Installation of Temperature Sensor
TASK 30-73-19-400-001-A
Installation of Temperature Sensor
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 30-73-19-860-050-A ** ON A/C NOT FOR ALL
Subtask 30-73-19-420-050-A ** ON A/C NOT FOR ALL
Subtask 30-73-19-410-050-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 08:25:07 UTC
Installation of Temperature Sensor
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
NOTE: The installation procedure is the same for the temperature sensors 30DW, 40DW, 60DW, 61DW, 70DW, 90DW, 210DW.
ZONE: 150
ZONE: 160
ZONE: 170
FIN: 110DW ** ON A/C NOT FOR ALL
FIN: 30DW ** ON A/C NOT FOR ALL
FIN: 40DW ** ON A/C NOT FOR ALL
FIN: 60DW ** ON A/C NOT FOR ALL
FIN: 61DW ** ON A/C NOT FOR ALL
FIN: 70DW ** ON A/C NOT FOR ALL
FIN: 90DW ** ON A/C NOT FOR ALL
1. Reason for the JobZONE: 160
ZONE: 170
FIN: 110DW ** ON A/C NOT FOR ALL
FIN: 30DW ** ON A/C NOT FOR ALL
FIN: 40DW ** ON A/C NOT FOR ALL
FIN: 60DW ** ON A/C NOT FOR ALL
FIN: 61DW ** ON A/C NOT FOR ALL
FIN: 70DW ** ON A/C NOT FOR ALL
FIN: 90DW ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20 |
| No specific | AR | TIE WRAP(S) |
| FOR [110DW] (SENSOR,TEMPERATURE-) | ||
| FOR [40DW] (SENSOR,TEMPERATURE-) | ||
| FOR [70DW] (SENSOR,TEMPERATURE-) | ||
| FOR [90DW] (SENSOR,TEMPERATURE-) | ||
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| FOR [30DW] (SENSOR,TEMPERATURE-) | ||
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| FOR [40DW] (SENSOR,TEMPERATURE-) | ||
| FOR [61DW] (SENSOR,TEMPERATURE-) | ||
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| FOR [60DW] (SENSOR,TEMPERATURE-) | ||
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.05RAB9) | Adhesive Film Tape-- Aluminium Foil - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 150 | AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT |
| 160 | BULK CARGO COMPARTMENT AFT BULKHEAD OF AFT CARGO COMPARTMENT TO AFT BULKHEAD OF BULK CARGO COMPARTMENT |
| 170 | AFT CAB U/FLOOR COMPT AFT BHD OF BULK |
| FOR [110DW] (SENSOR,TEMPERATURE-) | |
| 151CW | |
| FOR [30DW] (SENSOR,TEMPERATURE-) | |
| 132PW | |
| 131NW | |
| FOR [40DW] (SENSOR,TEMPERATURE-) | |
| FOR [70DW] (SENSOR,TEMPERATURE-) | |
| 161CW, 162DW | |
| FOR [40DW] (SENSOR,TEMPERATURE-) | |
| FOR [61DW] (SENSOR,TEMPERATURE-) | |
| 161DW | |
| FOR [40DW] (SENSOR,TEMPERATURE-) | |
| FOR [70DW] (SENSOR,TEMPERATURE-) | |
| FOR [90DW] (SENSOR,TEMPERATURE-) | |
| 161CW, 161DW | |
| FOR [60DW] (SENSOR,TEMPERATURE-) | |
| 151BW | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 30-73-00-740-001-A | BITE Test of the Potable Water Ice-Protection |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| FOR [110DW] (SENSOR,TEMPERATURE-) | |
| TASK 25-55-11-000-003-A | Removal of the Sidewall Panels in the Aft Cargo Compartment - FR47/FR59 |
| TASK 25-55-11-400-003-A | Installation of the Sidewall Panels in the Aft Cargo Compartment - FR47/FR59 |
| FOR [110DW] (SENSOR,TEMPERATURE-) | |
| FOR [40DW] (SENSOR,TEMPERATURE-) | |
| FOR [70DW] (SENSOR,TEMPERATURE-) | |
| FOR [90DW] (SENSOR,TEMPERATURE-) | |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| FOR [30DW] | |
| TASK 25-54-12-000-001-A | Removal of the Forward Cargo-Compartment Partition |
| TASK 25-54-12-400-001-A | Installation of the Forward Cargo-Compartment Partition |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| FOR [40DW] (SENSOR,TEMPERATURE-) | |
| TASK 25-55-12-000-001-A | Removal of the Aft Cargo-Compartment Partition at FR65 |
| FOR [40DW] (SENSOR,TEMPERATURE-) | |
| FOR [70DW] (SENSOR,TEMPERATURE-) | |
| TASK 25-55-12-400-001-A | Installation of the Aft Cargo-Compartment Partition at FR65 |
| FOR [40DW] (SENSOR,TEMPERATURE-) | |
| FOR [61DW] (SENSOR,TEMPERATURE-) | |
| TASK 25-55-12-000-001-A | Removal of the Aft Cargo-Compartment Partition at FR65 |
| TASK 25-55-12-400-001-A | Installation of the Aft Cargo-Compartment Partition at FR65 |
| TASK 52-30-00-860-006-A | Open the Bulk Cargo-Compartment Door |
| TASK 52-30-00-860-008-A | Close the Bulk Cargo-Compartment Door |
| FOR [40DW] (SENSOR,TEMPERATURE-) | |
| FOR [70DW] (SENSOR,TEMPERATURE-) | |
| FOR [90DW] (SENSOR,TEMPERATURE-) | |
| TASK 25-55-12-000-001-A | Removal of the Aft Cargo-Compartment Partition at FR65 |
| TASK 25-55-12-000-003-A | Removal of the Sidewall Panels in the Aft Cargo Compartment - FR59/FR65 |
| TASK 25-55-12-400-001-A | Installation of the Aft Cargo-Compartment Partition at FR65 |
| TASK 25-55-12-400-003-A | Installation of the Sidewall Panels in the Aft Cargo Compartment - FR59/FR65 |
| FOR [60DW] | |
| TASK 25-55-11-000-001-A | Removal of the Aft Cargo-Compartment Partition at FR47 |
| TASK 25-55-11-400-001-A | Installation of the Aft Cargo-Compartment Partition at FR47 |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 30-73-19-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) FOR [30DW]
Subtask 30-73-19-860-050-B ** ON A/C NOT FOR ALL (1) FOR [30DW]
- Make sure that the FWD cargo-compartment door is open (Ref. AMM TASK 52-30-00-860-001).
- Make sure that the CARGO COMP LT switch 6LU is set to ON.
- Make sure that the partitions 131NW/132PW are removed (Ref. AMM TASK 25-54-12-000-001).
- Make sure that the AFT cargo-compartmnet door is open (Ref. AMM TASK 52-30-00-860-001) .
- Make sure that the CARGO COMP LT switch 8LU is set to ON.
- Make sure that the partition 151BW is removed (Ref. AMM TASK 25-55-11-000-001).
- Make sure that the BULK cargo-compartmenbt door is open (Ref. AMM D/O 52-30-00-86).
- Make sure that the CARGO COMP LT switch 8LU is set to ON.
- Make sure that the partition 162DW is removed (Ref. AMM TASK 25-55-12-000-001).
- Make sure that the BULK cargo-compartment door is open (Ref. AMM D/O 52-30-00-86).
- Make sure that the CARGO COMP LT switch 8LU is set to ON.
- Make sure that the sidewall panel 161BW is removed.
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) FOR [30DW] (SENSOR,TEMPERATURE-)
(a) Make sure that the forward cargo-compartment door is open (Ref. AMM TASK 52-30-00-860-001).
(b) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position.
(c) Make sure that the cargo-compartment light switch 6LU is set to ON.
(d) Make sure that partitions 131NW and 132PW are removed (Ref. AMM TASK 25-54-12-000-001).
(3) FOR [60DW] (SENSOR,TEMPERATURE-)
(a) Make sure that the aft cargo-compartment door is open (Ref. AMM TASK 52-30-00-860-001) .
(b) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position.
(c) Make sure that the cargo-compartment light switch 8LU is set to ON.
(d) Make sure that partition 151BW is removed (Ref. AMM TASK 25-55-11-000-001).
(4) FOR [40DW] (SENSOR,TEMPERATURE-), [61DW] (SENSOR,TEMPERATURE-)
(a) Make sure that the bulk cargo-compartment door is open (Ref. AMM TASK 52-30-00-860-006).
(b) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position.
(c) Make sure that the cargo-compartment light switch 8LU is set to ON.
(d) Make sure that partition 161DW is removed (Ref. AMM TASK 25-55-12-000-001).
Subtask 30-73-19-860-050-J ** ON A/C NOT FOR ALL (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) FOR [30DW] (SENSOR,TEMPERATURE-)
(a) Make sure that the forward cargo-compartment door is open (Ref. AMM TASK 52-30-00-860-001).
(b) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position.
(c) Make sure that the cargo-compartment light switch 6LU is set to ON.
(d) Make sure that partitions 131NW and 132PW are removed (Ref. AMM TASK 25-54-12-000-001).
(3) FOR [60DW] (SENSOR,TEMPERATURE-)
(a) Make sure that the aft cargo-compartment door is open (Ref. AMM TASK 52-30-00-860-001) .
(b) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position.
(c) Make sure that the cargo-compartment light switch 8LU is set to ON.
(d) Make sure that partition 151BW is removed (Ref. AMM TASK 25-55-11-000-001).
(4) FOR [40DW] (SENSOR,TEMPERATURE-), [61DW] (SENSOR,TEMPERATURE-)
(a) Make sure that the bulk cargo-compartment door is open (Ref. AMM TASK 52-30-00-860-006).
(b) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position.
(c) Make sure that the cargo-compartment light switch 8LU is set to ON.
(d) Make sure that partition 161DW is removed (Ref. AMM TASK 25-55-12-000-001).
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
(2) FOR [40DW] (SENSOR,TEMPERATURE-), [70DW] (SENSOR,TEMPERATURE-), [90DW] (SENSOR,TEMPERATURE-), [110DW] (SENSOR,TEMPERATURE-)
(a) Make sure that the aft cargo-compartment door is open (Ref. AMM TASK 52-30-00-860-001).
(b) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position.
(c) Make sure that the cargo-compartment light switch 8LU is set to ON position.
(3) FOR [40DW] (SENSOR,TEMPERATURE-), [70DW] (SENSOR,TEMPERATURE-), [90DW] (SENSOR,TEMPERATURE-)
(a) Make sure that partition 161DW and sidewall panel 161CW are removed (Ref. AMM TASK 25-55-12-000-001) (Ref. AMM TASK 25-55-12-000-003).
(4) FOR [110DW] (SENSOR,TEMPERATURE-)
(a) Make sure that sidewall panel 151CW is removed (Ref. AMM TASK 25-55-11-000-003).
Subtask 30-73-19-865-054-A ** ON A/C NOT FOR ALL (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
(2) FOR [40DW] (SENSOR,TEMPERATURE-), [70DW] (SENSOR,TEMPERATURE-), [90DW] (SENSOR,TEMPERATURE-), [110DW] (SENSOR,TEMPERATURE-)
(a) Make sure that the aft cargo-compartment door is open (Ref. AMM TASK 52-30-00-860-001).
(b) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position.
(c) Make sure that the cargo-compartment light switch 8LU is set to ON position.
(3) FOR [40DW] (SENSOR,TEMPERATURE-), [70DW] (SENSOR,TEMPERATURE-), [90DW] (SENSOR,TEMPERATURE-)
(a) Make sure that partition 161DW and sidewall panel 161CW are removed (Ref. AMM TASK 25-55-12-000-001) (Ref. AMM TASK 25-55-12-000-003).
(4) FOR [110DW] (SENSOR,TEMPERATURE-)
(a) Make sure that sidewall panel 151CW is removed (Ref. AMM TASK 25-55-11-000-003).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | POT/WASTE WIP-HEATER-LINE | 21DW | A03 |
| 2000VU | POT/WASTE WIP-HEATER-CTL | 2DW | A01 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | POT WIP-HEATER-LINE | 21DW | A03 |
| 2000VU | POT WIP-HEATER-CTL | 2DW | A01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | POT/WASTE WIP-HEATER-LINE | 51DW | D04 |
| 2001VU | POT/WASTE WIP-HEATER-LINE | 31DW | D03 |
| 2001VU | POT/WASTE WIP-HEATER-CTL | 32DW | D02 |
Subtask 30-73-19-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Temperature Sensor
(1) Clean the component interfaces and the adjacent area.
(2) Install the clamp sensor assembly (3) and the clamp (4) on the water line (5) with the screws (1).
(3) Make sure that the clamp sensor assembly (3) and the clamp (4) are tightly installed on the water line (5).
(5) Install the insulation (6) around the clamp (4) and the clamp sensor assembly (3).
(6) Attach the longitudinal seam of the insulation (6) with Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) (7).
(7) Attach the electrical wires with TIE WRAP(S) on the water line (5).
(8) Make sure that the cable ties do not compress the insulation (6).
Subtask 30-73-19-865-056-A ** ON A/C NOT FOR ALL (1) Clean the component interfaces and the adjacent area.
(2) Install the clamp sensor assembly (3) and the clamp (4) on the water line (5) with the screws (1).
(3) Make sure that the clamp sensor assembly (3) and the clamp (4) are tightly installed on the water line (5).
CAUTION:
REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU CONNECT THE ELECTRICAL WIRES.
INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
(4) Connect the electrical connections (2) with an ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20. (5) Install the insulation (6) around the clamp (4) and the clamp sensor assembly (3).
(6) Attach the longitudinal seam of the insulation (6) with Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) (7).
(7) Attach the electrical wires with TIE WRAP(S) on the water line (5).
(8) Make sure that the cable ties do not compress the insulation (6).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 30-73-19-740-050-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | POT/WASTE WIP-HEATER-LINE | 21DW | A03 |
| 2000VU | POT/WASTE WIP-HEATER-CTL | 2DW | A01 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | POT WIP-HEATER-LINE | 21DW | A03 |
| 2000VU | POT WIP-HEATER-CTL | 2DW | A01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | POT/WASTE WIP-HEATER-LINE | 51DW | D04 |
| 2001VU | POT/WASTE WIP-HEATER-LINE | 31DW | D03 |
| 2001VU | POT/WASTE WIP-HEATER-CTL | 32DW | D02 |
Subtask 30-73-19-410-050-B ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) FOR [30DW] (SENSOR,TEMPERATURE-)
(a) Install the partition 131NW (Ref. AMM TASK 25-54-12-400-001).
(b) Set the CARGO COMP LT switch 6LU to OFF.
(c) Close the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
(3) FOR [60DW] (SENSOR,TEMPERATURE-)
(a) Install the partition 151BW (Ref. AMM TASK 25-55-11-400-001).
(b) Set the CARGO COMP LT switch 8LU to OFF.
(c) Close the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
(4) FOR [40DW] (SENSOR,TEMPERATURE-), [61DW] (SENSOR,TEMPERATURE-)
(a) Install the partition 161DW (Ref. AMM TASK 25-55-12-400-001).
(b) Set the CARGO COMP LT switch 8LU to OFF.
(c) Close the BULK cargo-compartment door (Ref. AMM TASK 52-30-00-860-008).
Subtask 30-73-19-410-050-D ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) FOR [30DW] (SENSOR,TEMPERATURE-)
(a) Install the partition 131NW (Ref. AMM TASK 25-54-12-400-001).
(b) Set the CARGO COMP LT switch 6LU to OFF.
(c) Close the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
(3) FOR [60DW] (SENSOR,TEMPERATURE-)
(a) Install the partition 151BW (Ref. AMM TASK 25-55-11-400-001).
(b) Set the CARGO COMP LT switch 8LU to OFF.
(c) Close the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
(4) FOR [40DW] (SENSOR,TEMPERATURE-), [61DW] (SENSOR,TEMPERATURE-)
(a) Install the partition 161DW (Ref. AMM TASK 25-55-12-400-001).
(b) Set the CARGO COMP LT switch 8LU to OFF.
(c) Close the BULK cargo-compartment door (Ref. AMM TASK 52-30-00-860-008).
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) FOR [30DW]
Subtask 30-73-19-410-050-J ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) FOR [30DW]
- Install the partition 131NW (Ref. AMM TASK 25-54-12-400-001).
- Set the CARGO COMP LT switch 6LU to OFF.
- Close the FWD cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
- Install the partition 161CW 162DW (Ref. AMM TASK 25-55-12-400-001).
- Set the CARGO COMP LT switch 8LU to OFF.
- Close the BULK cargo-compartment door (Ref. AMM D/O 52-30-00-86).
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) FOR [90DW] (SENSOR,TEMPERATURE-), [40DW] (SENSOR,TEMPERATURE-), [70DW] (SENSOR,TEMPERATURE-)
(a) Install partition 161DW (Ref. AMM TASK 25-55-12-400-001) and sidewall panel 161CW (Ref. AMM TASK 25-55-12-400-003).
(3) FOR [110DW] (SENSOR,TEMPERATURE-)
(a) Install sidewall panel 151CW (Ref. AMM TASK 25-55-11-400-003).
(4) Set the cargo-compartment light switch 8LU to OFF position.
(5) Remove the access platform(s).
(6) Close the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
Subtask 30-73-19-862-050-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) FOR [90DW] (SENSOR,TEMPERATURE-), [40DW] (SENSOR,TEMPERATURE-), [70DW] (SENSOR,TEMPERATURE-)
(a) Install partition 161DW (Ref. AMM TASK 25-55-12-400-001) and sidewall panel 161CW (Ref. AMM TASK 25-55-12-400-003).
(3) FOR [110DW] (SENSOR,TEMPERATURE-)
(a) Install sidewall panel 151CW (Ref. AMM TASK 25-55-11-400-003).
(4) Set the cargo-compartment light switch 8LU to OFF position.
(5) Remove the access platform(s).
(6) Close the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
Removal of Temperature Sensor 40DW and 70DW