Removal of the MLG Hydraulic Dressings
TASK 32-11-12-000-001-A
Removal of the MLG Hydraulic Dressings
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 32-11-12-941-053-A
Subtask 32-11-12-020-050-F ** ON A/C NOT FOR ALL
MLG Hydraulic Dressings (MLG with Four-Piece Hydraulic Transfer-Block Assembly) ** ON A/C NOT FOR ALL
(1) Install the PLUG - BLANKING immediately after you remove the applicable flexible hydraulic hoses and rigid pipes.
(2) To remove the flexible hydraulic hoses, do the steps that follow:
(a) If necessary, remove and discard the lockwire from the unions (1), (14), (15) and (28).
(b) Loosen the unions (1), (14), (15) and (28) to let the hydraulic fluid drain.
(c) If the cotter pins (8) are installed, remove and discard them.
(d) Remove the nuts (7), the washers (6), the bolts (3), the washers (4) and the block assemblies (5).
(e) Disconnect the unions (1) and (14). Remove the flexible hoses (2) and (13).
(f) If the cotter pins (19) are installed, remove and discard them.
(g) Remove the nuts (20), the washers (21), the bolts (17), the washers (18) and the block assemblies (22).
(h) Disconnect the unions (15) and (28). Remove the flexible hoses (16) and (27).
(i) Remove the nuts (33), the washers (34) and the bolts (36). Remove the block assemblies (35).
(j) Remove and discard the cotter pin (41).
(k) Remove the nuts (40), the washers (39) and the bolts (37). Remove the channels (38).
(l) Disconnect the unions (23) and (71) and remove the flexible hose (24).
(m) Disconnect the unions (26) and (72) and remove the flexible hose (25).
(n) Disconnect the unions (10) and (74) and remove the flexible hose (9).
(o) Disconnect the unions (12) and (75) and remove the flexible hose (11)
(p) Disconnect the union (30) and remove the flexible hose (29).
(q) Disconnect the union (31) and remove the flexible hose (32).
(r) Disconnect the union (59) and remove the flexible hose (66).
(s) Disconnect the union (60) and remove the flexible hose (65).
(3) To remove the rigid hydraulic pipes, do the steps that follow:
(a) Remove and discard the lockwire from the band-clamp nuts (91).
(b) Loosen the nuts (91) sufficiently to remove the band-clamps (92) from the line support blocks.
1 Make sure that the mystic tape and the blocks stay in position when the band-clamps (92) are removed.
(c) Disconnect the unions (67) and (79) and remove the pipe (68).
(d) Disconnect the unions (70) and (78) and remove the pipe (69).
(e) Disconnect the union (77) and remove the locknut (57). Remove the pipe (56).
(f) Disconnect the union (80) and remove the locknut (58). Remove the pipe (55).
(g) Remove the locknut (76) and disconnect the union (64). Remove the pipe (63).
(h) Remove the locknut (73) and disconnect the union (61). Remove the pipe (62).
Subtask 32-11-12-020-050-J ** ON A/C NOT FOR ALL
MLG Hydraulic Dressings (MLG with Four-Piece Hydraulic Transfer-Block Assembly) ** ON A/C NOT FOR ALL
(1) Install a PLUG - BLANKING immediately after you remove the applicable flexible hydraulic hoses and the rigid pipes.
(2) To remove the flexible hydraulic hoses, do the steps that follow:
(a) Remove and discard the lockwire from the unions (1), (13), (14) and (26).
(b) Loosen the unions (1), (13), (14) and (26) to let the hydraulic fluid drain.
(c) Remove the nuts (7), the washers (6), the bolts (3), the washers (4) and the line-support block assemblies (5).
(d) Disconnect the unions (1) and (13). Remove the flexible hoses (2) and (12).
(e) Remove the nuts (18), the washers (19), the bolts (16), the washers (17) and the line-support block assemblies (20).
(f) Disconnect the unions (14) and (26). Remove the flexible hoses (15) and (25).
(g) Remove the nuts (33), the washers (34) and the bolts (36). Remove the block assemblies (35).
(h) Remove the nuts (40), the washers (39) and the bolts (37). Remove the guide blocks (38).
(i) Disconnect the unions (21) and (71) and remove the flexible hose (22).
(j) Disconnect the unions (24) and (72) and remove the flexible hose (23).
(k) Disconnect the unions (9) and (74) and remove the flexible hose (8).
(l) Disconnect the unions (11) and (75) and remove the flexible hose (10).
(m) Disconnect the union (30) and remove the flexible hose (29).
(n) Disconnect the union (31) and remove the flexible hose (32).
(o) Disconnect the union (59) and remove the flexible hose (66).
(p) Disconnect the union (60) and remove the flexible hose (65).
(3) To remove the rigid hydraulic pipes, do the steps that follow:
(a) Remove and discard the lockwire from the band clamp nuts (91).
(b) Loosen the band clamp nuts (91) sufficiently to remove the band clamps (92) from the line support blocks.
1 Make sure that the mystic tape and the line support blocks stay in position when the band clamps (92) are removed.
(c) Disconnect the unions (67) and (79) and remove the pipe (68).
(d) Disconnect the unions (70) and (78) and remove the pipe (69).
(e) Disconnect the union (77) and remove the nut (57). Remove the pipe (56).
(f) Disconnect the union (80) and remove the nut (58). Remove the pipe (55).
(g) Remove the nut (76) and disconnect the union (64). Remove the pipe (63).
(h) Remove the nut (73) and disconnect the union (61). Remove the pipe (62).
Subtask 32-11-12-020-050-K ** ON A/C NOT FOR ALL
MLG Hydraulic Dressings (MLG with Four-Piece Hydraulic Transfer-Block Assembly) ** ON A/C NOT FOR ALL
(1) Install a PLUG - BLANKING immediately after you remove the applicable flexible hydraulic hoses and the rigid pipes.
(2) To remove the flexible hydraulic hoses, do the steps that follow:
(a) Remove and discard the lockwire from the unions (1), (13), (14) and (26).
(b) Loosen the unions (1), (13), (14) and (26) to let the hydraulic fluid drain.
(c) Remove the nuts (7), the washers (6), the bolts (3), the washers (4) and the line-support block assemblies (5).
(d) Disconnect the unions (1) and (13).
(e) Remove the flexible hoses (2) and (12).
(f) Remove the nuts (18), the washers (19), the bolts (16), the washers (17) and the line-support block assemblies (20).
(g) Disconnect the unions (14) and (26).
(h) Remove the flexible hoses (15) and (25).
(i) Remove the nuts (33), the washers (34) and (36) and the bolts (37).
(j) Remove the block assemblies (35).
(k) Remove the nuts (43), the washers (42) and the bolts (40).
(l) Remove the guide blocks (41).
(m) Disconnect the unions (21) and (71) and remove the flexible hose (22).
(n) Disconnect the unions (24) and (72) and remove the flexible hose (23).
(o) Disconnect the unions (9) and (74) and remove the flexible hose (8).
(p) Disconnect the unions (11) and (75) and remove the flexible hose (10).
(q) Disconnect the union (30) and remove the flexible hose (29).
(r) Disconnect the union (31) and remove the flexible hose (32).
(s) Disconnect the union (59) and remove the flexible hose (66).
(t) Disconnect the union (60) and remove the flexible hose (65).
(3) To remove the rigid hydraulic pipes, do the steps that follow:
(a) Remove and discard the lockwire from the band clamp nuts (91).
(b) Loosen the band clamp nuts (91) sufficiently to remove the band clamps (92) from the line support blocks.
1 Make sure that the mystic tape and the line support blocks stay in position when the band clamps (92) are removed.
(c) Disconnect the unions (67) and (79) and remove the pipe (68).
(d) Disconnect the unions (70) and (78) and remove the pipe (69).
(e) Disconnect the union (77) and remove the nut (57) and the pipe (56).
(f) Disconnect the union (80) and remove the nut (58) and the pipe (55).
(g) Remove the nut (76) and disconnect the union (64). Remove the pipe (63).
(h) Remove the nut (73) and disconnect the union (61). Remove the pipe (62).
Subtask 32-11-12-020-055-A
(1) Install a PLUG - BLANKING immediately after you remove the applicable flexible hydraulic hoses and the rigid pipes.
(2) To remove the flexible hydraulic hoses, do the steps that follow:
(a) Remove and discard the lockwire from the unions (1), (13), (14) and (26).
(b) Loosen the unions (1), (13), (14) and (26) to let the hydraulic fluid drain.
(c) Remove the nuts (7), the washers (6), the bolts (3), the washers (4) and the line-support block assemblies (5).
(d) Disconnect the unions (1) and (13).
(e) Remove the flexible hoses (2) and (12).
(f) Remove the nuts (18), the washers (19), the bolts (16), the washers (17) and the line-support block assemblies (20).
(g) Disconnect the unions (14) and (26).
(h) Remove the flexible hoses (15) and (25).
(i) Remove the nuts (33), the washers (34) and (36) and the bolts (37).
(j) Remove the block assemblies (35).
(k) Remove the nuts (43), the washers (42) and the bolts (40).
(l) Remove the guide blocks (41).
(m) Disconnect the unions (21) and (71) and remove the flexible hose (22).
(n) Disconnect the unions (24) and (72) and remove the flexible hose (23).
(o) Disconnect the unions (9) and (74) and remove the flexible hose (8).
(p) Disconnect the unions (11) and (75) and remove the flexible hose (10).
(q) Disconnect the unions (30) and remove the flexible hose (29).
(r) Disconnect the union (31) and remove the flexible hose (32).
(s) Disconnect the union (59) and remove the flexible hose (66).
(t) Disconnect the union (60) and remove the flexible hose (65).
(3) To remove the rigid hydraulic pipes, do the steps that follow:
(a) Remove and discard the lockwire from the band clamp nuts (91).
(b) Loosen the band clamp nuts (91) sufficiently to remove the band clamps (92) from the line support blocks.
1 Make sure that the mystic tape and the line support blocks stay in position when the band clamps (92) are removed.
(c) Disconnect the unions (67) and (79) and remove the pipe (68).
(d) Disconnect the unions (70) and (78) and remove the pipe (69).
(e) Disconnect the union (77) and remove the nut (57) and the pipe (56).
(f) Disconnect the union (80) and remove the nut (58) and the pipe (55).
(g) Remove the nut (76) and disconnect the union (64). Remove the pipe (63).
(h) Remove the nut (73) and disconnect the union (61). Remove the pipe (62).
[Rev.10 from 2021]
2026.04.01 00:40:02 UTC
Removal of the MLG Hydraulic Dressings
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | 2 | CONTAINER 1 L (1/4 USGAL) |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 731 | L.H MAIN GEAR |
| 741 | R.H MAIN GEAR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 29-00-00-864-001-A | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
| TASK 29-00-00-910-002-A | Safety Procedures of the Hydraulic System |
| TASK 29-10-00-864-002-A | Depressurize the Yellow Hydraulic System |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
| TASK 29-23-00-860-001-A | Disconnection of the Isolation Coupling of the Power Transfer Unit (PTU) |
| TASK 32-00-00-481-001-A | Installation of the Safety Devices on the Landing Gears |
| TASK 32-00-00-860-001-A | Flight Configuration Precautions with Electrical Power |
| TASK 32-00-00-860-001-A-01 | Flight Configuration Precautions without Electrical Power |
| TASK 32-11-11-000-001-A | Removal of the MLG Leg Assembly |
| TASK 32-42-27-000-001-A | Removal of the Brake |
MLG Hydraulic Dressings (MLG with Four-Piece Hydraulic Transfer-Block Assembly) ** ON A/C NOT FOR ALL | |
MLG Hydraulic Dressings (MLG with Four-Piece Hydraulic Transfer-Block Assembly) ** ON A/C NOT FOR ALL | |
MLG Hydraulic Dressings (MLG with Four-Piece Hydraulic Transfer-Block Assembly) ** ON A/C NOT FOR ALL | |
Subtask 32-11-12-941-053-A
A. Safety Precautions
(1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(2) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002).
(3) Make sure that the ground safety locks are on the landing gear (Ref. AMM TASK 32-00-00-481-001).
(4) On panel 400VU:
Subtask 32-11-12-860-053-A (1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(2) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002).
(3) Make sure that the ground safety locks are on the landing gear (Ref. AMM TASK 32-00-00-481-001).
(4) On panel 400VU:
- Make sure that the landing-gear control-lever 6GA is in the DOWN position
- Put a WARNING NOTICE(S) in position to tell persons not to operate the landing gear.
B. Aircraft Maintenance Configuration
(1) Disconnect the isolation coupling of the PTU (Ref. AMM TASK 29-23-00-860-001).
(2) Make sure that the Yellow and Green hydraulic systems are depressurized (Ref. AMM TASK 29-00-00-864-001) and (Ref. AMM TASK 29-10-00-864-002).
(3) Depressurize the Green and Yellow hydraulic reservoirs (Ref. AMM TASK 29-14-00-614-001).
(4) If the electrical power is not necessary for other maintenance tasks, de-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002). Then, it is not necessary to operate the LGCIU circuit breakers.
(5) If the electrical power is necessary, do the precautions for flight configuration (Ref. AMM TASK 32-00-00-860-001) before you open the LGCIU circuit breakers.
Subtask 32-11-12-865-050-A (1) Disconnect the isolation coupling of the PTU (Ref. AMM TASK 29-23-00-860-001).
(2) Make sure that the Yellow and Green hydraulic systems are depressurized (Ref. AMM TASK 29-00-00-864-001) and (Ref. AMM TASK 29-10-00-864-002).
(3) Depressurize the Green and Yellow hydraulic reservoirs (Ref. AMM TASK 29-14-00-614-001).
(4) If the electrical power is not necessary for other maintenance tasks, de-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002). Then, it is not necessary to operate the LGCIU circuit breakers.
(5) If the electrical power is necessary, do the precautions for flight configuration (Ref. AMM TASK 32-00-00-860-001) before you open the LGCIU circuit breakers.
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 32-11-12-010-050-D ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | L/G/LGCIU/SYS1/NORM | 1GA | C09 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | LGCIU/BAT SPLY/SYS2 | 59GA | R33 |
| 121VU | LGCIU/BAT SPLY/SYS1 | 58GA | R32 |
| ** ON A/C ALL | |||
| 121VU | HYDRAULIC/BRAKING AND STEERING/SYS2/SPLY | 4GG | M36 |
| 121VU | HYDRAULIC/BRAKING AND STEERING/SYS2/CTL | 3GG | M35 |
| 121VU | HYDRAULIC/BRAKING AND STEERING/SYS1/CTL | 1GG | M34 |
| 121VU | HYDRAULIC/PARK BRK/CTL/STBY | 71GG | N37 |
| 121VU | HYDRAULIC/PARK BRK/CTL/NORM | 70GG | N36 |
| 121VU | HYDRAULIC/LGCIU/SYS2 | 2GA | Q35 |
| 121VU | HYDRAULIC/LGCIU/SYS1/GRND SPLY | 52GA | Q34 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | LGCIU/BAT SPLY/SYS2 | 59GA | R32 |
| 121VU | LGCIU/BAT SPLY/SYS1 | 58GA | R31 |
D. Get Access
MLG Hydraulic Dressings (MLG with Four-Piece Hydraulic Transfer-Block Assembly) ** ON A/C NOT FOR ALL
Put the ACCESS PLATFORM 2M (6 FT) in position at the applicable zone 731(741).
(2) Put the 2 CONTAINER 1 L (1/4 USGAL) below the unions (1), (14), (15) and (28).
(3) Disconnect the hydraulic hoses (29), (32), (65) and (66) at the MLG/airframe interface (Ref. AMM TASK 32-11-11-000-001).
(4) Disconnect the applicable hydraulic hoses at the MLG/wheel brake interface (Ref. AMM TASK 32-42-27-000-001).
(5) Put the PLUG-BLANKING in each disconnected line end.
Subtask 32-11-12-010-050-F ** ON A/C NOT FOR ALL WARNING:
DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
- FLUSH IT AWAY WITH CLEAN WATER
- GET MEDICAL AID.
CAUTION:
MAKE SURE THAT THE FLUID DOES NOT STAY ON THE AIRCRAFT STRUCTURE. IF THE FLUID GETS ON THE AIRCRAFT STRUCTURE, WASH IT OFF IMMEDIATELY WITH SOAP AND WATER.
(1)
MLG Hydraulic Dressings (MLG with Four-Piece Hydraulic Transfer-Block Assembly) ** ON A/C NOT FOR ALL Put the ACCESS PLATFORM 2M (6 FT) in position at the applicable zone 731(741).
(2) Put the 2 CONTAINER 1 L (1/4 USGAL) below the unions (1), (14), (15) and (28).
(3) Disconnect the hydraulic hoses (29), (32), (65) and (66) at the MLG/airframe interface (Ref. AMM TASK 32-11-11-000-001).
(4) Disconnect the applicable hydraulic hoses at the MLG/wheel brake interface (Ref. AMM TASK 32-42-27-000-001).
(5) Put the PLUG-BLANKING in each disconnected line end.
D. Get Access
MLG Hydraulic Dressings (MLG with Four-Piece Hydraulic Transfer-Block Assembly) ** ON A/C NOT FOR ALL
MLG Hydraulic Dressings (MLG with Four-Piece Hydraulic Transfer-Block Assembly) ** ON A/C NOT FOR ALL
MLG Hydraulic Dressings (MLG with One-Piece Hydraulic Transfer-Block Assembly) ** ON A/C NOT FOR ALL
Put the ACCESS PLATFORM 2M (6 FT) in position at the applicable zone 731(741).
(2) Put the CONTAINER 1 L (1/4 USGAL) below the unions (1), (13), (14) and (26).
(3) Disconnect the hydraulic hoses (29), (32), (65) and (66) at the MLG/airframe interface (Ref. AMM TASK 32-11-11-000-001).
(4) Disconnect the applicable hydraulic hoses at the MLG/wheel brake interface (Ref. AMM TASK 32-42-27-000-001).
(5) Put the PLUG-BLANKING in each disconnected line end.
4. ProcedureWARNING:
DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
- FLUSH IT AWAY WITH CLEAN WATER
- GET MEDICAL AID.
CAUTION:
MAKE SURE THAT THE FLUID DOES NOT STAY ON THE AIRCRAFT STRUCTURE. IF THE FLUID GETS ON THE AIRCRAFT STRUCTURE, WASH IT OFF IMMEDIATELY WITH SOAP AND WATER.
(1)
MLG Hydraulic Dressings (MLG with Four-Piece Hydraulic Transfer-Block Assembly) ** ON A/C NOT FOR ALL
MLG Hydraulic Dressings (MLG with Four-Piece Hydraulic Transfer-Block Assembly) ** ON A/C NOT FOR ALL
MLG Hydraulic Dressings (MLG with One-Piece Hydraulic Transfer-Block Assembly) ** ON A/C NOT FOR ALL (2) Put the CONTAINER 1 L (1/4 USGAL) below the unions (1), (13), (14) and (26).
(3) Disconnect the hydraulic hoses (29), (32), (65) and (66) at the MLG/airframe interface (Ref. AMM TASK 32-11-11-000-001).
(4) Disconnect the applicable hydraulic hoses at the MLG/wheel brake interface (Ref. AMM TASK 32-42-27-000-001).
(5) Put the PLUG-BLANKING in each disconnected line end.
Subtask 32-11-12-020-050-F ** ON A/C NOT FOR ALL
WARNING:
DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
- FLUSH IT AWAY WITH CLEAN WATER
- GET MEDICAL AID.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
WARNING:
USE PROTECTIVE GOGGLES WHEN YOU REMOVE OR INSTALL A COTTER PIN. EACH TIME YOU REMOVE A COTTER PIN DURING THE TASK, DISCARD IT IMMEDIATELY. A LOOSE COTTER PIN CAN CUT YOU OR MAKE YOU BLIND.
CAUTION:
MAKE SURE THAT THE FLUID DOES NOT STAY ON THE AIRCRAFT STRUCTURE. IF THE FLUID GETS ON THE AIRCRAFT STRUCTURE, WASH IT OFF IMMEDIATELY WITH SOAP AND WATER.
A. Removal of the MLG Hydraulic Dressings (MLG with the Four-Piece Hydraulic Transfer-Block Assembly)
MLG Hydraulic Dressings (MLG with Four-Piece Hydraulic Transfer-Block Assembly) ** ON A/C NOT FOR ALL (2) To remove the flexible hydraulic hoses, do the steps that follow:
(a) If necessary, remove and discard the lockwire from the unions (1), (14), (15) and (28).
(b) Loosen the unions (1), (14), (15) and (28) to let the hydraulic fluid drain.
(c) If the cotter pins (8) are installed, remove and discard them.
(d) Remove the nuts (7), the washers (6), the bolts (3), the washers (4) and the block assemblies (5).
(e) Disconnect the unions (1) and (14). Remove the flexible hoses (2) and (13).
(f) If the cotter pins (19) are installed, remove and discard them.
(g) Remove the nuts (20), the washers (21), the bolts (17), the washers (18) and the block assemblies (22).
(h) Disconnect the unions (15) and (28). Remove the flexible hoses (16) and (27).
(i) Remove the nuts (33), the washers (34) and the bolts (36). Remove the block assemblies (35).
(j) Remove and discard the cotter pin (41).
(k) Remove the nuts (40), the washers (39) and the bolts (37). Remove the channels (38).
(l) Disconnect the unions (23) and (71) and remove the flexible hose (24).
(m) Disconnect the unions (26) and (72) and remove the flexible hose (25).
(n) Disconnect the unions (10) and (74) and remove the flexible hose (9).
(o) Disconnect the unions (12) and (75) and remove the flexible hose (11)
(p) Disconnect the union (30) and remove the flexible hose (29).
(q) Disconnect the union (31) and remove the flexible hose (32).
(r) Disconnect the union (59) and remove the flexible hose (66).
(s) Disconnect the union (60) and remove the flexible hose (65).
(3) To remove the rigid hydraulic pipes, do the steps that follow:
(a) Remove and discard the lockwire from the band-clamp nuts (91).
(b) Loosen the nuts (91) sufficiently to remove the band-clamps (92) from the line support blocks.
1 Make sure that the mystic tape and the blocks stay in position when the band-clamps (92) are removed.
(c) Disconnect the unions (67) and (79) and remove the pipe (68).
(d) Disconnect the unions (70) and (78) and remove the pipe (69).
(e) Disconnect the union (77) and remove the locknut (57). Remove the pipe (56).
(f) Disconnect the union (80) and remove the locknut (58). Remove the pipe (55).
(g) Remove the locknut (76) and disconnect the union (64). Remove the pipe (63).
(h) Remove the locknut (73) and disconnect the union (61). Remove the pipe (62).
WARNING:
DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
- FLUSH IT AWAY WITH CLEAN WATER
- GET MEDICAL AID.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
CAUTION:
MAKE SURE THAT THE FLUID DOES NOT STAY ON THE AIRCRAFT STRUCTURE. IF THE FLUID GETS ON THE AIRCRAFT STRUCTURE, WASH IT OFF IMMEDIATELY WITH SOAP AND WATER.
A. Removal of the MLG Hydraulic Dressings (MLG with the Four-Piece Hydraulic Transfer-Block Assembly)
MLG Hydraulic Dressings (MLG with Four-Piece Hydraulic Transfer-Block Assembly) ** ON A/C NOT FOR ALL (2) To remove the flexible hydraulic hoses, do the steps that follow:
(a) Remove and discard the lockwire from the unions (1), (13), (14) and (26).
(b) Loosen the unions (1), (13), (14) and (26) to let the hydraulic fluid drain.
(c) Remove the nuts (7), the washers (6), the bolts (3), the washers (4) and the line-support block assemblies (5).
(d) Disconnect the unions (1) and (13). Remove the flexible hoses (2) and (12).
(e) Remove the nuts (18), the washers (19), the bolts (16), the washers (17) and the line-support block assemblies (20).
(f) Disconnect the unions (14) and (26). Remove the flexible hoses (15) and (25).
(g) Remove the nuts (33), the washers (34) and the bolts (36). Remove the block assemblies (35).
(h) Remove the nuts (40), the washers (39) and the bolts (37). Remove the guide blocks (38).
(i) Disconnect the unions (21) and (71) and remove the flexible hose (22).
(j) Disconnect the unions (24) and (72) and remove the flexible hose (23).
(k) Disconnect the unions (9) and (74) and remove the flexible hose (8).
(l) Disconnect the unions (11) and (75) and remove the flexible hose (10).
(m) Disconnect the union (30) and remove the flexible hose (29).
(n) Disconnect the union (31) and remove the flexible hose (32).
(o) Disconnect the union (59) and remove the flexible hose (66).
(p) Disconnect the union (60) and remove the flexible hose (65).
(3) To remove the rigid hydraulic pipes, do the steps that follow:
(a) Remove and discard the lockwire from the band clamp nuts (91).
(b) Loosen the band clamp nuts (91) sufficiently to remove the band clamps (92) from the line support blocks.
1 Make sure that the mystic tape and the line support blocks stay in position when the band clamps (92) are removed.
(c) Disconnect the unions (67) and (79) and remove the pipe (68).
(d) Disconnect the unions (70) and (78) and remove the pipe (69).
(e) Disconnect the union (77) and remove the nut (57). Remove the pipe (56).
(f) Disconnect the union (80) and remove the nut (58). Remove the pipe (55).
(g) Remove the nut (76) and disconnect the union (64). Remove the pipe (63).
(h) Remove the nut (73) and disconnect the union (61). Remove the pipe (62).
WARNING:
DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
- FLUSH IT AWAY WITH CLEAN WATER
- GET MEDICAL AID.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
CAUTION:
MAKE SURE THAT THE FLUID DOES NOT STAY ON THE AIRCRAFT STRUCTURE. IF THE FLUID GETS ON THE AIRCRAFT STRUCTURE, WASH IT OFF IMMEDIATELY WITH SOAP AND WATER.
A. Removal of the MLG Hydraulic Dressings (MLG with the Four-Piece Hydraulic Transfer-Block Assembly)
MLG Hydraulic Dressings (MLG with Four-Piece Hydraulic Transfer-Block Assembly) ** ON A/C NOT FOR ALL (2) To remove the flexible hydraulic hoses, do the steps that follow:
(a) Remove and discard the lockwire from the unions (1), (13), (14) and (26).
(b) Loosen the unions (1), (13), (14) and (26) to let the hydraulic fluid drain.
(c) Remove the nuts (7), the washers (6), the bolts (3), the washers (4) and the line-support block assemblies (5).
(d) Disconnect the unions (1) and (13).
(e) Remove the flexible hoses (2) and (12).
(f) Remove the nuts (18), the washers (19), the bolts (16), the washers (17) and the line-support block assemblies (20).
(g) Disconnect the unions (14) and (26).
(h) Remove the flexible hoses (15) and (25).
(i) Remove the nuts (33), the washers (34) and (36) and the bolts (37).
(j) Remove the block assemblies (35).
(k) Remove the nuts (43), the washers (42) and the bolts (40).
(l) Remove the guide blocks (41).
(m) Disconnect the unions (21) and (71) and remove the flexible hose (22).
(n) Disconnect the unions (24) and (72) and remove the flexible hose (23).
(o) Disconnect the unions (9) and (74) and remove the flexible hose (8).
(p) Disconnect the unions (11) and (75) and remove the flexible hose (10).
(q) Disconnect the union (30) and remove the flexible hose (29).
(r) Disconnect the union (31) and remove the flexible hose (32).
(s) Disconnect the union (59) and remove the flexible hose (66).
(t) Disconnect the union (60) and remove the flexible hose (65).
(3) To remove the rigid hydraulic pipes, do the steps that follow:
(a) Remove and discard the lockwire from the band clamp nuts (91).
(b) Loosen the band clamp nuts (91) sufficiently to remove the band clamps (92) from the line support blocks.
1 Make sure that the mystic tape and the line support blocks stay in position when the band clamps (92) are removed.
(c) Disconnect the unions (67) and (79) and remove the pipe (68).
(d) Disconnect the unions (70) and (78) and remove the pipe (69).
(e) Disconnect the union (77) and remove the nut (57) and the pipe (56).
(f) Disconnect the union (80) and remove the nut (58) and the pipe (55).
(g) Remove the nut (76) and disconnect the union (64). Remove the pipe (63).
(h) Remove the nut (73) and disconnect the union (61). Remove the pipe (62).
WARNING:
DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
- FLUSH IT AWAY WITH CLEAN WATER
- GET MEDICAL AID.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
CAUTION:
MAKE SURE THAT THE FLUID DOES NOT STAY ON THE AIRCRAFT STRUCTURE. IF THE FLUID GETS ON THE AIRCRAFT STRUCTURE, WASH IT OFF IMMEDIATELY WITH SOAP AND WATER.
B. Removal of the MLG Hydraulic Dressings (MLG with the One-Piece Hydraulic Transfer-Block Assembly)(1) Install a PLUG - BLANKING immediately after you remove the applicable flexible hydraulic hoses and the rigid pipes.
(2) To remove the flexible hydraulic hoses, do the steps that follow:
(a) Remove and discard the lockwire from the unions (1), (13), (14) and (26).
(b) Loosen the unions (1), (13), (14) and (26) to let the hydraulic fluid drain.
(c) Remove the nuts (7), the washers (6), the bolts (3), the washers (4) and the line-support block assemblies (5).
(d) Disconnect the unions (1) and (13).
(e) Remove the flexible hoses (2) and (12).
(f) Remove the nuts (18), the washers (19), the bolts (16), the washers (17) and the line-support block assemblies (20).
(g) Disconnect the unions (14) and (26).
(h) Remove the flexible hoses (15) and (25).
(i) Remove the nuts (33), the washers (34) and (36) and the bolts (37).
(j) Remove the block assemblies (35).
(k) Remove the nuts (43), the washers (42) and the bolts (40).
(l) Remove the guide blocks (41).
(m) Disconnect the unions (21) and (71) and remove the flexible hose (22).
(n) Disconnect the unions (24) and (72) and remove the flexible hose (23).
(o) Disconnect the unions (9) and (74) and remove the flexible hose (8).
(p) Disconnect the unions (11) and (75) and remove the flexible hose (10).
(q) Disconnect the unions (30) and remove the flexible hose (29).
(r) Disconnect the union (31) and remove the flexible hose (32).
(s) Disconnect the union (59) and remove the flexible hose (66).
(t) Disconnect the union (60) and remove the flexible hose (65).
(3) To remove the rigid hydraulic pipes, do the steps that follow:
(a) Remove and discard the lockwire from the band clamp nuts (91).
(b) Loosen the band clamp nuts (91) sufficiently to remove the band clamps (92) from the line support blocks.
1 Make sure that the mystic tape and the line support blocks stay in position when the band clamps (92) are removed.
(c) Disconnect the unions (67) and (79) and remove the pipe (68).
(d) Disconnect the unions (70) and (78) and remove the pipe (69).
(e) Disconnect the union (77) and remove the nut (57) and the pipe (56).
(f) Disconnect the union (80) and remove the nut (58) and the pipe (55).
(g) Remove the nut (76) and disconnect the union (64). Remove the pipe (63).
(h) Remove the nut (73) and disconnect the union (61). Remove the pipe (62).