ADIRS Stop Procedure
TASK 34-10-00-860-005-A
ADIRS Stop Procedure
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 34-10-00-860-069-A
Subtask 34-10-00-860-070-A ** ON A/C NOT FOR ALL
Subtask 34-10-00-860-071-A
[Rev.10 from 2021]
2026.04.01 04:14:31 UTC
ADIRS Stop Procedure
ZONE: 210
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 27-50-00-866-009-A | Retraction of the Flaps on the Ground |
| TASK 27-50-00-866-009-A-01 | Retraction of the Flaps/Slats on the Ground |
Subtask 34-10-00-860-069-A
A. Aircraft Maintenance Configuration
(1) Make sure that the flaps are fully retracted (Ref. AMM TASK 27-50-00-866-009).
(2) On the center pedestal, on the SWITCHING control panel 8VU:
4. Procedure(1) Make sure that the flaps are fully retracted (Ref. AMM TASK 27-50-00-866-009).
(2) On the center pedestal, on the SWITCHING control panel 8VU:
- set the AIR DATA selector switch to NORM
- set the ATT HDG selector switch to NORM.
Subtask 34-10-00-860-070-A ** ON A/C NOT FOR ALL
A. ADIRS Stop Procedure
(1) On the ADIRS CDU, pull and set the OFF/NAV/ATT selector switches to OFF.
Subtask 34-10-00-860-070-B ** ON A/C NOT FOR ALL (1) On the ADIRS CDU, pull and set the OFF/NAV/ATT selector switches to OFF.
A. ADIRS Stop Procedure
(1) On ADIRS MSU panel 41VU, pull and set the OFF/NAV/ATT selector switches to OFF.
5. Close-up(1) On ADIRS MSU panel 41VU, pull and set the OFF/NAV/ATT selector switches to OFF.
Subtask 34-10-00-860-071-A
A. Put the aircraft back to its initial configuration.
(1) On the panels 301VU and 500VU, set the PFD and ND potentiometers to OFF.
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) On the panels 301VU and 500VU, set the PFD and ND potentiometers to OFF.
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).