Uploading of the Flight Management (FM) Data to the Flight Management and Guidance Computer (FMGC)
TASK 22-70-00-610-008-C-01
Uploading of the Flight Management (FM) Data to the Flight Management and Guidance Computer (FMGC)
To upload the FM data with the Portable Data Loader (PDL) in these conditions:
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 22-70-00-941-051-A ** ON A/C NOT FOR ALL Subtask 22-70-00-861-075-A ** ON A/C NOT FOR ALL
Subtask 22-70-00-970-072-D ** ON A/C NOT FOR ALL
Subtask 22-70-00-860-121-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:10:48 UTC
Uploading of the Flight Management (FM) Data to the Flight Management and Guidance Computer (FMGC)
WARNING:
MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
1. Reason for the JobTo upload the FM data with the Portable Data Loader (PDL) in these conditions:
- If the Multipurpose Disk Drive Unit (MDDU) is defective and there is no spare available to replace it.
- If you must update the navigation database (MMEL 22-70-02A) to make the aircraft dispatch possible.
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| 31530-2 | 1 | PDL CABLE ADAPTR-MDDU |
| 602751-003 | 1 | PDL CABLE ADAPTR-MDDU |
| ALT45200001 | 1 | PORTABLE DATA LOADER |
| YV68A110 | 1 | PORTABLE DATA LOADER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 22-70-00-610-008-C | Uploading of the Flight Management (FM) Data to the Flight Management and Guidance Computer (FMGC) |
| TASK 22-70-00-610-008-C-01 | Uploading of the Flight Management (FM) Data to the Flight Management and Guidance Computer (FMGC) |
| TASK 22-70-00-610-009-A | Crossloading of the Flight Management (FM) Data |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-38-22-000-001-A | Removal of the MDDU |
| TASK 31-38-22-400-001-A | Installation of the MDDU |
Subtask 22-70-00-941-051-A ** ON A/C NOT FOR ALL Subtask 22-70-00-861-075-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the aircraft is in the ground configuration.
Subtask 22-70-00-865-128-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the aircraft is in the ground configuration.
C. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 22-70-00-610-082-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AUTO FLT/FMGC/1 | 10CA1 | B02 |
| 49VU | AUTO FLT/MCDU/1 | 11CA1 | B01 |
| 121VU | AUTO FLT/FMGC/2 | 10CA2 | M17 |
| 121VU | AUTO FLT/MCDU/2 | 11CA2 | N20 |
| 121VU | HYDRAULIC/LGCIU/SYS2 | 2GA | Q35 |
D. Prepare the media disk(s).
(1) Get the media disk(s) from the storage box in the cockpit.
(a) If the media disk(s) is(are) not available or not the correct one(s), contact your airline engineering department to get the correct part number(s) applicable to the aircraft.
Subtask 22-70-00-280-074-C ** ON A/C NOT FOR ALL (1) Get the media disk(s) from the storage box in the cockpit.
NOTE: It is not mandatory to keep the database media disk(s) in the storage box in the cockpit. Thus, you can keep the database media disk(s) in the storage area.
(2) Make sure that the Part Number(s) (P/N) written on the media disk(s) is(are) the same as the P/N(s) written in the airline configuration management-document.(a) If the media disk(s) is(are) not available or not the correct one(s), contact your airline engineering department to get the correct part number(s) applicable to the aircraft.
E. Check of the P/N(s) of the Software Component(s) (Pre-loaded to the Related FMGC)
4. ProcedureNOTE: If the software component(s) that you upload is(are) not correct, the FMGC will not accept the uploading.
NOTE: If you upload the FMS operational-program software-component, it is necessary to upload these software components again:
(1) Do a check of the P/N(s) of the software component(s):- The navigation database
- The airline modifiable-information file
- The operational program-configuration file
- The performance database
- The magnetic variation database.
On the Multipurpose Control & Display Unit (MCDU), if you push the MCDU FM mode key, the "NOT ALLOWED" message will come into view on the scratchpad. - Until you upload the software components again
- If the FM software component is not compatible with the Flight Guidance (FG) software component.
| ACTION | RESULT |
|---|---|
1.On MCDU1(2):
| |
2.On MCDU1(2):
| On MCDU1(2):
|
3.On the "A/C STATUS" page:
| |
4.On the "A/C STATUS" page:
| On MCDU1(2):
|
5.Make sure that the software components that follow are in the FMGC:
| |
6.Before you do the uploading procedure, on the "P/N STATUS" page:
NOTE: If the P/N is the same, the uploading is not necessary. | |
Subtask 22-70-00-970-072-D ** ON A/C NOT FOR ALL
A. Uploading of the FM Data to FMGC1(2)
(2) To do the crossloading procedure, ignore the crossloading prompt on the "P/N STATUS" page of MCDU1(2). Wait until the FMGC1(2) crossloading prompt comes into view on the "P/N STATUS" page of MCDU1(2).
5. Close-upNOTE: This procedure is for FMGC1. For FMGC2, you can refer to the data between the parentheses.
(1) After the uploading of the FMGC is completed, upload the other FMGC with the crossload function.(2) To do the crossloading procedure, ignore the crossloading prompt on the "P/N STATUS" page of MCDU1(2). Wait until the FMGC1(2) crossloading prompt comes into view on the "P/N STATUS" page of MCDU1(2).
NOTE: The FMGC1(2) crossloading prompt comes into view only if all the mandatory software components (FMS software component, navigation database, FMS options-configuration software-component, performance database and magnetic variation database) are uploaded.
(3) For FMGC2, do the crossloading of the FM data (Ref. AMM TASK 22-70-00-610-009).NOTE: The uploading time for one full media disk is approximately 12 minutes.
(4) After the uploading procedure, do a check of the P/N(s) of the software component(s) uploaded to the FMGC, on the MCDU.| ACTION | RESULT |
|---|---|
1.On the center pedestal, on MCDU1(2):
| |
2.On the rear circuit-breaker panel:
| |
3.On the ALT45200001 PORTABLE DATA LOADER or the YV68A110 PORTABLE DATA LOADER:
| |
4.On panel 11VU:
| |
5.On the rear circuit-breaker panel:
| |
6.On the overhead panel, on the DLS:
| On the display of the DLS:
|
7.On the overhead panel and the rear circuit-breaker panel:
| |
8.On the DLS:
| On the display of the DLS:
|
9.On the ALT45200001 PORTABLE DATA LOADER or the YV68A110 PORTABLE DATA LOADER:
| |
| 10.Use the applicable media disk(s) from the media disk storage-box. | |
11.On the ALT45200001 PORTABLE DATA LOADER or the YV68A110 PORTABLE DATA LOADER:
| On the ALT45200001 PORTABLE DATA LOADER or the YV68A110 PORTABLE DATA LOADER:
|
12.On the overhead panel and the rear circuit-breaker panel:
| On the ALT45200001 PORTABLE DATA LOADER or the YV68A110 PORTABLE DATA LOADER:
|
13.On the ALT45200001 PORTABLE DATA LOADER or the YV68A110 PORTABLE DATA LOADER:
| |
14.On the overhead panel, on the DLS:
| On the display of the DLS:
|
15.On the DLS:
| |
16.On the overhead panel and the rear circuit-breaker panel:
| |
17.On panel 11VU:
| |
18.On the ALT45200001 PORTABLE DATA LOADER or the YV68A110 PORTABLE DATA LOADER:
| |
19.On the overhead panel and the rear circuit-breaker panel:
| |
20.On the center pedestal, on MCDU1(2):
| On MCDU1(2):
|
Subtask 22-70-00-860-121-B ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) On MCDU1(2), push the MCDU MENU mode key to get access to the "MCDU MENU" page.
(2) Fully decrease the brightness of the MCDU screen (display off).
(3) Put the media disk(s) back into the storage box in the cockpit.
Subtask 22-70-00-862-083-A ** ON A/C NOT FOR ALL (1) On MCDU1(2), push the MCDU MENU mode key to get access to the "MCDU MENU" page.
(2) Fully decrease the brightness of the MCDU screen (display off).
(3) Put the media disk(s) back into the storage box in the cockpit.
NOTE: It is not mandatory to keep the database media disk(s) in the storage box in the cockpit. Thus, you can keep the database media disk(s) in the storage area.