W DOC AIRBUS | AMM A320F

Deactivation of the EIS DMC Selector Switch


TASK 31-68-00-040-003-A
Deactivation of the EIS DMC Selector Switch


ZONE: 210
1. Reason for the Job
MMEL 31-68-04A
EIS DMC SWITCHING SELECTOR ON THE CENTER PEDESTAL (FAA ONLY)
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
3. Job Set-up
Subtask 31-68-00-860-056-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
Subtask 31-68-00-865-052-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUEIS/PFD CAPT/SPLY11WT1E03
** ON A/C NOT FOR ALL
49VUEIS/RLY/BOX/CAPT17WT1E08
** ON A/C NOT FOR ALL
49VUEIS/ECAM/CTL/PNL15WTE12
49VUEIS/DMC1/SPLY10WT1E11
49VUEIS/DMC3/STBY/SPLY14WT1E10
49VUEIS/DMC1/SWTG21WT1E09
** ON A/C ALL
49VUEIS/DMC3/SWTG21WT3E07
49VUEIS/ECAM DU/UPPER/SWTG24WT1E06
49VUEIS/ECAM DU/UPPER/SPLY13WT1E05
49VUEIS/PFD CAPT/SWTG22WT1E04
49VUEIS/ND CAPT/SWTG23WT1E02
49VUEIS/ND CAPT/SPLY12WT1E01
** ON A/C NOT FOR ALL
49VUEIS/PFD/CAPT/SPLY11WT1E03
** ON A/C NOT FOR ALL
49VUEIS/ECAM/CTL/PNL15WTE11
49VUEIS/DMC1/SPLY10WT1E10
49VUEIS/DMC3/STBY/SPLY14WT1E09
49VUEIS/DMC1/SWTG21WT1E08
** ON A/C NOT FOR ALL
121VUEIS/RLY/BOX/F/O17WT2R07
** ON A/C ALL
121VUEIS/DMC3/SPLY10WT3Q09
121VUEIS/DMC2/SPLY10WT2Q08
121VUEIS/ECAM DU/LOWER/SPLY13WT2R11
121VUEIS/ECAM DU/LOWER/SWTG24WT2R10
121VUEIS/DMC2/SWTG21WT2R08
121VUEIS/ND/F/O/SWTG23WT2R06
121VUEIS/PFD/F/O/SWTG22WT2R05
121VUEIS/ND/F/O12WT2R04
121VUEIS/PFD/F/O11WT2R03
122VUELEC/AC/BUS1/CTL17XN1V25
Subtask 31-68-00-860-058-A
C. Aircraft Maintenance Configuration
   (1) Do the EIS Start Procedure (Ref. AMM TASK 31-60-00-860-001)
   (2) On the center pedestal, on the SWITCHING panel 8VU, make sure that the EIS DMC selector switch is in the NORM position.

4. Procedure
Subtask 31-68-00-710-052-A ** ON A/C NOT FOR ALL
A. Check of the EIS DMC switch
ACTION
RESULT
1.On C/B panel 49VU:

  • open the circuit breaker 10WT1
A diagonal line comes into view on the CAPT PFD and ND and on the upper ECAM DU.
On the lower ECAM DU, the EIS DMC1 FAULT message is displayed.
  • close the circuit breaker 10WT1
The related images of each DU come into view.
2.On C/B panel 121VU:

  • open the circuit breaker 10WT2
A diagonal line comes into view on the F/O PFD and ND and on the lower ECAM DU.
On the upper ECAM DU, the EIS DMC2 FAULT message is displayed.
  • close the circuit breaker 10WT2
The related images of each DU come into view.
Subtask 31-68-00-710-052-B ** ON A/C NOT FOR ALL
A. Check of the EIS DMC switch
ACTION
RESULT
1.On C/B panel 49VU:

  • open the circuit breaker 10WT1
An INVALID DATA message comes into view on the CAPT PFD and ND
On the lower ECAM DU, the EIS DMC1 FAULT message is displayed.
  • close the circuit breaker 10WT1
After 35s, the related images of each DU come into view.
2.On C/B panel 121VU:

  • open the circuit breaker 10WT2
An INVALID DATA message comes into view on the F/O PFD and ND
On the upper ECAM DU, the EIS DMC2 FAULT message is displayed.
  • close the circuit breaker 10WT2
After 35s, the related images of each DU come into view.
Subtask 31-68-00-020-053-A
B. Deactivation of the EIS DMC selector switch
   (1) Make a mark on the panel 8VU close to the EIS DMC selector switch to forbid the crew to set the EIS DMC selector switch in any position except NORM which is the valid position.
5. Close-up
Subtask 31-68-00-860-057-A
A. Aircraft Maintenance Configuration
   (1) Do the EIS Stop Procedure (Ref. AMM TASK 31-60-00-860-002)
   (2) Make an entry in the log book.
   (3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002)
[Rev.10 from 2021] 2026.04.01 00:39:04 UTC