Installation of the Fire Extinguisher Bottle


TASK 26-22-41-400-001-A
Installation of the Fire Extinguisher Bottle


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: THE CARTRIDGE IS AN EXPLOSIVE DEVICE. REMOVE IT BEFORE YOU DISASSEMBLE THE FIRE EXTINGUISHER BOTTLE. TO PREVENT INJURY TO THE PERSONNEL BECAUSE OF THE EXPLOSION OF THE CARTRIDGE IF IT HAS NOT BEEN FIRED:
  • INSTALL A SHUNT DEVICE.
  • THIS WILL SHUNT THE PINS TOGETHER ON THE CARTRIDGE BEFORE ITS REMOVAL.
DO NOT USE A FOIL SHUNT.
WARNING: BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
WARNING: BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
FIN: 11WF
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
AR
ALLEN KEY 3/32 IN
No specific
AR
BOOMSET 600 OHMS
No specific
AR
HEADSET 600 OHMS
No specific
1
SCALE 36 KG (80 LB), ACCURACY 0.005 KG (0.01 LB)
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 4.0 and 3.4 m.daN (29.50 and 25.07 lbf.ft ) T
No specific
Torque wrench: range to between 7.5 and 6.1 m.daN (55.31 and 44.99 lbf.ft ) T
324467
1
CAP,PROTECTIVE-FIRE EXTINGUISHER SYSTEM
83000007
1
CRADLE-FIRE EXTINGUISHER BOTTLE
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.06LCG9)
Non Hardening Jointing Putty-Medium Temp. Area - -
(Material No.06LDG2)
Non Hardening Jointing Putty-High Temp. Area - Structure
(Material No.08BBD1)
Non Aqueous Cleaner-- Isopropyl Alcohol -
(Material No.14QFB1)
Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
314AR
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
8
O-RING
AIPC 26-22-04-01-016
16
O-RINGS
AIPC 26-22-04-02-050
19
O-RINGS
AIPC 26-22-04-02-050
8
O-RING
AIPC 26-22-84-01-030
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 20-28-00-912-802-A
Electrical Bonding - General Maintenance Procedure
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 26-22-42-400-001-A
Installation of the Fire-Extinguisher Bottle Cartridge
TASK 52-41-23-010-801-A
Opening of Access Door 314AR
TASK 52-41-23-410-801-A
Closing of Access Door 314AR
3. Job Set-up
Subtask 26-22-41-860-050-A
A. Aircraft Maintenance Configuration
   (1) Make sure that the WARNING NOTICE(S) are in position on overhead panel 25VU to tell the persons not to operate the APU.
   (2) Make sure that the WARNING NOTICE(S) are in position in the cockpit to tell the persons not to operate the pitch controls.
WARNING: BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
   (3) Put on and attach a safety harness before you start work in the work area
   (4) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below maintenance door 314AR.
   (5) Make sure that access door 314AR is open and safetied in the open position.
(Ref. AMM TASK 52-41-23-010-801).
   (6) Make sure that the light switch is set to on.
Subtask 26-22-41-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAPU/FIRE AND OVHT/DET/LOOP B2WGL44
121VUAPU/FIRE AND OVHT/DET/LOOP A1WGL43
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
121VUAPU/FIRE/EXTIG/SQUIB/B2WFL39
121VUAPU/FIRE/EXTIG/SQUIB/A1WFL38
121VUAPU/FIRE/LP VALVE/NORM4WFM42
121VUAPU/FIRE/LP VALVE/STBY3WFM41
4. Procedure
Subtask 26-22-41-280-055-A
A. Weight Check for the Meggitt Assembly
   (1) Put the 83000007 CRADLE-FIRE EXTINGUISHER BOTTLE on the SCALE 36 KG (80 LB), ACCURACY 0.005 KG (0.01 LB).
   (2) Adjust the SCALE 36 KG (80 LB), ACCURACY 0.005 KG (0.01 LB) to zero.
   (3) Put the fire extinguisher bottle in the 83000007 CRADLE-FIRE EXTINGUISHER BOTTLE.
   (4) Weigh the fire extinguisher bottle. Record the weight to the nearest 0.01 lb (0.0045 kg).
NOTE: The maximum weight without the cartridge, the discharge outlet and protective caps is 10.15 lb (4.6040 kg).
   (5) Compare the weight of the fire extinguisher to the last weight given on the identification plate.
   (6) If the fire extinguisher bottle is more than 0.10 lb (0.0454 kg) and less than the last recorded weight, do a leak test for the fire extinguisher.
Send the fire extinguisher bottle to the workshop for the leak test. Obey the manufacturer's instructions given in the related Component Maintenance Manual (CMM).
NOTE: To find the CMM reference, you can use the applicable P/N in the IPC. You can use the FIN in the task title to find the applicable P/N.
Subtask 26-22-41-280-059-A
B. Weight Check for the Kidde Assembly
WARNING: INSTALL A PROTECTIVE CAP IN THE SWIVEL NUT IMMEDIATELY AFTER YOU REMOVE THE DISCHARGE OUTLET. THE PROTECTIVE CAP PROTECTS THE DISC ASSEMBLY AND PREVENTS ACCIDENTAL RELEASE OF THE BOTTLE PRESSURE. RELEASE OF THE BOTTLE PRESSURE CAN CAUSE INJURY TO PERSONS OR DAMAGE TO EQUIPMENT.
   (1) Remove the 324467 CAP,PROTECTIVE-FIRE EXTINGUISHER SYSTEM from the swivel nut (11).
   (2) Remove the CAP - BLANKING from the fill-and-safety fitting of the fire extinguisher bottle (19).
   (3) Put the 324467 CAP,PROTECTIVE-FIRE EXTINGUISHER SYSTEM and CAP - BLANKING on a SCALE 36 KG (80 LB), ACCURACY 0.005 KG (0.01 LB). Record the weight.
   (4) Remove the 324467 CAP,PROTECTIVE-FIRE EXTINGUISHER SYSTEM and the CAP - BLANKING from the SCALE 36 KG (80 LB), ACCURACY 0.005 KG (0.01 LB).
   (5) Install the 324467 CAP,PROTECTIVE-FIRE EXTINGUISHER SYSTEM in the swivel nut (11).
   (6) Tighten the 324467 CAP,PROTECTIVE-FIRE EXTINGUISHER SYSTEM with your hand.
   (7) Install the CAP - BLANKING on the fill-and-safety fitting of the fire extinguisher bottle (19).
   (8) Put the fire extinguisher bottle (19) on the SCALE 36 KG (80 LB), ACCURACY 0.005 KG (0.01 LB). Record the weight.
   (9) Remove the fire extinguisher bottle (19) from the SCALE 36 KG (80 LB), ACCURACY 0.005 KG (0.01 LB).
   (10) Subtract the weight of the protective caps from the weight of the fire extinguisher bottle (19). This is the "TOTAL WT (ACTL)".
   (11) Compare "TOTAL WT (ACTL)" calculated in the last step to the "TOTAL WT (ACTL)" written on the identification plate. If the weights are the same, the container has no leaks.
   (12) If the weight difference is more than the permitted difference of 0.05 lb (0.02 kg), you must repair the fire extinguisher bottle (19).
Send the fire extinguisher bottle to the workshop for the repair. Obey the manufacturer's instructions given in the related Component Maintenance Manual (CMM).
NOTE: To find the CMM reference, you can use the applicable P/N in the IPC. You can use the FIN in the task title to find the applicable P/N.
   (13) If the weight difference is less than the permitted limit, remove the date from the "LAST WT INSP DATE" field on the identification plate with Non Aqueous Cleaner-- Isopropyl Alcohol - (Material No.08BBD1) and a Textile-Lint free Cotton - (Material No.14SBA1) .
   (14) Write the date when you weighed the container on the identification plate.
Subtask 26-22-41-220-050-A
C. Preparation for Installation for Meggitt Assembly
CAUTION: DO NOT TOUCH THE FRANGIBLE DISC INSIDE THE FIRE EXTINGUISHER BOTTLE UNLESS IT IS BROKEN (CARTRIDGE FIRED). YOU CAN CAUSE DAMAGE TO THE FRANGIBLE DISC OR BREAK IT.
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Make sure that the parts retained from the removed component are clean and in the correct condition.
   (4) Remove the PLUG-BLANKING from each disconnected line end.
   (5) Install a new AIPC 26-22-04-01-016 O-RING (8) or AIPC 26-22-84-01-030 O-RING (8) on the discharge outlet (10).
   (6) Make sure that the spray tubings (12), the bushing (20) and the nuts (18) are clean and in the correct condition.
   (7) Install the new
AIPC 26-22-04-02-050 O-RINGS (19) on the spray tubing (12).
Subtask 26-22-41-220-052-A Subtask 26-22-41-420-054-A ** ON A/C NOT FOR ALL
E. Installation of the Fire-Extinguisher Bottle (11WF) for Meggitt Assembly
   (1) Installation of the fire-extinguisher bottle (17):
     (a) Apply Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.
06LCG9) or Non Hardening Jointing Putty-High Temp. Area - Structure (Material No.06LDG2) to two of the bottle flanges but not to the one with the bonding strap (5).
     (b) Put the fire extinguisher bottle (17) in position.
     (c) Install the bolts (1), the washers (2) and the nuts (7). Do not tighten the nut (7) fully at this time.
     (d) Install the bonding strap (5) with the washers (4), the bolt (3) and the nut (6) (Ref. AMM TASK 20-28-00-912-802). Do not tighten the nuts (6) fully at this time.
     (e) Remove the PLUG-BLANKING from each disconnected line end.
     (f) Connect the overboard discharge pipe (14) to the fire extinguisher bottle (17). Do not tighten the nut (15) fully at this time.
   (2) Installation of the spray tubing (12):
     (a) Remove the PLUG-BLANKING from each disconnected line end.
     (b) Make sure that the O-ring (8) is correctly installed in the groove of the discharge outlet (10).
     (c) Loosely install the bushing (20).
     (d) Install the spray tubing (12) to the discharge outlet (10) and the lower spray tubing. Do not tighten the nuts (18) fully at this time.
     (e) Install the clamp (13).
     (f) Make sure that the spray tubing (12) is aligned with the discharge outlet (10).
   (3) Tighten the nuts (7) and (6) at the bottle flanges.
   (4) Tighten the nut (15) of the overboard discharge pipe (14).
   (5) Tighten the nuts (18).
   (6) Installation of the lockwire:
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (a) Safety the nuts (18) with 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
   (7) Remove the protective cap from the fire-extinguisher bottle (17).
   (8) TORQUE the swivel nut (9) to between 7.5 and 6.1 m.daN (55.31 and 44.99 lbf.ft ) T.
   (9) Installation of the lockwire:
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (a) Safety the swivel nut (9) and discharge outlet (10) with 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
   (10) Connection of the electrical connector (16):
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (a) Remove the CAP-BLANKING from each electrical connector and receptacle.
     (b) Make sure that all the electrical connections are clean and in the correct condition.
     (c) Connect the electrical connector (16).
   (11) Install the fire-extinguisher-bottle cartridge (11) (
Ref. AMM TASK 26-22-42-400-001).
Subtask 26-22-41-420-057-A ** ON A/C NOT FOR ALL
F. Installation of the Fire Extinguisher Bottle (11WF) for Kidde Assembly
   (1) Installation of the fire extinguisher bottle (19):
     (a) Apply Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) or Non Hardening Jointing Putty-High Temp. Area - Structure (Material No.06LDG2) to two of the bottle flanges but not the one with the bonding strap (8).
     (b) Put the fire extinguisher bottle (19) in position.
     (c) Install the bolts (6), the washers (5) and the nuts (4). Do not fully tighten the nuts (4) at this time.
     (d) Install the bonding strap (8) with the washers (9), the bolt (7) and the nut (10) (Ref. AMM TASK 20-28-00-912-802). Do not fully tighten the nut (10) at this time.
     (e) Remove the PLUG-BLANKING from each disconnected line end.
     (f) Remove the CAP - BLANKING from the fill-and-safety fitting of the fire extinguisher bottle (19).
     (g) Connect the overboard pipe (1) to the fill-and-safety fitting of the fire extinguisher bottle (19). Do not fully tighten the nut (2) at this time.
   (2) Installation of the spray tubing (13):
     (a) Remove the blanking plugs from the disconnected line ends.
     (b) Make sure that the 0-ring (16) is correctly installed in the groove of the discharge outlet (12).
     (c) Install the spray tubing (13) in the discharge outlet (12) and the lower spray tubing. Do not fully tighten the nuts (17) at this time.
     (d) Install the clamp (14).
     (e) Make sure that the spray tubing (13) is aligned with the discharge outlet (12).
   (3) Tighten the nuts (4) and (10) at the bottle mounting lugs.
   (4) Tighten the nut (2) of the overboard discharge pipe (1).
   (5) Tighten the nuts (17).
   (6) Installation of the lockwire:
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (a) Safety the nuts (17) with 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
   (7) Remove the protective cap from the swivel nut (11).
   (8) TORQUE the swivel nut (11) to between 4.0 and 3.4 m.daN (29.50 and 25.07 lbf.ft ) T.
   (9) Installation of the lockwire:
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (a) Safety the swivel nut (11) and discharge outlet (12) with 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
   (10) Connection of the electrical connector:
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (a) Remove the CAP-BLANKING from each electrical connector and receptacle.
     (b) Make sure that all the electrical connections are clean and in the correct condition.
     (c) Put the switch guard (3A) over the electrical connector (3).
     (d) Connect the electrical connector (3).
     (e) Put the switch guard (3A) in position and install the screw (3B).
   (11) Install the fire-extinguisher-bottle cartridge (18) (
Ref. AMM TASK 26-22-42-400-001).
Subtask 26-22-41-420-054-E ** ON A/C NOT FOR ALL
G. Installation of the Fire-Extinguisher Bottle (11WF) for Meggitt Assembly
   (1) Installation of the fire-extinguisher bottle (17):
     (a) Apply Non Hardening Jointing Putty-High Temp. Area - Structure (Material No.06LDG2) to two of the bottle flanges but not to the one with the bonding strap (5).
     (b) Put the fire extinguisher bottle (17) in position.
     (c) Install the bolts (1), the washers (2) and the nuts (7). Do not tighten the nuts (7) fully at this time.
     (d) Install the bonding strap (5) with the washers (4), the bolt (3) and the nut (6) (Ref. AMM TASK 20-28-00-912-802). Do not tighten the nuts (6) fully at this time.
     (e) Remove the PLUG-BLANKING from each disconnected line end.
     (f) Connect the overboard discharge pipe (14) to the fire extinguisher bottle (17). Do not tighten the nut (15) fully at this time.
   (2) Installation of the spray tubing (12):
     (a) Remove the PLUG-BLANKING from each disconnected line end.
     (b) Make sure that the O-ring (8) is correctly installed in the groove of the discharge outlet (10).
     (c) Loosely install the bushing (20).
     (d) Install the spray tubing (12) to the discharge outlet (10) and the lower spray tubing. Do not tighten the nuts (18) fully at this time.
     (e) Install the clamp (13).
     (f) Make sure that the spray tubing (12) is aligned with the discharge outlet (10).
   (3) Tighten the nuts (7) and (6) at the bottle flanges.
   (4) Tighten the nut (15) of the overboard discharge pipe (14).
   (5) Tighten the nuts (18).
   (6) Installation of the lockwire:
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (a) Safety the nuts (18) with 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
   (7) Remove the protective cap from the fire-extinguisher bottle (17).
   (8) TORQUE the swivel nut (9) to between 7.5 and 6.1 m.daN (55.31 and 44.99 lbf.ft ) T.
   (9) Installation of the lockwire:
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (a) Safety the swivel nut (9) and discharge outlet (10) with 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
   (10) Connection of the electrical connector (16):
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (a) Remove the CAP-BLANKING from each electrical connector and receptacle.
     (b) Make sure that all the electrical connections are clean and in the correct condition.
     (c) Connect the electrical connector (16).
   (11) Install the fire-extinguisher-bottle cartridge (11) (
Ref. AMM TASK 26-22-42-400-001).
Subtask 26-22-41-420-057-B ** ON A/C NOT FOR ALL
H. Installation of the Fire Extinguisher Bottle (11WF) for Kidde Assembly
   (1) Installation of the fire extinguisher bottle (19):
     (a) Apply Non Hardening Jointing Putty-High Temp. Area - Structure (Material No.06LDG2) to two of the bottle flanges but not the one with the bonding strap (8).
     (b) Put the fire extinguisher bottle (19) in position.
     (c) Install the bolts (6), the washers (5) and the nuts (4). Do not fully tighten the nuts (4) at this time.
     (d) Install the bonding strap (8) with the washers (9), the bolt (7) and the nut (10) (Ref. AMM TASK 20-28-00-912-802). Do not fully tighten the nut (10) at this time.
     (e) Remove the blanking plugs from the disconnected line ends.
     (f) Connect the overboard pipe (1). Do not fully tighten the nut (2) at this time.
   (2) Installation of the spray tubing (13):
     (a) Remove the blanking plugs from the disconnected line ends.
     (b) Make sure that the 0-ring (16) is correctly installed in the groove of the discharge outlet (12).
     (c) Install the spray tubing (13) in the discharge outlet (12) and the lower spray tubing. Do not fully tighten the nuts (17) at this time.
     (d) Install the clamp (14).
     (e) Make sure that the spray tubing (13) is aligned with the discharge outlet (12).
   (3) Tighten the nuts (4) and (10) at the bottle mounting lugs.
   (4) Tighten the nut (2) of the overboard discharge pipe (1).
   (5) Tighten the nuts (17).
   (6) Installation of the lockwire:
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (a) Safety the nuts (17) with 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
   (7) Remove the protective cap from the swivel nut (11).
   (8) TORQUE the swivel nut (11) to between 4.0 and 3.4 m.daN (29.50 and 25.07 lbf.ft ) T.
   (9) Installation of the lockwire:
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (a) Safety the swivel nut (11) and discharge outlet (12) with 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
   (10) Connection of the electrical connector:
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (a) Remove the blanking caps from the electrical connectors.
     (b) Make sure that all the electrical connections are clean and in the correct condition.
     (c) Put the switch guard (3A) over the electrical connector (3).
     (d) Connect the electrical connector (3).
     (e) Put the switch guard (3A) in position and install the screw (3B).
   (11) Install the fire-extinguisher-bottle cartridge (18) (
Ref. AMM TASK 26-22-42-400-001).
Subtask 26-22-41-860-051-A
I. Preparation for Test
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
NOTE: For this test procedure we recommend that a minimum of two persons are in constant contact with each other through the service interphone system. One person must monitor the cockpit APU FIRE panel 20VU, the other person must be at Zone 313.
   (2) On the CAPT jack panel, connect the HEADSET 600 OHMS to the related connector.
   (3) On the overhead panel 50VU, make sure that the ON legend on the SVCE INT OVRD pushbutton switch is off.
   (4) In Zone 314, connect the BOOMSET 600 OHMS to the service interphone jack.
Subtask 26-22-41-865-053-A
J. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAPU/FIRE AND OVHT/DET/LOOP B2WGL44
121VUAPU/FIRE AND OVHT/DET/LOOP A1WGL43
121VUAPU/FIRE/EXTIG/SQUIB/B2WFL39
121VUAPU/FIRE/EXTIG/SQUIB/A1WFL38
121VUAPU/FIRE/LP VALVE/NORM4WFM42
121VUAPU/FIRE/LP VALVE/STBY3WFM41
Subtask 26-22-41-710-051-A
K. Do the operational test of Fire Extinguisher Bottle
  • Make sure that the circuit breaker(s) APU/ECB/SPLY 1KD (L41) and APU/APU/CTL 2KD (L42) on the panel 121VU are open.
ACTION
RESULT
1.On the APU FIRE panel 20VU:
  • press and hold the TEST pushbutton switch.
On the APU FIRE panel 20VU:
  • the SQUIB and the DISCH legends in the AGENT pushbutton switch come on.
2.On the APU FIRE panel 20VU:
  • release the TEST pushbutton switch.
On the APU FIRE panel 20VU:
  • the SQUIB and the DISCH legends in the AGENT pushbutton switch go off.
3.On the pressure switch of the fire extinguisher bottle:
  • put the ALLEN KEY 3/32 IN into the pressure switch hexagon test-socket. Slowly turn the allen key clockwise or counterclockwise approx. 10 degrees.
On the APU FIRE panel 20VU:

  • the DISCH legend in the AGENT pushbutton switch comes on.
4.On the pressure switch of the fire extinguisher bottle:
  • slowly turn the allen key to the initial position and remove it.
On the APU FIRE panel 20VU:

  • the DISCH legend in the AGENT pushbutton switch goes off.
5. Close-up
Subtask 26-22-41-865-055-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
Subtask 26-22-41-860-052-A
B. Put the aircraft back to its initial configuration.
   (1) On the CAPT jack panel, disconnect the HEADSET 600 OHMS from the related connector.
   (2) In Zone 314, disconnect the BOOMSET 600 OHMS to the service interphone jack.
   (3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Subtask 26-22-41-410-052-A
C. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Set the light switch to off.
   (3) Close access door 314AR (Ref. AMM TASK 52-41-23-410-801).
   (4) Remove the WARNING NOTICE(S).
   (5) Remove the access platform(s).
[Rev.10 from 2021] 2026.03.31 23:45:38 UTC