sure that the water heater switch is in the OFF position:
(a) If necessary, use a FLASHLIGHT and MIRROR - INSPECTION, FLEXIBLE to find the power switch of the water heater.
(4) Make sure that the shutoff valve in the potable water system is in the OPEN position.
E. Connect the CART - SERVICING, WATER, POTABLE to the FILL port at the service panel but do not fill at this time.
4. ProcedureSubtask 38-12-00-710-055-E ** ON A/C NOT FOR ALL
A. Operational Test of the Water Heater
Subtask 38-12-00-710-055-F ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.In the lavatory:
| In the lavatory:
|
NOTE: The indicator light on the water heater will only go off when:
| |
2.At service panel 2023VU:
| In the potable water system: |
NOTE: You can fill the system with a minimum of 10% water quantity to do this test. | |
|
|
3.In the lavatory:
| In the lavatory:
|
4.In the water heater system:
| |
5.In the lavatory:
| |
|
|
6.In the lavatory:
| In the lavatory:
|
|
|
7.At the potable-water service panel:
| |
8.In the lavatory:
| In the lavatory:
NOTE: The Water Low Level-Sensor (in the tank of the water heater) will de-energize the heating circuit (when the water level falls below the sensor), but the indication light will stay on. |
A. Operational Test of the Water Heater
Subtask 38-12-00-210-053-A | ACTION | RESULT |
|---|---|
1.In the lavatory:
| In the lavatory:
|
NOTE: The control light on the water heater will only go off when:
| |
2.At the service panel 2023VU:
| In the potable water system: |
NOTE: You must fill the system with minimum 10% water quantity to do this test. | |
|
|
3.In the lavatory:
| In the lavatory:
|
4.In the water heater system:
| |
5.In the lavatory:
| In the lavatory:
|
6.In the lavatory:
| In the lavatory:
|
7.In the lavatory:
| In the lavatory:
|
8.At the potable-water service panel:
| |
9.In the lavatory:
| In the lavatory:
NOTE: The Water Low level-Sensor (in the tank of the water heater) will de-energize the heating circuit (when the water level falls below the sensor), but the indication light will stay on. |
B. Examine the work area and make sure that there are no leaks.
Subtask 38-12-00-613-055-A 5. Close-upNOTE: Leaks are not permitted.
Subtask 38-12-00-410-053-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the sanitary cabinet door.
(3) Close the lavatory door.
Subtask 38-12-00-862-053-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the sanitary cabinet door.
(3) Close the lavatory door.