Reactivation of the Thrust Reverser System after Ground Maintenance [PW11]
TASK 78-30-00-440-805-A
Reactivation of the Thrust Reverser System after Ground Maintenance
Self explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 78-30-00-941-083-A ** ON A/C NOT FOR ALL
Subtask 78-30-00-440-064-A ** ON A/C NOT FOR ALL
Subtask 78-30-00-410-072-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:51:35 UTC
Reactivation of the Thrust Reverser System after Ground Maintenance
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
WEAR APPLICABLE PERSONAL PROTECTIVE EQUIPMENT (PPE) WHEN YOU DO THIS TASK. BEFORE YOU USE PPE, READ, UNDERSTAND AND OBEY ALL INSTRUCTIONS FOR ITS USE. THESE INSTRUCTIONS INCLUDE INSTRUCTIONS FROM THE MANUFACTURER, YOUR EMPLOYER AND GOVERNMENT REGULATIONS. YOU CAN GET INJURED IF YOU DO NOT USE PPE. GET INSTRUCTIONS FROM YOUR EMPLOYER ON WHICH PPE IS NECESSARY.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 71-13-00-010-802-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-802-A | Closing of the Fan Cowl Doors |
Subtask 78-30-00-941-083-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833)
Subtask 78-30-00-010-087-A ** ON A/C NOT FOR ALL (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833)
B. Get Access
(1) Make sure that the oil tank access-door on the left fan cowl-door or the fan cowl doors is/are open (Ref. AMM TASK 71-13-00-010-802).
4. Procedure(1) Make sure that the oil tank access-door on the left fan cowl-door or the fan cowl doors is/are open (Ref. AMM TASK 71-13-00-010-802).
Subtask 78-30-00-440-064-A ** ON A/C NOT FOR ALL
A. Reactivation of the Thrust Reverser after Ground Maintenance
(1) Turn the lever (1) to the inhibit position for easy removal of the locking pin (2).
(2) Remove the lockout pin (2) from lockout pin inhibited location of the inhibit cable handle assembly.
(3) Let the lever (1) on the inhibit cable handle assembly go back to the active position.
(4) Stow the lockout pin (2) in the lockout pin storage location of the inhibit cable handle assembly.
5. Close-up(1) Turn the lever (1) to the inhibit position for easy removal of the locking pin (2).
(2) Remove the lockout pin (2) from lockout pin inhibited location of the inhibit cable handle assembly.
(3) Let the lever (1) on the inhibit cable handle assembly go back to the active position.
(4) Stow the lockout pin (2) in the lockout pin storage location of the inhibit cable handle assembly.
Subtask 78-30-00-410-072-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the oil tank access-door or the fan cowl doors (Ref. AMM TASK 71-13-00-410-802).
(3) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the oil tank access-door or the fan cowl doors (Ref. AMM TASK 71-13-00-410-802).
(3) Remove the WARNING NOTICE(S).
Deactivation/Reactivation of the Thrust Reverser for/after Ground Maintenance