W DOC AIRBUS | TSM A320F

Failure of the Ground Power Control Unit


TASK 24-41-00-810-801-A
Failure of the Ground Power Control Unit


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-41-00-740-004
Operational Check of the GPCU via the CFDS
AMM 24-41-34-000-001
Removal of the Ground Power Control Unit (GPCU)
AMM 24-41-34-400-001
Installation of the Ground Power Control Unit (GPCU)
3. Fault Confirmation
Subtask 24-41-00-710-050-A ** ON A/C NOT FOR ALL
A. Test
Do the operational check of the GPCU with the CFDS AMM 24-41-00-740-004.
4. Fault Isolation
Subtask 24-41-00-810-050-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message GPCU:
Subtask 24-41-00-710-063-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:26:53 UTC