W DOC AIRBUS | AMM A320F

Ground Scanning of the Central Warning System


TASK 31-50-00-710-001-A
Ground Scanning of the Central Warning System


WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
ZONE: 210
1. Reason for the Job
Make sure that the FWC 1 and 2, the SDAC 1 and 2 and the ECP operate correctly.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-32-00-860-008-A
Procedure to Get Access to the SYSTEM REPORT/TEST/INST Page
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 34-10-00-860-002-A
ADIRS Start Procedure
TASK 34-10-00-860-005-A
ADIRS Stop Procedure
3. Job Set-up
Subtask 31-50-00-860-050-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001)
   (3) On the maintenance panel 50VU, release the ENG/FADEC GND PWR 1 & 2 pushbutton switches. The legend ON is displayed.
   (4) Do the ADIRS start procedure. (Ref. AMM TASK 34-10-00-860-002)
   (5) On one MCDU, get the SYSTEM REPORT/TEST INST menu page item. (Ref. AMM TASK 31-32-00-860-008)
Subtask 31-50-00-865-053-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUSDAC/1/SPLY3WVF04
49VUSDAC/2/26VAC SYNC/AC ESS BUS6WVF03
49VUSDAC/1/26VAC SYNC/AC ESS BUS5WVF02
49VUFWS/FWC1/SPLY3WWF01
121VUEIS/FWC2/SPLY2WWQ07
121VUEIS/SDAC/2/SPLY2WVQ06
121VUEIS/SDAC/1/BUS2/26VAC SYNC AC7WVQ03
121VUEIS/SDAC/2/BUS2/26VAC SYNC AC8WVQ02
4. Procedure
Subtask 31-50-00-710-051-B
A. Test
ACTION
RESULT
1.On one MCDU, on the INST menu page:

  • push the line key adjacent to the ECAM 1 indication.
  • the menu of the ECAM 1 page comes into view after a few seconds.
  • set the GROUND SCANNING function.
  • make sure that no failure is present by observing:
    Either a NO FAILURE message is displayed
    or no message is displayed followed by the ATA ref. 31-XX-XX
    (where X is a digit to be disregarded)
2.On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.

5. Close-up
Subtask 31-50-00-860-051-A
A. Put the aircraft back to its initial configuration.
   (1) On the ECAM control panel, set the LOWER DISPLAY and UPPER DISPLAY potentiometers to OFF.
On the maintenance panel 50VU, push the ENG/FADEC GND PWR 1 & 2 pushbutton switches, the legend ON comes OFF.
   (2) Do the ADIRS Stop Procedure (Ref. AMM TASK 34-10-00-860-005).
   (3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002)
   (4) Make sure that the work area is clean and clear of tools and other items.
[Rev.10 from 2021] 2026.04.01 08:41:43 UTC