W DOC AIRBUS | TSM A320F

Failure of the Ground Auxiliary Power Control Unit


TASK 24-41-00-810-810-A
Failure of the Ground Auxiliary Power Control Unit


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-41-00-740-002
Operational Check of the GAPCU via the CFDS
AMM 24-41-34-000-001
Removal of the Ground Power Control Unit (GPCU)
AMM 24-41-34-400-001
Installation of the Ground Power Control Unit (GPCU)
3. Fault Confirmation
Subtask 24-41-00-740-050-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the GAPCU AMM 24-41-00-740-002.
     (a) If the BITE test gives the message TEST FAILED:
  • do the trouble shooting given in Para 4.A.
     (b) If the BITE test gives the message TEST PASSED:
  • stop the trouble shooting.
4. Fault Isolation
Subtask 24-41-00-810-059-A ** ON A/C NOT FOR ALL
A. If the BITE test gives the message TEST FAILED:
  • Push the line key adjacent to the TEST FAILED message.
   (1) If the maintenance message GAPCU (24XG) comes into view:
  • Replace the MODULE DIODE UNIT [1164VD] .
     (a) If the fault continues:
Subtask 24-41-00-810-059-C ** ON A/C NOT FOR ALL
A. If the BITE test gives the message TEST FAILED:
  • Push the line key adjacent to the TEST FAILED message.
   (1) If the maintenance message GAPCU (24XG) comes into view:
Subtask 24-41-00-740-051-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.