W DOC AIRBUS | AMM A320F

Uploading of the Flight Management (FM) Data to the Flight Management and Guidance Computer (FMGC)


TASK 22-70-00-610-008-C-01
Uploading of the Flight Management (FM) Data to the Flight Management and Guidance Computer (FMGC)


WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
ZONE: 210
FIN: 1CA1 ** ON A/C NOT FOR ALL
FIN: 1CA2 ** ON A/C NOT FOR ALL
1. Reason for the Job
To upload the FM data with the Portable Data Loader (PDL) in these conditions:
  • If the Multipurpose Disk Drive Unit (MDDU) is defective and there is no spare available to replace it.
  • If you must update the navigation database (MMEL 22-70-02A) to make the aircraft dispatch possible.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
31530-2
1
PDL CABLE ADAPTR-MDDU
602751-003
1
PDL CABLE ADAPTR-MDDU
ALT45200001
1
PORTABLE DATA LOADER
YV68A110
1
PORTABLE DATA LOADER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 22-70-00-610-008-C
Uploading of the Flight Management (FM) Data to the Flight Management and Guidance Computer (FMGC)
TASK 22-70-00-610-008-C-01
Uploading of the Flight Management (FM) Data to the Flight Management and Guidance Computer (FMGC)
TASK 22-70-00-610-009-A
Crossloading of the Flight Management (FM) Data
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-38-22-000-001-A
Removal of the MDDU
TASK 31-38-22-400-001-A
Installation of the MDDU
3. Job Set-up
Subtask 22-70-00-941-051-A ** ON A/C NOT FOR ALL
A. If the MDDU is serviceable, upload the FM data with the MDDU (Ref. AMM TASK 22-70-00-610-008).
Subtask 22-70-00-861-075-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Make sure that the aircraft is in the ground configuration.
Subtask 22-70-00-865-128-A ** ON A/C NOT FOR ALL
C. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAUTO FLT/FMGC/110CA1B02
49VUAUTO FLT/MCDU/111CA1B01
121VUAUTO FLT/FMGC/210CA2M17
121VUAUTO FLT/MCDU/211CA2N20
121VUHYDRAULIC/LGCIU/SYS22GAQ35
Subtask 22-70-00-610-082-A ** ON A/C NOT FOR ALL
D. Prepare the media disk(s).
   (1) Get the media disk(s) from the storage box in the cockpit.
NOTE: It is not mandatory to keep the database media disk(s) in the storage box in the cockpit. Thus, you can keep the database media disk(s) in the storage area.
   (2) Make sure that the Part Number(s) (P/N) written on the media disk(s) is(are) the same as the P/N(s) written in the airline configuration management-document.
     (a) If the media disk(s) is(are) not available or not the correct one(s), contact your airline engineering department to get the correct part number(s) applicable to the aircraft.
Subtask 22-70-00-280-074-C ** ON A/C NOT FOR ALL
E. Check of the P/N(s) of the Software Component(s) (Pre-loaded to the Related FMGC)

NOTE: If the software component(s) that you upload is(are) not correct, the FMGC will not accept the uploading.
NOTE: If you upload the FMS operational-program software-component, it is necessary to upload these software components again:
  • The navigation database
  • The airline modifiable-information file
  • The operational program-configuration file
  • The performance database
  • The magnetic variation database.
    On the Multipurpose Control & Display Unit (MCDU), if you push the MCDU FM mode key, the "NOT ALLOWED" message will come into view on the scratchpad.
  • Until you upload the software components again
  • If the FM software component is not compatible with the Flight Guidance (FG) software component.
   (1) Do a check of the P/N(s) of the software component(s):

ACTION
RESULT
1.On MCDU1(2):
  • Adjust the brightness of the MCDU screen.
  • Push the DATA mode key.

2.On MCDU1(2):
  • Push the line select key adjacent to the "A/C STATUS" indication.
On MCDU1(2):
  • The "A/C STATUS" page comes into view.
3.On the "A/C STATUS" page:
  • Record the "IDLE/PERF" value (shown adjacent to line select key 6L).

4.On the "A/C STATUS" page:
  • Push the line select key adjacent to the "SOFTWARE STATUS/XLOAD" indication.
On MCDU1(2):
  • The "P/N STATUS" page comes into view.
5.Make sure that the software components that follow are in the FMGC:
  • The FM operational software-component with the FMS operational program-disk (1CAMD3) or the FMS operational program CD-ROM (1CAMD7)
    (Page 2: FMS SOFTWARE)
  • The navigation database with the active nav database-disk (the navigation database changes at intervals of 28 days)
    (Page 3: NAV DATA BASE)
  • The airline modifiable-information file with the applicable disk
    (Page 4: FM AIRLINE CONFIG (AMI))
  • The operational program-configuration file with the FMS option configuration-disk (1CAMD1) or the FMS option-configuration CD-ROM (1CAMD5)
    (Page 5: FM OPTIONS CONFIG (OPC))
  • The performance database with the FMS performance database-disk (1CAMD2) or the FMS performance-database CD-ROM (1CAMD6)
    (Page 6: PERF DATA BASE).

6.Before you do the uploading procedure, on the "P/N STATUS" page:
  • Read the P/N of the software component that you want to upload.
  • Make sure that this P/N is not the same as the P/N written on the media disk.
NOTE: If the P/N is the same, the uploading is not necessary.

4. Procedure
Subtask 22-70-00-970-072-D ** ON A/C NOT FOR ALL
A. Uploading of the FM Data to FMGC1(2)
NOTE: This procedure is for FMGC1. For FMGC2, you can refer to the data between the parentheses.
   (1) After the uploading of the FMGC is completed, upload the other FMGC with the crossload function.
   (2) To do the crossloading procedure, ignore the crossloading prompt on the "P/N STATUS" page of MCDU1(2). Wait until the FMGC1(2) crossloading prompt comes into view on the "P/N STATUS" page of MCDU1(2).
NOTE: The FMGC1(2) crossloading prompt comes into view only if all the mandatory software components (FMS software component, navigation database, FMS options-configuration software-component, performance database and magnetic variation database) are uploaded.
   (3) For FMGC2, do the crossloading of the FM data (Ref. AMM TASK 22-70-00-610-009).
NOTE: The uploading time for one full media disk is approximately 12 minutes.
   (4) After the uploading procedure, do a check of the P/N(s) of the software component(s) uploaded to the FMGC, on the MCDU.
ACTION
RESULT
1.On the center pedestal, on MCDU1(2):
  • Adjust the brightness of the MCDU screen.

2.On the rear circuit-breaker panel:
  • Open circuit breaker 3TD.

3.On the ALT45200001 PORTABLE DATA LOADER or the YV68A110 PORTABLE DATA LOADER:
  • Set the ON/OFF control switch to OFF.
  • Connect the 31530-2 PDL CABLE ADAPTR-MDDU or the 602751-003 PDL CABLE ADAPTR-MDDU.

4.On panel 11VU:

5.On the rear circuit-breaker panel:
  • Close circuit breaker 3TD.

6.On the overhead panel, on the DLS:
  • Set the ON/OFF control switch to ON.
On the display of the DLS:
  • The "DB/N: PUSH NEXT/PREV" indication comes into view.
7.On the overhead panel and the rear circuit-breaker panel:
  • Open circuit breakers 10CA1 and 10CA2.

8.On the DLS:
  • Push the PREV or NEXT key until you get the indication of the FMGC that you want to upload.
  • Push the SEL CTL key.
On the display of the DLS:
  • The "FMGC1(2) NOT SELECTED" indication comes into view.
  • The "FMGC1(2) SELECTED" indication comes into view.
9.On the ALT45200001 PORTABLE DATA LOADER or the YV68A110 PORTABLE DATA LOADER:
  • Set the ON/OFF control switch to ON.

10.Use the applicable media disk(s) from the media disk storage-box.

11.On the ALT45200001 PORTABLE DATA LOADER or the YV68A110 PORTABLE DATA LOADER:
  • Put the media disk into the media disk drive.
On the ALT45200001 PORTABLE DATA LOADER or the YV68A110 PORTABLE DATA LOADER:
  • The "MDDU READY" or "UNIT READY" indication comes into view.
  • Then, the "WAIT RESPONSE" indication comes into view.
12.On the overhead panel and the rear circuit-breaker panel:
  • Close circuit breakers 10CA1 and 10CA2.
  • If a transfer fault occurs during the uploading and if more than one media disk is necessary, do the uploading again from media disk 1.
On the ALT45200001 PORTABLE DATA LOADER or the YV68A110 PORTABLE DATA LOADER:
  • The "MDDU READY" or "UNIT READY" indication comes into view.
  • Then, the "WAIT RESPONSE" indication comes into view and immediately the "TRANSF IN PROG" indication comes into view.
  • At the end of the uploading, the "TRANSF COMPLETE" indication comes into view.
13.On the ALT45200001 PORTABLE DATA LOADER or the YV68A110 PORTABLE DATA LOADER:
  • Eject the media disk from the media disk drive.
  • Set the ON/OFF control switch to OFF.

14.On the overhead panel, on the DLS:
  • Push the SEL CTL key.
On the display of the DLS:
  • The "FMGC1(2) NOT SELECTED" indication comes into view.
15.On the DLS:
  • Set the ON/OFF control switch to OFF.

16.On the overhead panel and the rear circuit-breaker panel:
  • Open circuit breakers 10CA1(10CA2) and 3TD.

17.On panel 11VU:

18.On the ALT45200001 PORTABLE DATA LOADER or the YV68A110 PORTABLE DATA LOADER:
  • Disconnect the 31530-2 PDL CABLE ADAPTR-MDDU or the 602751-003 PDL CABLE ADAPTR-MDDU.

19.On the overhead panel and the rear circuit-breaker panel:
  • Close circuit breakers 10CA1(10CA2) and 3TD and wait for the FMGC safety test.

20.On the center pedestal, on MCDU1(2):
  • Push the MCDU MENU mode key.
  • Push the line select key adjacent to the "FMGC" indication.
  • Push the DATA mode key.
  • Push the line select key adjacent to the "A/C STATUS" indication.
On MCDU1(2):
  • The "MCDU MENU" page comes into view.
  • The "FM" page comes into view.
  • The "DATA INDEX" page comes into view.
  • The "A/C STATUS" page comes into view.
5. Close-up
Subtask 22-70-00-860-121-B ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) On MCDU1(2), push the MCDU MENU mode key to get access to the "MCDU MENU" page.
   (2) Fully decrease the brightness of the MCDU screen (display off).
   (3) Put the media disk(s) back into the storage box in the cockpit.
NOTE: It is not mandatory to keep the database media disk(s) in the storage box in the cockpit. Thus, you can keep the database media disk(s) in the storage area.
Subtask 22-70-00-862-083-A ** ON A/C NOT FOR ALL
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).