W DOC AIRBUS | AMM A320F

Installation of the High Pressure (HP) Bleed-Valve Closure Control-Solenoid


TASK 36-11-57-400-001-A
Installation of the High Pressure (HP) Bleed-Valve Closure Control-Solenoid


ZONE: 410
FIN: 4029KS ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 45 and 36 lbf.in (0.51 and 0.41 m.daN ) T
No specific
Torque wrench: range to between 221 and 204 lbf.in (2.50 and 2.31 m.daN ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.V02-126)
lockwire
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
410
ENG 1 PYLON BOX AND FORWARD FAIRING
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 36-11-57-280-010-A
Stage 10 Air Solenoid Valve - P3 Servo Line Purging Procedure
TASK 49-00-00-860-009-A
APU Shutdown by External Power (131-9(A))
TASK 49-00-00-860-009-A-01
APU Shutdown by Batteries (131-9(A))
TASK 70-23-11-911-013-A
General Torque Tightening Techniques
TASK 70-40-11-911-014-A
Locking Devices General Information
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
3. Job Set-up
Subtask 36-11-57-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
   (2) Make sure that the engine shutdown occurred five minutes or more before you do this procedure.
   (3) On AIR COND panel 30VU:
  • Make sure that ENG 1(2) BLEED pushbutton switch is released (the OFF legend comes on)
  • Make sure that the APU BLEED pushbutton switch is released (the ON legend goes off)
  • Make sure that the WARNING NOTICE(S) is/are in the position to tell persons not to operate the pneumatic system.
   (4) On ENG panel 115VU:
  • Make sure that the WARNING NOTICE(S) is/are in the position to tell persons not to start engine 1(2).
   (5) On the HP ground connector:
  • Make sure that the WARNING NOTICE(S) is/are in the position to tell persons not to pressurize the pneumatic system.
   (6) On the ENG section of maintenance panel 50VU:
  • Make sure that the ON legend of ENG/FADEC GND PWR 1(2) pushbutton switch is off
  • Make sure that the WARNING NOTICE(S) is/are in the position to tell persons not to energize FADEC 1(2).
   (7) Make sure that the ACCESS PLATFORM 1M(3 FT) is in the position below the engine.
Subtask 36-11-57-865-051-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 1/CTL3HA1D12
49VUAIR BLEED/ENG 1/MONG2HA1D11
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
Subtask 36-11-57-010-051-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure
Subtask 36-11-57-160-052-A ** ON A/C NOT FOR ALL
A. Purge of the P3 Supply Line
   (1) If you use the APU to energize the electrical circuits, stop the APU:
   (2) In the cockpit, on the SD bleed page:
     (a) Make sure that the pressure and the temperature of the bleed-air duct system are in the ambient conditions.
WARNING: MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING: DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
   (3) Remove the unwanted material from P3 supply line (Ref. AMM TASK 36-11-57-280-010).
NOTE: You can do the purge process after the full equipment is available.
Subtask 36-11-57-420-050-A ** ON A/C NOT FOR ALL
B. Installation of the HP Bleed Valve Closure Control solenoid (4029KS)
   (1) Put the solenoid valve (15) in position on the mounting bracket.
   (2) Attach the solenoid valve to the bracket with the three bolts (14) and the three washers (13).
   (3) TORQUE the three bolts (14) to between 45 and 36 lbf.in (0.51 and 0.41 m.daN ) T (Ref. AMM TASK 70-23-11-911-013).
   (4) Install the tubes.
   (5) Connect the tube (2) to the solenoid valve (15).
   (6) TORQUE the tube (2) union nut to between 221 and 204 lbf.in (2.50 and 2.31 m.daN ) T (Ref. AMM TASK 70-23-11-911-013).
   (7) Safety the tube (2) union nut with lockwire (Material No.V02-126) (Ref. AMM TASK 70-40-11-911-014).
   (8) Put the tube (1) in position.
   (9) Connect the tube (1) union nuts to the solenoid valve (15) and the tee-piece.
   (10) TORQUE the tube (1) union nuts to between 221 and 204 lbf.in (2.50 and 2.31 m.daN ) T (Ref. AMM TASK 70-23-11-911-013).
   (11) Safety the tube (1) union nuts with lockwire (Material No.V02-126) (Ref. AMM TASK 70-40-11-911-014).
   (12) Install the clips.
   (13) Put the clip (5) and the clips (9) in position.
   (14) Attach the clip (5) to the lug with the bolt (3), the washer (4) and the nut (6).
   (15) Attach the clips (9) with the bolt (8), the washer (7) and the nut (10).
   (16) TORQUE the nut (6) to between 45 and 36 lbf.in (0.51 and 0.41 m.daN ) T (Ref. AMM TASK 70-23-11-911-013).
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
   (17) Connect the electrical connector (12) to the solenoid valve (15).
5. Close-up
Subtask 36-11-57-865-052-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 1/CTL3HA1D12
49VUAIR BLEED/ENG 1/MONG2HA1D11
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
Subtask 36-11-57-410-050-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Remove the WARNING NOTICE(S).
   (3) Remove the access platform(s).
Subtask 36-11-57-862-050-A ** ON A/C NOT FOR ALL
C. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002) or (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 01:14:07 UTC