Operational Test of the FWD Cargo Compartment Heating System
TASK 21-43-00-710-002-A
Operational Test of the FWD Cargo Compartment Heating System
Self explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 21-43-00-861-062-A ** ON A/C NOT FOR ALL Subtask 21-43-00-865-063-A ** ON A/C NOT FOR ALL
Subtask 21-43-00-710-055-A ** ON A/C NOT FOR ALL
Subtask 21-43-00-860-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 05:01:58 UTC
Operational Test of the FWD Cargo Compartment Heating System
NOTE: The controlled temperature range for which the system has been designed is between 5 deg.C (41 deg.F) and 26 deg.C (78.8 deg.F). For that reason, before proceeding with the operational test and in the case of high outside air temperature, it is recommended to cool the FWD cargo compartment below 26 deg.C (78.8 deg.F).
NOTE: If the APU is not available, connect a ground source supply to the aircraft high pressure connector. The flow rate should not exceed 1.0 Kg/s at a temperature of 200 deg.C.
NOTE: Make sure that you close and lock the FWD cargo-compartment door.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-33-21-618-001-A-02 | Pre-conditioning with the APU |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 26-16-00-710-003-A | Operational Check of Cargo Compartment Smoke Detection by CFDS to Confirm Isolation Valves Latching Circuit Integrity. |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
Subtask 21-43-00-861-062-A ** ON A/C NOT FOR ALL Subtask 21-43-00-865-063-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 21-43-00-860-050-B ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/FWD CARGO/VENT/CTL & MONG | 2HN | C08 |
| 49VU | AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC | 52HH | D08 |
| 122VU | FWD CARGO VENT AND HTG/FAN | 1HN | T22 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/115VAC | 53HH | W22 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/28VDC | 55HH | W21 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/115VAC | 49HH | X22 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/28VDC | 51HH | X21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/28VDC | 56HH | Y21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/115VAC | 54HH | Y20 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN B/115VAC | 50HH | Y18 |
C. Aircraft Maintenance Configuration
(1) On the AIR COND panel 30VU:
(4) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(5) Do the preconditioning with the APU (Ref. AMM TASK 12-33-21-618-001).
4. Procedure(1) On the AIR COND panel 30VU:
- make sure that the PACK 1 and the PACK 2 pushbutton switches are in the on position (with the FAULT and OFF legend off).
- make sure that the X-BLEED selector is in the AUTO position.
- make sure that the ECON FLOW pushbutton switch is in the off position (with the ON legend off).
- make sure that the HOT AIR pushbutton switch is in the on position (with the FAULT and OFF legend off).
- make sure that the FWD cargo TEMP selector is in the 12 o'clock position.
- make sure that the FWD ISOL VALVE pushbutton switch is in the on position (with the FAULT and OFF legend off).
(4) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(5) Do the preconditioning with the APU (Ref. AMM TASK 12-33-21-618-001).
Subtask 21-43-00-710-055-A ** ON A/C NOT FOR ALL
A. Operational Tests
(1) Do the operational test of the Fwd cargo-compartment heating system:
(2) Do the operational test of the FWD cargo-compartment smoke-detection with the CFDS to confirm isolation valve latching circuit integrity. (Ref. AMM TASK 26-16-00-710-003).
5. Close-up(1) Do the operational test of the Fwd cargo-compartment heating system:
| ACTION | RESULT |
|---|---|
1.On the panel 30VU:
| On the panel 30VU:
|
2.On the ECAM control panel 11VU:
| On the ECAM lower display unit:
|
3.On the panel 22VU:
|
|
|
|
Subtask 21-43-00-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Stop the preconditioning with the APU (Ref. AMM TASK 12-33-21-618-001).
(2) On the AIR COND panel 30VU:
(Ref. AMM TASK 31-60-00-860-002).
Subtask 21-43-00-862-058-A ** ON A/C NOT FOR ALL (1) Stop the preconditioning with the APU (Ref. AMM TASK 12-33-21-618-001).
(2) On the AIR COND panel 30VU:
- make sure that the PACK 1 and the PACK 2 pushbutton switches are in the OFF position.
- make sure that the APU BLEED pushbutton switch is in the off position (with the FAULT and ON legend off).
- make sure that the FWD ISOL VALVE pushbutton switch is in the OFF position.
- make sure that the FWD cargo TEMP selector in the 12 o'clock position.
(Ref. AMM TASK 31-60-00-860-002).