W DOC AIRBUS | AMM A320F

Reactivation of LGCIU-2


TASK 32-31-00-440-804-A
Reactivation of LGCIU-2


ZONE: 210
FIN: 5GA2
1. Reason for the Job
MMEL 32-31-01
LANDING GEAR CONTROL AND INTERFACE UNIT NO. 2 (FAA ONLY)
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 32-00-00-860-001-A
Flight Configuration Precautions with Electrical Power
TASK 32-00-00-860-001-A-01
Flight Configuration Precautions without Electrical Power
TASK 32-00-00-860-002-A
Ground Configuration after Flight Configuration with Electrical Power
TASK 32-00-00-860-002-A-01
Ground Configuration after Flight Configuration without Electrical Power
TASK 32-31-00-720-002-A
Functional Test of the Normal Extension and Retraction of the Landing Gear
TASK 32-69-00-740-001-A
BITE Check of Landing-Gear Control Interface-Unit (LGCIU) With Use of MCDU to Ensure that Continuous BITE is Operative
3. Job Set-up
Subtask 32-31-00-861-063-A
A. Aircraft Maintenance Configuration
   (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 32-31-00-941-103-A
B. Safety Precautions
   (1) Obey the applicable safety precautions (Ref. AMM TASK 32-00-00-860-001).
Subtask 32-31-00-865-143-A
C. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VULGCIU/BAT SPLY/SYS259GAR33
** ON A/C ALL
121VUHYDRAULIC/LGCIU/SYS22GAQ35
** ON A/C NOT FOR ALL
121VULGCIU/BAT SPLY/SYS259GAR32
4. Procedure
Subtask 32-31-00-440-054-A
A. Reactivation of LGCIU-2
   (1) Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
  • 2GA
  • 59GA.
   (2) After you close the LGCIU circuit breaker, put the aircraft back to the ground configuration (Ref. AMM TASK 32-00-00-860-002).
Subtask 32-31-00-740-052-A
B. BITE
   (1) Do the BITE test of the LGCIU (Ref. AMM TASK 32-69-00-740-001).
NOTE: As an alternative procedure, you can do the functional test normal extension and retraction of the landing gear (Ref. AMM TASK 32-31-00-720-002).
5. Close-up
Subtask 32-31-00-410-087-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
Subtask 32-31-00-860-154-A
B. Put the aircraft back to its initial configuration.
   (1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).