24-41 AC EXTERNAL POWER CONTROL
- PB.201 AC EXTERNAL POWER CONTROL - FAULT ISOLATION PROCEDURES
-
24-41-00-810-801-A
[8]
Failure of the Ground Power Control Unit -
24-41-00-810-802-A
[8]
Failure of the Connection between the GPCU and the APU GCU -
24-41-00-810-803-A
[8]
Failure of the RS422 Electrical Connection between the GPCU and the APU GCU -
24-41-00-810-804-A
[8]
Failure of the RS422 Electrical Connection between the GPCU and the GCU 1 -
24-41-00-810-805-A
[8]
Failure of the RS422 Electrical Connection between the GPCU and the GCU 2 -
24-41-00-810-806-A
[8]
Failure of the RS422 Electrical Connection between the GPCU and the GCU 1 -
24-41-00-810-807-A
[8]
Failure of the RS422 Electrical Connection between the GPCU and the GCU 2 -
24-41-00-810-808-A
[8]
Loss of the CFDIU Discrete Signal to the GPCU -
24-41-00-810-809-A
[8]
Aircraft Electrical Circuits cannot be supplied from the External Power -
24-41-00-810-810-A
[8]
Failure of the Ground Auxiliary Power Control Unit -
24-41-00-810-811-A
[8]
Failure of the Interlock Circuit (External Power / GAPCU) -
24-41-00-810-812-A
[8]
Failure of the External Power -
24-41-00-810-813-A
[8]
Failure of the Interlock Signal of the External Power -
24-41-00-810-814-A
[8]
Failure of the External Power and of the POR Sense Wiring of the GAPCU -
24-41-00-810-815-A
[8]
Failure of the Fault Light Circuit of the APU Generator -
24-41-00-810-816-A
[8]
Failure of the Auxiliary Control Circuit of the External Power -
24-41-00-810-817-A
[8]
Failure of the Ground/Flight signal Between the GAPCU and the LGCIU -
24-41-00-810-818-A
[8]
Failure of the EPC Control Circuit -
24-41-00-810-819-A
[8]
Failure of the External Power Wiring or Interlock Protection -
24-41-00-810-820-A
[8]
Failure of the Pin Programming of the GAPCU -
24-41-00-810-821-A
[8]
Failure of the External Power POR-Wiring or Interlock Protection -
24-41-00-810-822-A
[8]
Failure of the External Power Feeders or External Power POR-Wiring -
24-41-00-810-823-A
[8]
Failure of the External Power Feeders and External Power POR-Wiring -
24-41-00-810-824-A
[8]
Failure of the APU Generator Feeders or APU Generator POR-Wiring -
24-41-00-810-825-A
[8]
Failure of the ARINC 429 Bus betwwen the GAPCU and the CFDIU -
24-41-00-810-826-A
[8]
Impossibility to Connect the External Power on the Aircraft -
24-41-00-810-827-A
[8]
Failure of the External Power Plug or Interlock Wiring -
24-41-00-810-828-A
[8]
Failure of the External Power or the Phase A of the POR Sense Wiring -
24-41-00-810-829-A
[8]
Failure of the External Power Interlock-Wiring -
24-41-00-810-830-A
[8]
Failure of the External Power Because of an Unbalance -
24-41-00-810-832-A
[8]
Failure of the GAPCU in the FAILSAFE Mode -
24-41-00-810-833-A
[8]
Failure of the Ground Power Unit to Supply the Aircraft Electrical Circuits -
24-41-00-810-834-A
[8]
Failure of the GAPCU -
24-41-00-810-835-A
[8]
Failure Message Related to External Power Given in PFRs that Follow in Sequence
-
24-41-00-810-801-A
[8]