W DOC AIRBUS | AMM A320F

Operational Test of DFDR


TASK 31-39-00-710-809-A
Operational Test of DFDR


FIN: 1TU ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-32-00-860-008-A
Procedure to Get Access to the SYSTEM REPORT/TEST/INST Page
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
3. Job Set-up
Subtask 31-39-00-710-062-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
   (2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001)
   (3) Energize the CFDS (Ref. AMM TASK 31-32-00-860-008)
Subtask 31-39-00-865-063-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VURCDR/DFDR7TUK16
** ON A/C NOT FOR ALL
121VURCDR/ACCLRM9TUK18
121VUAIDS & RCDR/FDIMU5TVK15
** ON A/C NOT FOR ALL
121VURCDR2 CVR&FDR42TUK16
** ON A/C NOT FOR ALL
121VURCDR/ACCLRM9TUK41
121VURCDR2 CVR&FDR42TUK39
121VUAIDS & RCDR/FDIMU5TVK38
4. Procedure
Subtask 31-39-00-710-063-A ** ON A/C NOT FOR ALL
A. Operational test of the DFDR
ACTION
RESULT
1.On control panel 21VU:
On control panel 21VU:
  • Press the GND/CTL button.
  • The blue indicator light "ON" comes on.
2.On panel 121VU:
On the ECAM display:
  • Open circuit breaker DFDR 7TU (K16).
  • The "RECORDER DFDR FAULT" indication comes on.
  • Close circuit breaker DFDR 7TU (K16).
  • The "RECORDER DFDR FAULT" indication goes off.
3.On control panel 21VU:
On control panel 21VU:
  • Press the GND/CTL button.
  • The blue indicator light "ON" goes off.
5. Close-up
Subtask 31-39-00-710-064-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Put the aircraft back to its initial configuration.
   (2) De-energize the CFDS
(Ref. AMM TASK 31-32-00-860-008)
   (3) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002)
   (4) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002)
[Rev.10 from 2021] 2026.04.01 08:31:32 UTC