W DOC AIRBUS | TSM A320F

Failure of the Pin Programming of the GAPCU


TASK 24-41-00-810-820-A
Failure of the Pin Programming of the GAPCU


1. Possible Causes
  • GAPCU [24XG]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-41-00-740-002
Operational Check of the GAPCU via the CFDS
ASM 244101
AMM 24-41-34-000-001
Removal of the Ground Power Control Unit (GPCU)
AMM 24-41-34-400-001
Installation of the Ground Power Control Unit (GPCU)
3. Fault Confirmation
Subtask 24-41-00-740-058-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the GAPCU AMM 24-41-00-740-002.
     (a) If the BITE test gives the message TEST FAILED:
  • do the trouble shooting given in Para 4.A.
     (b) If the BITE test gives the message TEST PASSED:
  • do the trouble shooting given in Para 4.B.
4. Fault Isolation
Subtask 24-41-00-810-084-A ** ON A/C NOT FOR ALL
A. If the BITE test gives the message TEST FAILED:
  • push the line key adjacent to the TEST FAILED message.
   (1) If the maintenance message GAPCU (24XG) comes into view:
Subtask 24-41-00-810-063-A ** ON A/C NOT FOR ALL
B. If the BITE test gives the message TEST PASSED:
  • do a check of the pin programming wiring ASM 244101 of the GAPCU:
    . pin A/4G connected to ground
    . pins A/3E, A/5E and A/5A not connected.
NOTE: The wiring diagram of the aircraft interface with the pin programming connections is necessary to do the trouble shooting procedure.
   (1) If the wiring is not correct:
  • repair or replace as necessary.
   (2) If the wiring is correct:
Subtask 24-41-00-740-059-A ** ON A/C NOT FOR ALL
C. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:26:54 UTC