Deactivation of the Window Heat Computer (WHC)


TASK 30-42-00-040-001-A
Deactivation of the Window Heat Computer (WHC)


FIN: 2DG1
FIN: 2DG2
1. Reason for the Job
MMEL 30-42-01A
WINDOW HEAT COMPUTER
To do the deactivation of one of the two WHCs and to do a check of the correct operation and monitoring of the WHC that stays in operation.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 30-42-00-710-001-A
Operational Test of the Windshield Anti-Icing and Defogging
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
3. Job Set-up
Subtask 30-42-00-861-052-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 30-42-00-869-059-A
B. Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
4. Procedure
Subtask 30-42-00-710-056-A
A. Check of the Heaters of the Fixed and Sliding Windows related to the WHC in Operation
   (1) Do an operational test of the available windshield anti-icing and defogging system (Ref. AMM TASK 30-42-00-710-001).
Subtask 30-42-00-865-056-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 2DG1 (WHC1)
122VUANTI ICE/WINDOWS/L4DG1X14
122VUANTI ICE/WHC/15DG1X13
123VUANTI ICE/L/WHSLD1DG1AF10
FOR FIN: 2DG2 (WHC2)
122VUANTI ICE/WINDOWS/R4DG2W14
122VUANTI ICE/WHC/25DG2W13
123VUANTI ICE/R/WHSLD1DG2AF03
Subtask 30-42-00-210-050-A
C. Check of the Warning Messages of the Fixed and Sliding Windows related to the WHC in Operation
   (1) On the Upper ECAM DU make sure that these warning messages:
  • A.ICE L WSHLD HEAT
  • A.ICE R WSHLD HEAT
  • A.ICE L WINDOW HEAT
  • A.ICE R WINDOW HEAT
come into view.
Subtask 30-42-00-860-058-A
D. Circuit Breaker Configuration
   (1) The circuit breakers of the WHC that does not operate, must stay open, safetied and tagged.
   (2) Remove the safety clip(s) and tag(s) and close this(these) circuit breaker(s) that follow of the WHC that stays in operation:
Subtask 30-42-00-865-057-A
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 2DG1 (WHC1)
122VUANTI ICE/WINDOWS/L4DG1X14
122VUANTI ICE/WHC/15DG1X13
123VUANTI ICE/L/WHSLD1DG1AF10
FOR FIN: 2DG2 (WHC2)
122VUANTI ICE/WINDOWS/R4DG2W14
122VUANTI ICE/WHC/25DG2W13
123VUANTI ICE/R/WHSLD1DG2AF03
5. Close-up
Subtask 30-42-00-869-060-A
A. Make an entry in the log book.
Subtask 30-42-00-869-061-A
B. Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
Subtask 30-42-00-862-052-A
C. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).