W DOC AIRBUS | AMM A320F

Detailed Inspection of the Anti-Ice Pylon Duct


TASK 30-21-49-290-801-A
Detailed Inspection of the Anti-Ice Pylon Duct


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
1
BORESCOPE DIA 6 MM (0.2 IN.) MAX - SIDE VIEW FLEXIBLE
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 55 and 45 lbf.in (0.62 and 0.51 m.daN ) T
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 30-21-49-000-042-A
Removal of the Pylon Anti-ice Duct
TASK 30-21-49-400-042-A
Installation of the Pylon Anti-ice Duct
TASK 30-21-49-820-001-A
Rig the Anti-ice Ducts
TASK 70-23-11-911-013-A
General Torque Tightening Techniques
TASK 71-00-20-000-040-A
Removal of the Power Plant
TASK 71-00-20-000-040-A-01
Removal of the Power Plant with the Engine Positioner TWW 75E (MIAG)
TASK 71-00-20-400-040-A
Installation of the Power Plant
TASK 71-00-20-400-040-A-01
Installation of the Power Plant with the Engine Positioner TWW 75E (MIAG)
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
TASK 78-30-00-440-012-A
Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance
TASK 78-32-00-010-010-A
Opening of the Thrust Reverser Halves
TASK 78-32-00-410-010-A
Closing of the Thrust Reverser Halves
3. Job Set-up
Subtask 30-21-49-861-072-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 30-21-49-941-107-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 30-21-49-865-105-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 1000EM1 (ENGINE1)
122VUANTI ICE/ENG/11DN1X10
FOR FIN: 1000EM2 (ENGINE2)
122VUANTI ICE/ENG/21DN2W10
Subtask 30-21-49-010-145-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
Subtask 30-21-49-040-088-A ** ON A/C NOT FOR ALL
E. Deactivate the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Deactivate the thrust reverser Hydraulic Control Unit (HCU) (Ref. AMM TASK 78-30-00-040-012).
Subtask 30-21-49-010-146-A ** ON A/C NOT FOR ALL
F. Open the thrust reverser halves (Ref. AMM TASK 78-32-00-010-010):
   (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
   (2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure
Subtask 30-21-49-290-050-A ** ON A/C NOT FOR ALL
A. Detailed Inspection of the Pylon Anti-Ice Duct
   (1) Do a hole or a crack detection through the inspection of the pylon anti-ice duct:
     (a) Remove the coupling (3).
     (b) Put the BORESCOPE DIA 6 MM (0.2 IN.) MAX - SIDE VIEW FLEXIBLE or an equivalent in the pylon anti-ice duct.
     (c) Examine the duct along its full length:
NOTE: You can refer to the Duct and Fuel Pipe Repair Manual (DFPRM) to find the allowable damage limits and the repair solutions for your duct part number.
NOTE: The allowable damage limits and the repair solutions for ducts No. 1, 2, 3, 4 and 5 are not given in the DFPRM.
       1 If there is a hole or a crack, replace the pylon anti-ice duct (Ref. AMM TASK 30-21-49-000-042) and (Ref. AMM TASK 30-21-49-400-042).
If the parts must be replaced, remove and install the engine (Ref. AMM TASK 71-00-20-000-040) and (Ref. AMM TASK 71-00-20-400-040).
       2 If there is no hole or a crack:
         a Install the coupling (3).
         b TORQUE the coupling nut (3) to between 55 and 45 lbf.in (0.62 and 0.51 m.daN ) T (Ref. AMM TASK 70-23-11-911-013).
         c Do the rigging of the anti-ice ducts (Ref. AMM TASK 30-21-49-820-001).
5. Close-up
Subtask 30-21-49-410-119-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 30-21-49-440-072-A ** ON A/C NOT FOR ALL
B. Activate the thrust reverser HCU (Ref. AMM TASK 78-30-00-440-012).
Subtask 30-21-49-410-120-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
Subtask 30-21-49-865-106-A ** ON A/C NOT FOR ALL
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 1000EM1 (ENGINE1)
122VUANTI ICE/ENG/11DN1X10
FOR FIN: 1000EM2 (ENGINE2)
122VUANTI ICE/ENG/21DN2W10
Subtask 30-21-49-862-069-A ** ON A/C NOT FOR ALL
E. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.01 00:30:11 UTC