W DOC AIRBUS | AMM A320F

Functional Check of Brake Accumulator System with the Parking Brake not Applied


TASK 32-44-00-720-003-A
Functional Check of Brake Accumulator System with the Parking Brake not Applied


WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
WARNING: MAKE SURE THAT THE CONTROLS AGREE WITH THE POSITION OF THE ITEMS THEY OPERATE BEFORE YOU PRESSURIZE A HYDRAULIC SYSTEM. UNWANTED MOVEMENT OF HYDRAULICALLY OPERATED ITEMS CAN CAUSE SERIOUS INJURY AND/OR DAMAGE.
WARNING: PRESSURIZE ONLY THE HYDRAULIC SYSTEM(S) THAT IS (ARE) NECESSARY FOR THE TASK. ISOLATE THE OTHER HYDRAULIC SYSTEM(S) BEFORE YOU SUPPLY HYDRAULIC POWER TO THE AIRCRAFT.
WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
ZONE: 148
ZONE: 210
ZONE: 730
ZONE: 740
1. Reason for the Job
Refer to the MPD TASK: 324500-03
FUNCTIONAL CHECK OF BRAKE ACCUMULATOR SYSTEM WITH THE PARKING BRAKE NOT APPLIED
You can also do this task for the leak test of the brake accumulator system during the related troubleshooting procedure.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
148
MAIN GEAR WELL AND HYDRAULIC COMPARTMENT
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
730
LEFT MAIN LANDING GEAR & DOORS
740
RIGHT MAIN LANDING GEAR & DOORS
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 29-00-00-864-001-A
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
TASK 32-44-11-200-001-A
Functional Check of Parking/Emergency Brake Accumulator by Reading the Charge Pressure on the Accumulator Gauge
TSM 32-44-00-810-808
(for corrective action)
3. Job Set-up
Subtask 32-44-00-865-057-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUL/G/Y BRK/PRESS/IND61GGC10
** ON A/C NOT FOR ALL
49VUABCU &/Y BRK/PRESS IND61GGC10
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN30
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN31
** ON A/C ALL
123VUY HYD/ELEC/PUMP3802GXAB06
Subtask 32-44-00-860-059-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) On panel 400VU, make sure that the landing-gear control lever is in the DOWN position.
   (2) On panel 110VU, make sure that the parking brake control-switch is in the OFF position.
   (3) Make sure that the CAPT and F/O brake pedals are released.
   (4) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (5) Make sure that the Green and Yellow hydraulic systems are depressurized
(Ref. AMM TASK 29-00-00-864-001).
   (6) Do a check of the accumulator charging pressure and make sure that it is 100 bar (1450 psi) at 20 DEG.C (68 DEG.F) (Ref. AMM TASK 32-44-11-200-001).
     (a) Do not close the main door of the right MLG.
   (7) On overhead panel 40VU, push and release the PTU/AUTO pushbutton switch. Make sure that the OFF legend comes on.
   (8) On overhead panel 40VU, push and release the YELLOW/ELEC PUMP pushbutton switch to pressurize the brake accumulator system to 206 bar (2988 psi). The brake accumulator pressure is shown on the ACCU PRESS indication on the triple pressure indicator on panel 400VU.
   (9) On panel 110VU, put the parking brake control-switch in the ON position.
   (10) On overhead panel 40VU, push and release the YELLOW/ELEC PUMP pushbutton switch. Before you do other steps on the alternate braking system, wait a minimum of one hour.
NOTE: This is to make sure that the fluid temperature is almost the same as the ambient temperature.
     (a) Do not push the brake pedals during this time.
   (11) On panel 110VU, put the parking brake control-switch in the OFF position.
   (12) On overhead panel 40VU, push and release the YELLOW/ELEC PUMP pushbutton switch to pressurize the brake accumulator system to 206 bar (2988 psi). The brake accumulator pressure is shown on the ACCU PRESS indication on the triple pressure indicator on panel 400VU.
   (13) On overhead panel 40VU, push and release the YELLOW/ELEC PUMP pushbutton switch.
Subtask 32-44-00-860-059-B ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) On panel 400VU, make sure that the landing-gear control lever is in the DOWN position.
   (2) On panel 110VU, make sure that the parking brake control-switch is in the OFF position.
   (3) Make sure that the CAPT and F/O brake pedals are released.
   (4) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (5) Make sure that the Green and Yellow hydraulic systems are depressurized
(Ref. AMM TASK 29-00-00-864-001).
   (6) Do a check of the accumulator charging pressure and make sure that it is70 bar (1015 psi) at 20 DEG.C (68 DEG.F) (Ref. AMM TASK 32-44-11-200-001).
     (a) Do not close the main door of the right MLG.
   (7) On overhead panel 40VU, push and release the PTU/AUTO pushbutton switch. Make sure that the OFF legend comes on.
   (8) On overhead panel 40VU, push and release the YELLOW/ELEC PUMP pushbutton switch to pressurize the brake accumulator system to 206 bar (2988 psi). The brake accumulator pressure is shown on the ACCU PRESS indication on the triple pressure indicator on panel 400VU.
   (9) On panel 110VU, put the parking brake control-switch in the ON position.
   (10) On overhead panel 40VU, push and release the YELLOW/ELEC PUMP pushbutton switch. Before you do other steps on the alternate braking system, wait a minimum of one hour.
NOTE: This is to make sure that the fluid temperature is almost the same as the ambient temperature.
     (a) Do not push the brake pedals during this time.
   (11) On panel 110VU, put the parking brake control-switch in the OFF position.
   (12) On overhead panel 40VU, push and release the YELLOW/ELEC PUMP pushbutton switch to pressurize the brake accumulator system to 206 bar (2988 psi). The brake accumulator pressure is shown on the ACCU PRESS indication on the triple pressure indicator on panel 400VU.
   (13) On overhead panel 40VU, push and release the YELLOW/ELEC PUMP pushbutton switch.
Subtask 32-44-00-860-059-C ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) On panel 400VU, make sure that the landing-gear control lever is in the DOWN position.
   (2) On panel 110VU, make sure that the parking brake control-switch is in the OFF position.
   (3) Make sure that the CAPT and F/O brake pedals are released.
   (4) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (5) Make sure that the Green and Yellow hydraulic systems are depressurized
(Ref. AMM TASK 29-00-00-864-001).
   (6) Do a check of the accumulator charging pressure and make sure that it is 80 bar (1160 psi) at 20 DEG.C (68 DEG.F) (Ref. AMM TASK 32-44-11-200-001).
     (a) Do not close the main door of the right MLG.
   (7) On overhead panel 40VU, push and release the PTU/AUTO pushbutton switch. Make sure that the OFF legend comes on.
   (8) On overhead panel 40VU, push and release the YELLOW/ELEC PUMP pushbutton switch to pressurize the brake accumulator system to 206 bar (2988 psi). The brake accumulator pressure is shown on the ACCU PRESS indication on the triple pressure indicator on panel 400VU.
   (9) On panel 110VU, put the parking brake control-switch in the ON position.
   (10) On overhead panel 40VU, push and release the YELLOW/ELEC PUMP pushbutton switch. Before you do other steps on the alternate braking system, wait a minimum of one hour.
NOTE: This is to make sure that the fluid temperature is almost the same as the ambient temperature.
     (a) Do not push the brake pedals during this time.
   (11) On panel 110VU, put the parking brake control-switch in the OFF position.
   (12) On overhead panel 40VU, push and release the YELLOW/ELEC PUMP pushbutton switch to pressurize the brake accumulator system to 206 bar (2988 psi). The brake accumulator pressure is shown on the ACCU PRESS indication on the triple pressure indicator on panel 400VU.
   (13) On overhead panel 40VU, push and release the YELLOW/ELEC PUMP pushbutton switch.
Subtask 32-44-00-941-055-A
C. Safety Precautions
   (1) Put the WARNING NOTICE(S) in position to tell persons not to:
  • Pressurize the Green and Yellow hydraulic systems.
  • Operate the landing-gear control lever.
4. Procedure
Subtask 32-44-00-720-053-A ** ON A/C NOT FOR ALL
A. Functional Check of Brake Accumulator System with the Parking Brake not Applied
   (1) Do not push the brake pedals during the functional check of brake accumulator system.
   (2) In relation to the ambient temperature (Tamb.), make sure that the pressure read on the accumulator pressure gage is not less than the limits (Plimit) shown below:
------------------ ------------------ Tamb
Plimit --------- After 30min --------- bar
Plimit --------- After 30min --------- PSI
Plimit --------- After 45min --------- bar
Plimit --------- After 45min --------- PSI
Plimit --------- After 60min --------- bar
Plimit -------- After 60min -------- PSI
Tamb > 20 deg.C
(Tamb > 68 deg.F)
152
2200
141
2050
131
1900
0 < Tamb < 20 deg.C
(32 < Tamb < 68 deg.F)
159
2300
148
2150
138
2000
-10 < Tamb < 0 deg.C
(14 < Tamb < 32 deg.F)
176
2550
165
2400
159
2300
Tamb < -10 deg.C
(Tamb < 14 deg.F)
183
2650
176
2550
169
2450
   (3) If two pressure values out of the three pressure values measured are less than the minimum values, do a check of the system to find the leak TSM 32-44-00-810-808.
   (4) If the ambient temperature is more than 40 deg.C (104.00 deg.F) and if two of the three pressure values measured are less than the minimum pressure values, do a second test. We recommend that you do the test at an ambient temperature near 20 deg.C (68.00 deg.F).
Subtask 32-44-00-720-053-B ** ON A/C NOT FOR ALL
A. Functional Check of Brake Accumulator System with the Parking Brake not Applied
   (1) Do not push the brake pedals during the functional check of brake accumulator system.
   (2) In relation to the ambient temperature (Tamb.), make sure that the pressure read on the accumulator pressure gage is not less than the limits (Plimit) shown below:
------------------ ------------------ Tamb
Plimit --------- After 30min --------- bar
Plimit --------- After 30min --------- PSI
Plimit --------- After 45min --------- bar
Plimit --------- After 45min --------- PSI
Plimit --------- After 60min --------- bar
Plimit -------- After 60min -------- PSI
Tamb > 20 deg.C
(Tamb > 68 deg.F)
138
2000
124
1800
114
1650
0 < Tamb < 20 deg.C
(32 < Tamb < 68 deg.F)
145
2100
134
1950
124
1800
(-10 < Tamb < 0 deg.C)
(14 < Tamb < 32 deg.F)
165
2400
152
2200
145
2100
Tamb < -10 deg.C
(Tamb < 14 deg.F)
176
2550
169
2450
159
2300
   (3) If two pressure values out of the three pressure values measured are less than the minimum values, do a check of the system to find the leak TSM 32-44-00-810-808.
   (4) If the ambient temperature is more than 40 deg.C (104.00 deg.F) and if two of the three pressure values measured are less than the minimum pressure values, do a second test. We recommend that you do the test at an ambient temperature near 20 deg.C (68.00 deg.F).
Subtask 32-44-00-720-053-C ** ON A/C NOT FOR ALL
A. Functional Check of Brake Accumulator System with the Parking Brake not Applied
   (1) Do not push the brake pedals during the functional check of brake accumulator system.
   (2) Make sure that the pressure read on the accumulator pressure gage is not less than the limits (Plimit) shown below:
-------------------------------------------------------------------------------
! ! PARKING BRAKE NOT APPLIED !
! !----------------------------------------------------------!
! ! After 30min ! After 45min ! After 60min !
! !-------------------!-------------------!------------------!
! ! bar ! PSI ! bar ! PSI ! bar ! PSI !
-------------------------------------------------------------------------------
! Plimit ! 190 ! 2750 ! 185 ! 2700 ! 182 ! 2650 !
-------------------------------------------------------------------------------

   (3) If two pressure values out of the three pressure values measured are less than the minimum values, do a check of the system to find the leak TSM 32-44-00-810-808.
   (4) If the ambient temperature is more than 40 deg.C (104.00 deg.F) and if two of the three pressure values measured are less than the minimum pressure values, do a second test. We recommend that you do the test at an ambient temperature near 20 deg.C (68.00 deg.F).
Subtask 32-44-00-860-060-A
B. Aircraft Maintenance Configuration
   (1) On overhead panel 40VU, push and release the PTU/AUTO pushbutton switch.
     (a) Make sure that the OFF legend goes off.
   (2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Subtask 32-44-00-410-053-A
C. Close Access
   (1) Close the main door of the right MLG (Ref. AMM TASK 32-12-00-410-001).
   (2) Make sure that the work area is clean and clear of tools and other items.
5. Close-up
Subtask 32-44-00-942-054-A
A. Removal of Equipment
   (1) Remove the WARNING NOTICE(S).
   (2) Remove all the fixtures, tools, test and support equipment used during this procedure.
[Rev.10 from 2021] 2026.04.01 00:49:24 UTC