Upload Procedure and Part Number Verification of the Loadable Software Parts (LSP) in the Wireless Ground Link-Digital Access Recorder (WGL-DAR)
TASK 31-36-00-710-803-A
Upload Procedure and Part Number Verification of the Loadable Software Parts (LSP) in the Wireless Ground Link-Digital Access Recorder (WGL-DAR)
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 31-36-00-861-090-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-710-148-A ** ON A/C NOT FOR ALL
Subtask 31-36-00-860-154-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 08:36:21 UTC
Upload Procedure and Part Number Verification of the Loadable Software Parts (LSP) in the Wireless Ground Link-Digital Access Recorder (WGL-DAR)
CAUTION:
OBEY THESE PRECAUTIONS TO PREVENT ELECTROSTATIC DISCHARGE (ESD) DAMAGE TO THE COMPONENTS:
- STAY ON A CONDUCTIVE SURFACE THAT IS ELECTRICALLY GROUNDED.
- USE A CONDUCTIVE WRIST-STRAP THAT IS ELECTRICALLY GROUNDED. (CONNECTED TO A BONDING-POINT NEAR THE WORK AREA).
- BEFORE YOU USE THE TOOLS, MOMENTARILY HOLD THEM AGAINST AN ELECTRICAL GROUND TO RELEASE STATIC ELECTRICITY.
NOTE: You can use different vendor-supplied methods (for example, CF card) as an alternative procedure to upload the software in the WGL-DAR. VSB 2243800-31-27 contains the vendor instructions to do this software upload.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121 | AVIONICS COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
| TASK 31-36-00-00-02 | AIDS INTERCONNECTION (DMU, DAR) - DESCRIPTION AND OPERATION |
Subtask 31-36-00-861-090-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 31-36-00-010-100-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
B. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position, below access door 824.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
(3) For the location of the WGL-DAR, refer to paragraph Component Location (Ref. AMM D/O 31-36-00-00).
Subtask 31-36-00-865-180-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position, below access door 824.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
(3) For the location of the WGL-DAR, refer to paragraph Component Location (Ref. AMM D/O 31-36-00-00).
C. Get access to the applicable 5000VE-series panel(s). Then open, safety and tag this(these) circuit breaker(s):
Subtask 31-36-00-480-056-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | RCDR/ACCLRM | 9TU | K18 |
| 121VU | AIDS & RCDR/FDIMU | 5TV | K15 |
D. Connection of the Portable Data Loader (PDL) / Standard Maintenance Laptop to the WGL-DAR
(1) On the front panel of the WGL-DAR, open the door to get access to the RJ-45 (Ethernet) port.
(2) Identify the RJ-45 (Ethernet) port.
(3) Connect the PDL/ Standard Maintenance Laptop with the Crossover Patch Cable to the RJ-45 (Ethernet) port on the WGL-DAR.
Subtask 31-36-00-860-153-A ** ON A/C NOT FOR ALL (1) On the front panel of the WGL-DAR, open the door to get access to the RJ-45 (Ethernet) port.
(2) Identify the RJ-45 (Ethernet) port.
(3) Connect the PDL/ Standard Maintenance Laptop with the Crossover Patch Cable to the RJ-45 (Ethernet) port on the WGL-DAR.
E. Start the PDL/ Standard Maintenance Laptop
(1) Start the PDL/ Standard Maintenance Laptop. Refer to the applicable user guide.
4. Procedure(1) Start the PDL/ Standard Maintenance Laptop. Refer to the applicable user guide.
Subtask 31-36-00-710-148-A ** ON A/C NOT FOR ALL
A. Part Number Verification of the Loadable Software Parts (LSP) of the Wireless Ground Link-Digital Access Recorder (WGL-DAR)
Subtask 31-36-00-710-147-A ** ON A/C NOT FOR ALL NOTE: This procedure lets you do a check of the part number(s) of the LSP, to make sure that you have the correct LSP. You can do the check of the part number on the WGL-DAR display.
(1) Before you start the procedure, you must make sure that you know the part number of the LSP that you installed in the WGL-DAR. NOTE: If you cannot find the LSP part number, contact the vendor customer services.
| ACTION | RESULT |
|---|---|
|
|
| 1.Make sure that this(these) circuit breaker(s) is(are) closed: [5TV] [9TU] |
|
| 2.Push the MODE button. |
|
| 3.Push the + button, again and again, until UNIT INFO comes into view. |
|
| 4.Push the SEL button. |
|
| 5.Push the + button, again and again, until S/W VERSION comes into view. |
|
| 6.Push the SEL button. |
|
| 7.Push the + or - button again and again, until other part numbers come into view. |
|
| 8.Do a check of the LSP part number on the display. NOTE: If other LSPs are installed, do again the previous 2 steps. | NOTE: Make sure that the part numbers of the OPS and AII are the same with the part numbers written on the software media. NOTE: You can have different configurations of the LSP part number on different A/Cs. If the LSP part number does not come into view or it is different than the one you know, contact the vendor customer services. |
| 9.Push the MODE button, again and again, until UNIT INFO comes into view. |
|
| 10.Push the + button, again and again, until SYSTEM STATE into view. |
|
B. Upload of the Loadable Software Parts (LSP) in the Wireless Ground Link-Digital Access Recorder (WGL-DAR) with PDL/ Laptop
5. Close-up| ACTION | RESULT |
|---|---|
| On the WGL-DAR front panel: | On the WGL-DAR display: |
| 1.Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): [5TV] [9TU] |
|
| 2.Make sure that RG-Interlock is off. |
|
| On the PDL/ Standard Maintenance Laptop: | |
| Upload the WGL-DAR software. Refer to the applicable user guide. | |
Subtask 31-36-00-860-154-A ** ON A/C NOT FOR ALL
A. Stop the PDL/ Standard Maintenance Laptop
(1) Stop the PDL/ Standard Maintenance Laptop. Refer to the applicable use guide.
Subtask 31-36-00-080-056-A ** ON A/C NOT FOR ALL (1) Stop the PDL/ Standard Maintenance Laptop. Refer to the applicable use guide.
B. Disconnection of the PDL/ Standard Maintenance Laptop from the WGL-DAR
(1) Disconnect the Crossover Patch Cable from the PDL/ Standard Maintenance Laptop and from the RJ-45 (Ethernet) port on the WGL-DAR.
Subtask 31-36-00-865-183-A ** ON A/C NOT FOR ALL (1) Disconnect the Crossover Patch Cable from the PDL/ Standard Maintenance Laptop and from the RJ-45 (Ethernet) port on the WGL-DAR.
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 31-36-00-410-098-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | RCDR/ACCLRM | 9TU | K18 |
| 121VU | AIDS & RCDR/FDIMU | 5TV | K15 |
D. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
Subtask 31-36-00-862-092-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
E. Aircraft Maintenance Configuration
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).