Operational Test of the Toilet Unit


TASK 38-31-00-710-009-A
Operational Test of the Toilet Unit


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 38-10-00-614-001-A
Pressurization of the Potable Water System from a Ground Air Supply
TASK 38-10-00-614-002-A
Depressurization of the Potable Water System
3. Job Set-up
Subtask 38-31-00-861-060-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 38-31-00-010-072-A
B. Get Access
   (1) Get access to the lavatory.
   (2) Make sure that the waste service-panel door 172AR is closed.
Subtask 38-31-00-865-124-A
C. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-E34MGA04
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-D39MGA03
** ON A/C ALL
2001VUVACU TOIL SYS-LAV PWR-A32MGA01
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-G34MGA04
2001VUVACU TOIL SYS-LAV PWR-F39MGA03
2001VUVACU TOIL SYS-LAV PWR-D45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L23MGA05
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-M34MGA04
Subtask 38-31-00-614-052-A
D. Pressurize the potable water system (Ref. AMM TASK 38-10-00-614-001).
4. Procedure
Subtask 38-31-00-710-062-A ** ON A/C NOT FOR ALL
A. Do this test.
ACTION
RESULT
1.In all lavatories:
  • push each flush switch 51MG with a time delay of 15 +3 -3 s.
In the vacuum toilet system:
  • the vacuum generator 37MG operates.
  • approx. 0.2 l (0.05 USgal) of water flows into the toilet bowl.
  • air flows out of the ventilation port of the vacuum generator.
  • the toilet flush valve opens and the suction removes the water.
2.At the waste service panel:
  • open the waste service-panel door 172AR.

3.In two lavatories:
  • push the flush switch 51MG.
In the vacuum system:
  • the vacuum generator 37MG does not operate.
  • the toilet does not flush.
4.At the waste service panel:
  • close the waste service-panel door 172AR.

5.In the lavatory:
  • push the flush switch 51MG.
In the vacuum toilet system:
  • the vacuum generator 37MG operates.
  • the toilet flushes correctly.
Subtask 38-31-00-710-062-C ** ON A/C NOT FOR ALL
A. Do this test.
NOTE: Incorrect failure messages can show on the MCDU or FAP when a toilet flush occurs flight.
Make sure that no failure messages show on the Previous Flight Report or Last Leg Report before you do this test.
ACTION
RESULT
1.In all lavatories:
  • push each flush switch 51MG with a time delay of 15 +3 -3 s.
In the vacuum toilet system:
  • the vacuum generator 37MG operates.
  • approx. 0.2 l (0.05 USgal) of water flows into the toilet bowl.
  • air flows out of the ventilation port of the vacuum generator.
  • the toilet flush valve opens and the suction removes the water.
2.In two lavatories:
  • push the flush switch of both toilets with a delay of 7 s.
In the vacuum system:
  • the vacuum generator 37MG starts to operate and remains on until both toilets flush are completed.
3.At the waste service panel:
  • open the waste service-panel door 172AR.

4.In two lavatories:
  • push the flush switch 51MG.
In the vacuum system:
  • the vacuum generator 37MG does not operate.
  • the toilet does not flush.
5.At the waste service panel:
  • close the waste service-panel door 172AR.

6.In the lavatory:
  • push the flush switch 51MG.
In the vacuum toilet system:
  • the vacuum generator 37MG operates.
  • the toilet flushes correctly.
5. Close-up
Subtask 38-31-00-614-053-A
A. Release the pressure from the potable water system (Ref. AMM TASK 38-10-00-614-002).
Subtask 38-31-00-410-070-A
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the access platform(s).
Subtask 38-31-00-862-060-A
C. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Subtask 38-31-00-942-063-A
D. Remove the ground support and maintenance equipment, the special and standard tools and all other items.