W DOC AIRBUS | TSM A320F

Loss of the CFDIU Discrete Signal to the GPCU


TASK 24-41-00-810-808-A
Loss of the CFDIU Discrete Signal to the GPCU


1. Possible Causes
  • GPCU [1XG]
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-41-00-740-004
Operational Check of the GPCU via the CFDS
AMM 24-41-34-000-001
Removal of the Ground Power Control Unit (GPCU)
AMM 24-41-34-400-001
Installation of the Ground Power Control Unit (GPCU)
ASM 313206
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
3. Fault Confirmation
Subtask 24-41-00-710-064-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational check of the GPCU with the CFDS AMM 24-41-00-740-004.
4. Fault Isolation
Subtask 24-41-00-810-057-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CHECK GPCU PIN A4B CFDIU 1TW PIN A9K WIRING:
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring from the pin AA/4B of the GPCU (1XG) to the pin AA/9K of the CFDIU (1TW) ASM 313206.
Subtask 24-41-00-710-065-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:26:53 UTC