Delete OEB REMINDER Data from FWCs using MCDUs.
TASK 31-51-00-610-002-A
Delete OEB REMINDER Data from FWCs using MCDUs.
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 31-51-00-860-053-B
Subtask 31-51-00-610-052-B
Subtask 31-51-00-860-055-B
[Rev.10 from 2021]
2026.04.01 08:41:38 UTC
Delete OEB REMINDER Data from FWCs using MCDUs.
ZONE: 210
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-51-00-610-001-A | Load OEB REMINDER Data into FWCs using MCDUs. |
| TASK 31-51-00-610-003-A | Crossload OEB REMINDER Data into FWCs using MCDUs. |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
Subtask 31-51-00-860-053-B
A. Aircraft Maintenance Configuration
Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
Subtask 31-51-00-010-051-B Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
B. Get access to the avionics compartment.
(1) Put the access platform in position below the access door 824.
(2) Open the access door 824.
Subtask 31-51-00-865-051-A (1) Put the access platform in position below the access door 824.
(2) Open the access door 824.
C. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-51-00-860-054-B 4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AUTO FLT/MCDU/1 | 11CA1 | B01 |
| ** ON A/C ALL | |||
| 49VU | FWS/FWC1/SPLY | 3WW | F01 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AUTO FLT/MCDU/1 | 11CA1 | H07 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | CFDS/CFDIU/SPLY | 2TW | J18 |
| 121VU | CFDS/CFDIU/BACK/UP | 8TW | J17 |
| ** ON A/C ALL | |||
| 121VU | AUTO FLT/MCDU/2 | 11CA2 | N20 |
| 121VU | EIS/FWC2/SPLY | 2WW | Q07 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | CFDS/CFDIU/SPLY | 2TW | J41 |
| 121VU | CFDS/CFDIU/BACK/UP | 8TW | J40 |
Subtask 31-51-00-610-052-B
A. Access to the ECAM OEB DATABASE UPDATE Menu
Subtask 31-51-00-610-053-B NOTE: The procedure below is applicable to each MCDU. The actions and results of this procedure occur on the MCDU used.
NOTE: If the response time of the FWCs is more than 1 second a IN PROGRESS message comes into view.
(1) Access to the ECAM OEB DATABASE UPDATE menu and update CODE | ACTION | RESULT |
|---|---|
| | On the MCDU: |
| 1.on one of the MCDUs, turn the OFF/BRT knob. |
|
| 2.on the MCDU, push the MCDU MENU mode key |
|
| 3.on the MCDU, push the line key to the CFDS indication. |
|
| 4.on the MCDU, push the line key adjacent to the SYSTEM REPORT/TEST indication. |
|
| 5.on the MCDU, push the line key adjacent to the INST indication. |
|
| 6.on the MCDU, push the line key adjacent to the ECAM indication. |
NOTE: For FWC1 database updating enter in the ECAM 1 menu. For FWC2 database updating enter in the ECAM 2 menu. |
| 7.on the MCDU, push the line key adjacent to the OEB DATABASE indication. |
NOTE: If the data base of the FWC1 or FWC2 is not valid, the VERSION is replaced by XXX and the check sum is replaced by XXXXX adjacent to the FWC1 or FWC2 indication. NOTE: If the opposite FWC does not respond, the NO RESPONSE message comes into view adjacent to the FWC1 or 2 indication. |
| 8.on the MCDU, with the MCDU keyboard, enter the code TWIN. NOTE: The deletion of the FWC data base is possible only if the UPDATE CODE is entered. |
|
| 9.on the MCDU, push the line key adjacent to the UPDATE CODE indication. |
NOTE: If the code not valid, the INVALID DATA message comes into view on the ECAM-1 or 2/OEB DATABASE page. |
B. Deletion of the OEB REMINDER Data from the FWC1 data by data.
Subtask 31-51-00-610-054-B NOTE: You can delete all the OEB REMINDER Data in one operation (Ref. Para. 4. C).
NOTE: You can delete the OEB REMINDER Data only if the UPDATE CODE is entered (Ref. Para. 4. A. 7.)
| ACTION | RESULT |
|---|---|
| | On the MCDU: |
| 1.on the MCDU, push the line key adjacent to the DELETE indication. |
|
| 2.on the MCDU, with the NEXT PAGE key, find the OEB data to delete and push the line key adjacent to this OEB data. |
|
| 3.on the MCDU, push the line key adjacent to the DELETE CONFIRM indication. |
NOTE: If you push the line key adjacent to the RETURN indication, the deletion is not taken into account and the previous page with the total list of OEB data comes into view. NOTE: It is imperative to enter a new VERSION reference, only when the last data has been deleted from the list. |
| 4.on the MCDU, once all modification have been inserted, with the MCDU keyboard, enter a new VERSION reference. |
NOTE: The VERSION reference must be different from the previous one. It is recommended to put the VERSION back to 000, if the FWC1 database is now empty. |
| 5.on the MCDU, push the line key adjacent to the VERSION indication. |
|
| 6.on the MCDU, push the line key adjacent to the CONFIRM indication. NOTE: The line key adjacent to the CONFIRM indication is inactive if there is no deletion or if the VERSION reference is not entered. |
NOTE: The INVALID DATA message comes into view if the deletion is faulty. (In this case it is necessary to enter again the step 6). |
NOTE: If you push the line key adjacent to the RETURN indication before you do an action on the line adjacent to the CONFIRM indication.
The UPDATE WILL BE LOST message comes into view. If a new action is done on the line key adjacent to the RETURN indication, all the modifications are lost.
The UPDATE WILL BE LOST message comes into view. If a new action is done on the line key adjacent to the RETURN indication, all the modifications are lost.
C. DELETION of all OEB REMINDER Data into the FWC1 or 2.
Subtask 31-51-00-740-051-B NOTE: You can delete the OEB REMINDER Data only if the UPDATE CODE is entered (Ref . Para. 4. A. 7.)
| ACTION | RESULT |
|---|---|
| | On the MCDU: |
| 1.on the MCDU, push the line key adjacent to the DELETE ALL indication. |
|
| 2.on the MCDU, push the line key adjacent to the DELETE CONFIRM indication. |
NOTE: If you push the line key adjacent to the RETURN indication, the deletion is not taken into account and the previous page comes into view. NOTE: It is imperative to enter a new VERSION reference (only when all modification have been inserted), it is recommended to put the VERSION back to 000, if the FWC database is now empty. |
| 3.on the MCDU, with the MCDU keyboard, enter a new VERSION reference. |
|
| 4.on the MCDU, push the line key adjacent to the VERSION indication. |
|
| 5.on the MCDU, push the line key adjacent to the CONFIRM indication. NOTE: The line key adjacent to the CONFIRM indication is inactive if there is no deletion or if the VERSION reference is not entered. |
NOTE: The INVALID DATA message comes into view if the deletion is faulty. (In this case it is necessary to enter again the step 5). |
NOTE: If you push the line key adjacent to the RETURN indication before you do an action on the line adjacent to the CONFIRM indication.
The UPDATE WILL BE LOST message comes into view. If a new action is done on the line key adjacent to the RETURN indication, all the modifications are lost.
The UPDATE WILL BE LOST message comes into view. If a new action is done on the line key adjacent to the RETURN indication, all the modifications are lost.
D. Check of the Deletion of the OEB Data With the Flight Crew Operating Manual (FCOM) "OEB Operations Engineering Bulletins" Section
(2) Do a check of the printed OEB list with the ECAM warnings and their codes given in the FCOM Preliminary Pages (List of Effective Operations Engineering Bulletin) or with the ECAM alert title (if displayed) and the Quick Reference Handbook (QRH).
(a) Make sure that the printed OEB data agrees with the data in the FCOM "OEB Operations Engineering Bulletins" section.
If the data does not agree, do the applicable procedure:
- loading (Ref. AMM TASK 31-51-00-610-001), or
- deletion (Ref: Para. 4. B. of this procedure), or.
- crossloading (Ref. AMM TASK 31-51-00-610-003).
(b) When the check list is correct, keep the OEB list in the QRH, in the cockpit.
Subtask 31-51-00-740-053-B NOTE: In case of deletion of all OEB Data, do only the Para. 4. E.
(1) Print the OEB REMINDER lists in case of deletion of some OEB DATABASE Data | ACTION | RESULT |
|---|---|
| | On the MCDU: |
| 1.on the MCDU, push the line key adjacent to the RETURN indication until the ECAM-1 or 2/OEB DATABASE page comes into view. |
|
| 2.on the MCDU, push the line key adjacent to the LIST FWC1 or LIST FWC2 indication. |
|
NOTE: In case of deletion of all OEB REMINDER list (Ref. Para. 4. E.) | |
| 3.on the MCDU, push the line key adjacent to the PRINT indication. | the first ECAM-1 or 2/OEB DATABASE/FWC1 or 2 LIST XXX page is printed. NOTE: If there is more than one page, it is necessary on the MCDU:
|
(a) Make sure that the printed OEB data agrees with the data in the FCOM "OEB Operations Engineering Bulletins" section.
If the data does not agree, do the applicable procedure:
- loading (Ref. AMM TASK 31-51-00-610-001), or
- deletion (Ref: Para. 4. B. of this procedure), or.
- crossloading (Ref. AMM TASK 31-51-00-610-003).
(b) When the check list is correct, keep the OEB list in the QRH, in the cockpit.
E. Check of the Deletion of the OEB Data With the Flight Crew Operating Manual (FCOM) or with the Quick Reference Handbook (QRH)
5. Close-upNOTE: In case of deletion of some OEB Data, do only the Para. 4. D.
(1) Print the OEB REMINDER lists in case of deletion of all OEB DATABASE Data | ACTION | RESULT |
|---|---|
| | On the MCDU: |
| 1.on the MCDU, push the line key adjacent to the RETURN indication until the ECAM-1 or 2/OEB DATABASE page comes into view. |
|
| 2.on the MCDU, push the line key adjacent to the LIST FWC1 indication. |
|
| 3.on the MCDU, push the line key adjacent to the PRINT indication. |
|
| 4.on the MCDU, push the line key adjacent to the LIST FWC2 indication. |
|
| 5.on the MCDU, push the line key adjacent to the PRINT indication. |
|
| 6.keep the OEB REMINDER list in the cockpit. | |
Subtask 31-51-00-860-055-B
A. Put the aircraft back to its initial configuration.
(1) On the MCDU, push the line key adjacent to the RETURN indication until the CFDS MENU page comes into view.
(2) Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002)
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002)
(4) Put the system back to the serviceable condition.
(5) Put the aircraft back to the serviceable condition.
(1) On the MCDU, push the line key adjacent to the RETURN indication until the CFDS MENU page comes into view.
(2) Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002)
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002)
(4) Put the system back to the serviceable condition.
(5) Put the aircraft back to the serviceable condition.