Depressurization of the Potable Water System
TASK 38-10-00-614-002-A
Depressurization of the Potable Water System
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 38-10-00-861-053-A Subtask 38-10-00-865-053-A
Subtask 38-10-00-614-054-A ** ON A/C NOT FOR ALL
Subtask 38-10-00-862-051-A Subtask 38-10-00-410-057-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 04:23:10 UTC
Depressurization of the Potable Water System
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 171AL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
Subtask 38-10-00-861-053-A Subtask 38-10-00-865-053-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 38-10-00-210-054-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WATER SYSTEM-QANT-IND | 1MA | B01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-QUANT-IND | 1MA | B06 |
C. Make sure that the APU BLEED switch on the AIR COND panel 30VU is set to OFF if the APU is running.
Subtask 38-10-00-010-055-A ** ON A/C NOT FOR ALL D. Get Access
(1) Open the lavatory door.
(2) Put the ACCESS PLATFORM 2M (6 FT) in position at Zone 171.
(3) Open the access door 171AL.
Subtask 38-10-00-010-055-B ** ON A/C NOT FOR ALL (1) Open the lavatory door.
(2) Put the ACCESS PLATFORM 2M (6 FT) in position at Zone 171.
(3) Open the access door 171AL.
D. Get Access
(1) Open the Lavatory door.
4. Procedure(1) Open the Lavatory door.
Subtask 38-10-00-614-054-A ** ON A/C NOT FOR ALL
A. Depressurization of the Potable Water System
(1) Turn and pull the fill and drain handle at service panel 2023VU from the NORMAL position to the FILL position.
(2) Operate the water faucet in the lavatories to let air into the system.
(3) Push and turn the fill and drain handle to the NORMAL position.
Subtask 38-10-00-614-054-B ** ON A/C NOT FOR ALL (1) Turn and pull the fill and drain handle at service panel 2023VU from the NORMAL position to the FILL position.
(2) Operate the water faucet in the lavatories to let air into the system.
(3) Push and turn the fill and drain handle to the NORMAL position.
A. Depressurization of the Potable Water System
(1) Press the membrane switch 'WATER SYS DEPRESS' on the FAP 124RH until the light comes on.
(3) Reactivation of the potable Water System
(a) Press the membrane switch 'WATER SYS DEPRESS' on the FAP 124RH again.
(b) The light in the membrane switch 'WATER SYS DEPRESS' is off.
Subtask 38-10-00-614-054-C ** ON A/C NOT FOR ALL (1) Press the membrane switch 'WATER SYS DEPRESS' on the FAP 124RH until the light comes on.
NOTE: The light in the membrane switch comes on when the depressurization valve 4MD opens.
(2) Operate the water faucet in the lavatories to let air into the system. (3) Reactivation of the potable Water System
(a) Press the membrane switch 'WATER SYS DEPRESS' on the FAP 124RH again.
(b) The light in the membrane switch 'WATER SYS DEPRESS' is off.
A. Depressurization of the Potable Water System
(1) Push the 'WATER DEPRESS' button on the FAP 120RH:
(3) Reactivation of the Potable water System
(a) Push the 'WATER DEPRESS' button on the FAP 120RH again.
(b) The green light in the 'WATER DEPRESS' button is off.
(4) No more messages are shown on the FAP.
5. Close-up(1) Push the 'WATER DEPRESS' button on the FAP 120RH:
- The green light in the button comes on.
- The message 'VACUUM SYSTEM DISABLED - WATER DEPRESS ACTIVE' comes on.
- On the aircraft symbol 'NO WATER PRESSURE' comes in view.
NOTE: The green light in the 'WATER DEPRESS' button comes on when the depressurization valve 4MD opens.
(2) Operate the water faucet in the lavatories to let air into the system. (3) Reactivation of the Potable water System
(a) Push the 'WATER DEPRESS' button on the FAP 120RH again.
(b) The green light in the 'WATER DEPRESS' button is off.
(4) No more messages are shown on the FAP.
Subtask 38-10-00-862-051-A Subtask 38-10-00-410-057-A ** ON A/C NOT FOR ALL
B. Close Access
(1) Close the lavatory door.
(2) Close the service door 171AL.
(3) Remove the access platform(s).
Subtask 38-10-00-410-057-B ** ON A/C NOT FOR ALL (1) Close the lavatory door.
(2) Close the service door 171AL.
(3) Remove the access platform(s).
B. Close Access
(1) Close the lavatory door.
(1) Close the lavatory door.
Forward Attendant Panel 124RH