Failure of the RS422 Electrical Connection between the GPCU and the GCU 2


TASK 24-41-00-810-807-A
Failure of the RS422 Electrical Connection between the GPCU and the GCU 2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-22-34-000-001
Removal of the GCU-1(2)
AMM 24-22-34-400-001
Installation of the GCU-1(2)
AMM 24-41-00-740-004
Operational Check of the GPCU via the CFDS
ASM 244102
AMM 24-41-34-000-001
Removal of the Ground Power Control Unit (GPCU)
AMM 24-41-34-400-001
Installation of the Ground Power Control Unit (GPCU)
3. Fault Confirmation
Subtask 24-41-00-710-061-A ** ON A/C NOT FOR ALL
A. Test
Do the operational check of the GPCU with the CFDS AMM 24-41-00-740-004.
4. Fault Isolation
Subtask 24-41-00-810-056-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CHECK SERIAL LINK GPCU TO GCU 2:
  • do a check of the wiring for short to ground or open circuit between respectively the GPCU pins A/12D, A/13D and the GCU 2 pins B/14C, B/14D ASM 244102.
   (1) If the wiring is not correct:
  • repair it.
   (2) If the wiring is correct:
   (3) If the fault continues:
Subtask 24-41-00-710-062-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.