Detailed Inspection of Pylon compartment C drain system.
TASK 54-50-00-220-002-A
Detailed Inspection of Pylon compartment C drain system.
Refer to the MPD TASK: 545000-04
DETAILED INSPECTION OF PYLON COMPARTMENT C DRAIN SYSTEM.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 54-50-00-941-066-A ** ON A/C NOT FOR ALL
Subtask 54-50-00-210-058-A ** ON A/C NOT FOR ALL
Subtask 54-50-00-440-055-A ** ON A/C NOT FOR ALL Subtask 54-50-00-410-057-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:59:07 UTC
Detailed Inspection of Pylon compartment C drain system.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Refer to the MPD TASK: 545000-04
DETAILED INSPECTION OF PYLON COMPARTMENT C DRAIN SYSTEM.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| No specific | 1 | FLASHLIGHT |
| No specific | 1 | MIRROR - INSPECTION |
| No specific | 1 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 410 | ENG 1 PYLON BOX AND FORWARD FAIRING |
| 420 | ENG 2 PYLON BOX AND FORWARD FAIRING |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 54-56-00-000-001-A | Removal of the Lower Fairing |
| TASK 54-56-00-000-002-A | Removal of the Lower Fairing |
| TASK 54-56-00-400-001-A | Installation of the Lower Fairing |
| TASK 54-56-00-400-002-A | Installation of the Lower Fairing |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-440-012-A | Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
Subtask 54-50-00-941-066-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 54-50-00-040-056-A ** ON A/C NOT FOR ALL Subtask 54-50-00-010-056-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
C. Get Access
(1) Put an ACCESS PLATFORM 1M(3 FT) in position at zone 410 or 420.
(2) Remove the Lower Aft Pylon Fairing (Ref. AMM TASK 54-56-00-000-001).
Subtask 54-50-00-040-056-B ** ON A/C NOT FOR ALL Subtask 54-50-00-010-056-B ** ON A/C NOT FOR ALL (1) Put an ACCESS PLATFORM 1M(3 FT) in position at zone 410 or 420.
(2) Remove the Lower Aft Pylon Fairing (Ref. AMM TASK 54-56-00-000-001).
E. Get Access
(1) Put an ACCESS PLATFORM 1M(3 FT) in position at zone 410 or 420.
(2) Remove the Lower Aft Pylon Fairing (Ref. AMM TASK 54-56-00-000-002).
4. Procedure(1) Put an ACCESS PLATFORM 1M(3 FT) in position at zone 410 or 420.
(2) Remove the Lower Aft Pylon Fairing (Ref. AMM TASK 54-56-00-000-002).
Subtask 54-50-00-210-058-A ** ON A/C NOT FOR ALL
A. Inspection
(1) Visual inspection of the pylon drain system.
(a) Do a detailed visual inspection of the drain line.
(b) Make sure that the drain inlets are not obstructed. Use a FLASHLIGHT and a MIRROR - INSPECTION if necessary.
(c) Examine the line to make sure that there are no cracks, marks, corrosion or other damage.
(d) Make sure that the lines are correctly attached.
5. Close-up(1) Visual inspection of the pylon drain system.
(a) Do a detailed visual inspection of the drain line.
(b) Make sure that the drain inlets are not obstructed. Use a FLASHLIGHT and a MIRROR - INSPECTION if necessary.
(c) Examine the line to make sure that there are no cracks, marks, corrosion or other damage.
(d) Make sure that the lines are correctly attached.
Subtask 54-50-00-440-055-A ** ON A/C NOT FOR ALL Subtask 54-50-00-410-057-A ** ON A/C NOT FOR ALL
B. Close Access
(1) Install the Lower Aft Pylon Fairing (Ref. AMM TASK 54-56-00-400-001).
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
Subtask 54-50-00-440-055-B ** ON A/C NOT FOR ALL Subtask 54-50-00-410-057-B ** ON A/C NOT FOR ALL (1) Install the Lower Aft Pylon Fairing (Ref. AMM TASK 54-56-00-400-001).
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
D. Close Access
(1) Install the Lower Aft Pylon Fairing (Ref. AMM TASK 54-56-00-400-002).
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
(1) Install the Lower Aft Pylon Fairing (Ref. AMM TASK 54-56-00-400-002).
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
Visual Inspection of Pylon Drain System