W DOC AIRBUS | AMM A320F

Installation of the MDDU


TASK 31-38-22-400-001-A
Installation of the MDDU


ZONE: 210
FIN: 1TD ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-38-00-740-002-A
BITE Test of the Multipurpose Disk Drive Unit (MDDU)
3. Job Set-up
Subtask 31-38-22-860-050-A ** ON A/C NOT FOR ALL
A. Make sure that the aircraft electrical circuits from the external power is de-energized (Ref. AMM TASK 24-41-00-862-002).
Subtask 31-38-22-875-051-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUDATA/LOADER/SPLY3TDJ16
121VUDLS&/DLRB/SPLY5TDJ15
4. Procedure
Subtask 31-38-22-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the MDDU
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (4) Make sure that all the electrical connections are clean and in the correct condition.
   (5) Connect the electrical connector (2).
   (6) Make sure that the work area is clean and clear of tool(s) and other items in the MDDU housing.
   (7) Install the MDDU (1) in its housing.
   (8) Tighten the four quarter-turn fasteners (3).
Subtask 31-38-22-861-051-A ** ON A/C NOT FOR ALL
B. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 31-38-22-875-052-A ** ON A/C NOT FOR ALL
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUDATA/LOADER/SPLY3TDJ16
121VUDLS&/DLRB/SPLY5TDJ15
Subtask 31-38-22-710-050-A ** ON A/C NOT FOR ALL
D. On the MDDU, make sure that the < < MDDU READY > > indication is shown.
Subtask 31-38-22-740-050-A ** ON A/C NOT FOR ALL
E. Do the BITE test of the MDDU (Ref. AMM TASK 31-38-00-740-002).
5. Close-up
Subtask 31-38-22-862-051-A ** ON A/C NOT FOR ALL
A. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).