Reactivation of the Window Heat Computer (WHC)
TASK 30-42-00-440-001-A
Reactivation of the Window Heat Computer (WHC)
1. Reason for the Job
MMEL 30-42-01A
WINDOW HEAT COMPUTER
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 30-42-00-861-053-A Subtask 30-42-00-869-062-A
Subtask 30-42-00-865-058-A
Subtask 30-42-00-869-063-A Subtask 30-42-00-862-053-A
[Rev.10 from 2021]
2026.04.01 00:30:54 UTC
Reactivation of the Window Heat Computer (WHC)
1. Reason for the Job
MMEL 30-42-01A
WINDOW HEAT COMPUTER
- To do the trouble shooting of the deactivated WHC.
- To do a check of the two WHCs for correct operation.
- To put the two WHCs in the normal configuration.
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
Subtask 30-42-00-861-053-A Subtask 30-42-00-869-062-A
B. Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
4. Procedure(Ref. AMM TASK 31-60-00-860-001).
Subtask 30-42-00-865-058-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 30-42-00-210-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 2DG1 (WHC1) | |||
| 122VU | ANTI ICE/WINDOWS/L | 4DG1 | X14 |
| 122VU | ANTI ICE/WHC/1 | 5DG1 | X13 |
| 123VU | ANTI ICE/L/WHSLD | 1DG1 | AF10 |
| FOR FIN: 2DG2 (WHC2) | |||
| 122VU | ANTI ICE/WINDOWS/R | 4DG2 | W14 |
| 122VU | ANTI ICE/WHC/2 | 5DG2 | W13 |
| 123VU | ANTI ICE/R/WHSLD | 1DG2 | AF03 |
B. Check of the Warning Messages of the Fixed and Sliding Windows
(1) On the Upper ECAM DU make sure that the warning messages:
Subtask 30-42-00-865-059-A (1) On the Upper ECAM DU make sure that the warning messages:
- A.ICE L WSHLD HEAT
- A.ICE R WSHLD HEAT
- A.ICE L WINDOW HEAT
- A.ICE R WINDOW HEAT
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 2DG1 (WHC1) | |||
| 122VU | ANTI ICE/WINDOWS/L | 4DG1 | X14 |
| 122VU | ANTI ICE/WHC/1 | 5DG1 | X13 |
| 123VU | ANTI ICE/L/WHSLD | 1DG1 | AF10 |
| FOR FIN: 2DG2 (WHC2) | |||
| 122VU | ANTI ICE/WINDOWS/R | 4DG2 | W14 |
| 122VU | ANTI ICE/WHC/2 | 5DG2 | W13 |
| 123VU | ANTI ICE/R/WHSLD | 1DG2 | AF03 |
Subtask 30-42-00-869-063-A Subtask 30-42-00-862-053-A