Closing of Access Door 314AR
TASK 52-41-23-410-801-A
Closing of Access Door 314AR
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 52-41-23-860-053-A
Subtask 52-41-23-410-051-A
Subtask 52-41-23-942-050-A
[Rev.10 from 2021]
2026.04.01 03:49:54 UTC
Closing of Access Door 314AR
WARNING:
DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
ZONE: 310
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| No specific | Torque wrench: range to between 3 and 2.7 m.N (26.55 and 23.89 lbf.in ) ![]() |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 310 | FUSLG TAIL SECTION AFT OF AFT PRESS BHD |
| 314AR |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 52-41-23-860-053-A
A. Aircraft Maintenance Configuration
(1) Make sure that the WARNING NOTICE(S) is(are) in position in the flight compartment to tell persons not to start the APU.
(2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below access door 314AR.
4. Procedure(1) Make sure that the WARNING NOTICE(S) is(are) in position in the flight compartment to tell persons not to start the APU.
(2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below access door 314AR.
Subtask 52-41-23-410-051-A
A. Closing of Access Door 314AR
(1) Remove the quick-release pin (3) from the rod (4) and the bracket (2).
(2) Release the rod (4) from the bracket (2).
(3) Install the rod (4) in the clamp (5).
(4) Close access door 314AR (1) and tighten the studs (6).
(5) TORQUE the studs (6) to between 3 and 2.7 m.N (26.55 and 23.89 lbf.in )
.
5. Close-up(1) Remove the quick-release pin (3) from the rod (4) and the bracket (2).
(2) Release the rod (4) from the bracket (2).
(3) Install the rod (4) in the clamp (5).
(4) Close access door 314AR (1) and tighten the studs (6).
(5) TORQUE the studs (6) to between 3 and 2.7 m.N (26.55 and 23.89 lbf.in )
.Subtask 52-41-23-942-050-A
A. Aircraft Maintenance Configuration
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the WARNING NOTICE(S).
(3) Remove the access platform(s).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the WARNING NOTICE(S).
(3) Remove the access platform(s).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Access Door 314AR