Detailed Visual Inspection (DVI) of the Stator Guide Vane (SGV) Inner Liner [PW11]
TASK 72-21-12-220-801-A
Detailed Visual Inspection (DVI) of the Stator Guide Vane (SGV) Inner Liner
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 72-21-12-941-053-A ** ON A/C NOT FOR ALL
Subtask 72-21-12-220-051-A ** ON A/C NOT FOR ALL
Subtask 72-21-12-410-054-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:49:07 UTC
Detailed Visual Inspection (DVI) of the Stator Guide Vane (SGV) Inner Liner
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 400
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | 1 | FLASHLIGHT |
| No specific | 1 | GLOVES - PROTECTIVE |
| No specific | 1 | MAT - PROTECTIVE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 71-13-00-010-802-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-802-A | Closing of the Fan Cowl Doors |
| TASK 72-21-08-000-801-A | Removal of the Fan Exit Liner Segments |
| TASK 72-21-08-400-801-A | Installation of the Fan Exit Liner Segments |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-30-00-440-805-A | Reactivation of the Thrust Reverser System after Ground Maintenance |
| TASK 78-36-00-010-802-A | Opening of the Thrust Reverser Cowl-Doors |
| TASK 78-36-00-410-802-A | Closing of the Thrust Reverser Cowl-Doors |
Subtask 72-21-12-941-053-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 72-21-12-010-056-A ** ON A/C NOT FOR ALL (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR.
(2) Put the ACCESS PLATFORM 2M (6 FT) in position.
Subtask 72-21-12-040-053-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR.
(2) Put the ACCESS PLATFORM 2M (6 FT) in position.
C. Deactivation of the Thrust Reverser for Maintenance
Subtask 72-21-12-010-057-A ** ON A/C NOT FOR ALL WARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
(1) Do the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-805). D. Get Access
(1) Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL 462AR.
4. Procedure(1) Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL 462AR.
Subtask 72-21-12-220-051-A ** ON A/C NOT FOR ALL
A. Detailed Visual Inspection (DVI) of the Stator Guide Vane (SGV) Inner Liner
(1) Do a DVI of the SGV inner liner for damage. Use a FLASHLIGHT if necessary.
(a) Wear GLOVES - PROTECTIVE when you touch the fan blades.
(b) Put the MAT - PROTECTIVE inside the air intake cowl.
Table 1 - SGV Inner Liner - Visual Inspection
(2) Remove the MAT - PROTECTIVE from the air inlet cowl.
5. Close-up(1) Do a DVI of the SGV inner liner for damage. Use a FLASHLIGHT if necessary.
(a) Wear GLOVES - PROTECTIVE when you touch the fan blades.
(b) Put the MAT - PROTECTIVE inside the air intake cowl.
Table 1 - SGV Inner Liner - Visual Inspection
| EXAMINE | DAMAGE | DISPOSITION |
|---|---|---|
| Liner flow path surface for: | Cracks | Not permitted. Replace the damaged liner before next flight (Ref. AMM TASK 72-21-08-000-801) and (Ref. AMM TASK 72-21-08-400-801). |
| | Nicks, dents or scratches not more than 0.039 in. (0.991 mm) maximum depth, all quantities | Permitted |
| | Nicks, dents or scratches more than 0.039 in. (0.991 mm) maximum depth | Not permitted. Replace the damaged liner in 50 flight cycles (Ref. AMM TASK 72-21-08-000-801) and (Ref. AMM TASK 72-21-08-400-801). |
| | Surface erosion not more than 0.030 in. (0.762 mm) maximum depth, all quantities | Permitted |
| | Surface erosion more than 0.030 in. (0.762 mm) maximum depth | Not permitted. Replace the damaged liner in 50 flight cycles (Ref. AMM TASK 72-21-08-000-801) and (Ref. AMM TASK 72-21-08-400-801). |
| | Punctures, holes or missing materials | Not permitted. Replace the damaged liner in ten flight cycles (Ref. AMM TASK 72-21-08-000-801) and (Ref. AMM TASK 72-21-08-400-801). |
| Rubber fillet for: | Wear, peeling, detachment or missing material, all quantities | Permitted. Loose rubber fillets may be cut away, which are possible to be released from the liner. |
Subtask 72-21-12-410-054-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL 462AR.
Subtask 72-21-12-440-052-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL 462AR.
B. Do the reactivation of the thrust reverser system after maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 72-21-12-410-055-A ** ON A/C NOT FOR ALL
Detailed Visual Inspection (DVI) of the Stator Guide Vane (SGV) Inner Liner