Installation of the Pylon Anti-ice Duct


TASK 30-21-49-400-042-A
Installation of the Pylon Anti-ice Duct


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M(3 FT)
No specific
AR
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.V01-002)
cleaning fluid
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
11
SEAL
EIPC 36-11-06-02-060
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 71-00-20-000-040-A
Removal of the Power Plant
TASK 71-00-20-000-040-A-01
Removal of the Power Plant with the Engine Positioner TWW 75E (MIAG)
TASK 71-00-20-400-040-A
Installation of the Power Plant
TASK 71-00-20-400-040-A-01
Installation of the Power Plant with the Engine Positioner TWW 75E (MIAG)
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
TASK 78-30-00-440-012-A
Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance
TASK 78-32-00-010-010-A
Opening of the Thrust Reverser Halves
TASK 78-32-00-410-010-A
Closing of the Thrust Reverser Halves
3. Job Set-up
Subtask 30-21-49-941-102-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001)
   (2) On the center pedestal, on the ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than 5 minutes before you do this procedure.
     (c) Make sure that the WARNING NOTICE(S) to tell persons not to operate:
  • the ENG/MODE selector switch
  • the ENG/MASTER 1(2) control switch
    is in position.
   (3) On the ENG section of the maintenance panel 50VU:
     (a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Make sure that the WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2), is in position.
Subtask 30-21-49-865-103-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUANTI ICE/ENG/21DN2W10
122VUANTI ICE/ENG/11DN1X10
Subtask 30-21-49-010-143-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR.
   (2) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
Subtask 30-21-49-040-087-A ** ON A/C NOT FOR ALL
D. Make sure that the thrust reverser Hydraulic Control Unit (HCU) is deactivated (Ref. AMM TASK 78-30-00-040-012).
Subtask 30-21-49-010-144-A ** ON A/C NOT FOR ALL
E. Get Access
   (1) Make sure that the thrust reverser cowl-doors are open (Ref. AMM TASK 78-32-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
451AL, 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL, 462AR.
Subtask 30-21-49-860-061-A ** ON A/C NOT FOR ALL
F. Make sure that the power plant is lowered (Ref. AMM TASK 71-00-20-000-040).
4. Procedure
Subtask 30-21-49-110-064-A ** ON A/C NOT FOR ALL
A. Clean the Ends of the Ducts
   (1) Use a Textile-Lint free Cotton - (Material No.14SBA1) made moist with cleaning fluid (Material No.V01-002) to clean the ends of the ducts.
Subtask 30-21-49-420-063-C ** ON A/C NOT FOR ALL
B. Installation of the Pylon Anti-Ice Duct
F Pylon Anti-ice Duct ** ON A/C NOT FOR ALL
CAUTION: MAKE SURE THAT THE SEGMENTS ARE CORRECTLY INSTALLED IN THE HOUSING.
   (1) Install the pylon anti-ice duct (1).
   (2) Install the stop plate (4) with the four screws (5) on the support.
   (3) Make sure that the segments (3) are correctly installed in the housing (2).
Subtask 30-21-49-420-098-A ** ON A/C NOT FOR ALL 5. Close-up
Subtask 30-21-49-410-081-A ** ON A/C NOT FOR ALL
Subtask 30-21-49-865-104-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUANTI ICE/ENG/21DN2W10
122VUANTI ICE/ENG/11DN1X10
Subtask 30-21-49-410-117-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 30-21-49-440-071-A ** ON A/C NOT FOR ALL
D. Activate the thrust reverser HCU (Ref. AMM TASK 78-30-00-440-012).
Subtask 30-21-49-410-118-A ** ON A/C NOT FOR ALL
E. Close Access
   (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Remove the WARNING NOTICE(S).
   (3) Remove the access platform(s).
Subtask 30-21-49-862-068-A ** ON A/C NOT FOR ALL
F. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001)