W DOC AIRBUS | AMM A320F

Cleaning of the Essential Transformer Rectifier (TR)


TASK 24-34-00-100-801-A
Cleaning of the Essential Transformer Rectifier (TR)


ZONE: 126
FIN: 1PE
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
1
AIR SOURCE FILTERED, DRY
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
VACUUM CLEANER
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BBD1)
Non Aqueous Cleaner-- Isopropyl Alcohol -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
126
LATERAL AVIONIC COMPARTMENT
812
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-24-00-710-001-A
Operational Check of Emergency Generating System
TASK 24-34-51-000-001-A
Removal of the Essential Transformer Rectifier
TASK 24-34-51-400-001-A
Installation of the Essential Transformer Rectifier
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
3. Job Set-up
Subtask 24-34-00-861-051-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 24-34-00-010-052-A
B. Get access to the avionics compartment.
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below access door 812.
   (2) Open access door 812 (Ref. AMM TASK 52-41-00-010-002).
   (3) In the avionics compartment, open the access panel of AC/DC emergency power-center 106VU.
Subtask 24-34-00-865-055-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
106VUESS TR/SPLY4PEC01
4. Procedure
Subtask 24-34-00-210-051-A
A.
WARNING: WHEN YOU USE COMPRESSED AIR:
  • USE THE CORRECT PROTECTION (FACE SHIELD OR GOGGLES)
  • DO NOT POINT THE AIRFLOW AT YOURSELF OR OTHER PERSONS.
LOOSE PARTICLES AND/OR HIGH PRESSURE AIR CAN CAUSE INJURY.
CAUTION: IF THERE IS DRY SAND/DUST, DO NOT USE FLUIDS TO REMOVE THE SAND/DUST. IF THERE IS LAYER OF SAND/DUST ON THE AIRCRAFT SURFACES, REMOVE THE SAND/DUST WITH A VACUUM CLEANER (OR, IF YOU CANNOT USE A VACUUM CLEANER, USE AN AIR BLOWER, A SOFT CLOTH OR A HAND BRUSH). FLUIDS CAN MIX WITH THE SAND/DUST AND MAKE A PASTE THAT CAN CAUSE EROSION/ABRASION. THIS PASTE CAN GO INTO AREAS THAT ARE NOT EASY TO CLEAN.
CAUTION: MAKE SURE THAT THE VACUUM CLEANER IS CLEAN. IF YOU USE A VACUUM CLEANER THAT IS NOT CLEAN, THERE IS A RISK OF DUST CONTAMINATION IN THE AVIONICS COMPARTMENT.
   (1) Remove the essential TR (1) (Ref. AMM TASK 24-34-51-000-001).
   (2) Remove the dust from the essential TR (1) and the adjacent area with the VACUUM CLEANER.
   (3) Remove the dust collected in the essential TR (1) with the low pressure AIR SOURCE FILTERED, DRY.
   (4) If necessary, clean the external surfaces of the essential TR (1) with the Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-- Isopropyl Alcohol - (Material No.08BBD1) .
   (5) Clean the ventilation grid of the essential TR (1) with the VACUUM CLEANER.
   (6) Install the essential TR (1) (Ref. AMM TASK 24-34-51-400-001).
Subtask 24-34-00-865-056-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
106VUESS TR/SPLY4PEC01
Subtask 24-34-00-710-051-A
C. Operational Test of the Emergency Generation System
   (1) Do the operational test of the emergency generation system (Ref. AMM TASK 24-24-00-710-001).
5. Close-up
Subtask 24-34-00-410-052-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) In the avionics compartment, close the access panel of AC/DC emergency power-center 106VU.
   (3) Close access door 812 (Ref. AMM TASK 52-41-00-410-002).
   (4) Remove the access platform(s).
Subtask 24-34-00-862-051-A
B. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.03.31 23:23:30 UTC