Failure of the Ground Power Control Unit
TASK 24-41-00-810-801-A
Failure of the Ground Power Control Unit
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-41-00-710-050-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 24-41-00-810-050-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:53 UTC
Failure of the Ground Power Control Unit
1. Possible Causes
- GPCU [1XG]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-41-00-740-004 | Operational Check of the GPCU via the CFDS |
| AMM 24-41-34-000-001 | Removal of the Ground Power Control Unit (GPCU) |
| AMM 24-41-34-400-001 | Installation of the Ground Power Control Unit (GPCU) |
Subtask 24-41-00-710-050-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 24-41-00-810-050-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message GPCU:
Subtask 24-41-00-710-063-A ** ON A/C NOT FOR ALL - replace the GPCU [1XG] AMM 24-41-34-000-001 and AMM 24-41-34-400-001.
B. Do the test given in Para. 3.A.