W DOC AIRBUS | AMM A320F

Ground Configuration after Flight Configuration without Electrical Power


TASK 32-00-00-860-002-A-01
Ground Configuration after Flight Configuration without Electrical Power


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Reason for the Job
To put the aircraft back to the correct (ground) configuration after it was in a flight configuration without electrical power.
NOTE: Do this task only if you have done the Flight Configuration Precautions without Electrical Power procedure (Ref. TASK 32-00-00-860-001-A-01).
2. Job Set-up
Subtask 32-00-00-869-066-A
A. Not Applicable
3. Procedure
Subtask 32-00-00-860-068-A
A. Aircraft Maintenance Configuration
   (1) On the ELEC panel 35VU, set the EXT PWR pushbutton switch to the ON position.
   (2) On the panel 2000VU, set the MAINT BUS switch to the ON position.
[Rev.10 from 2021] 2026.04.01 00:39:19 UTC