W DOC AIRBUS | AMM A320F

Check of the Reservoir Quantity Indication on the ECAM Display Unit


TASK 29-30-00-200-002-A
Check of the Reservoir Quantity Indication on the ECAM Display Unit


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 29-10-00-200-001-A
Check Fluid Level on Reservoir Indicators
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
3. Job Set-up
Subtask 29-30-00-860-056-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
   (2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
   (3) Press the HYD pushbutton on the ECAM control panel to select the HYD page.
4. Procedure
Subtask 29-30-00-210-051-A
A. Check of the Reservoir Quantity Indication
   (1) Make sure that the lower display unit of the ECAM shows a reservoir quantity indication for each hydraulic system.
   (2) Make sure that the reservoir quantity indications are in the given limit of the NORMAL FILL LEVEL on the lower display unit of the ECAM.
     (a) If the reservoir quantity indication is not in the given limit of the NORMAL FILL LEVEL in the lower display unit of the ECAM, do a Check Fluid Level in Reservoir Indicator (Ref. AMM TASK 29-10-00-200-001).
5. Close-up
Subtask 29-30-00-860-057-A
A. Put the aircraft back to the serviceable condition.
   (1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
   (2) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 00:27:21 UTC