W DOC AIRBUS | AMM A320F

Removal of the Pylon Anti-ice Duct


TASK 30-21-49-000-042-A
Removal of the Pylon Anti-ice Duct


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M(3 FT)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 71-00-20-000-040-A
Removal of the Power Plant
TASK 71-00-20-000-040-A-01
Removal of the Power Plant with the Engine Positioner TWW 75E (MIAG)
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
TASK 78-32-00-010-010-A
Opening of the Thrust Reverser Halves
3. Job Set-up
Subtask 30-21-49-861-071-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 30-21-49-941-101-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than 5 minutes before you do this procedure.
     (c) Put a WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
   (2) On the ENG section of the maintenance panel 50VU:
     (a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
Subtask 30-21-49-865-102-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUANTI ICE/ENG/21DN2W10
122VUANTI ICE/ENG/11DN1X10
Subtask 30-21-49-010-141-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Put an ACCESS PLATFORM 1M(3 FT) in position.
Subtask 30-21-49-040-086-A ** ON A/C NOT FOR ALL
E. Deactivation of the Thrust Reverser for Maintenance
WARNING: MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Do the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-012).
Subtask 30-21-49-010-142-A ** ON A/C NOT FOR ALL
F. Get Access
   (1) Open the thrust reverser cowl-doors (Ref. AMM TASK 78-32-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 30-21-49-010-093-A ** ON A/C NOT FOR ALL
G. Lower the Power Plant (Ref. AMM TASK 71-00-20-000-040).
NOTE: Lower the engine between 0.3 m (1 ft.) and 0.4 m (1.3 ft.).
4. Procedure
Subtask 30-21-49-020-094-A ** ON A/C NOT FOR ALL
A. Removal of the Starter Elbow-Duct
F Starter Elbow-Duct ** ON A/C NOT FOR ALL
   (1) Remove the clamps (9) and (12) to disengage the duct (10).
     (a) Remove the four bolts (14) and the four washers (15) from the skin/junction panel (13).
     (b) Remove the four bolts (16) from the skin/junction panel (13).
   (2) Remove the duct.
     (a) Remove the bolt (17), the four bolts (14) and the four washers (15) from the pylon support and sliding bracket (8).
     (b) Remove the duct (10).
     (c) Remove and discard the seal (11).
     (d) Remove the sliding bracket (8) from the duct (10).
   (3) Remove the skin/junction panel (13).
Subtask 30-21-49-020-066-C ** ON A/C NOT FOR ALL
B. Removal of the Pylon Anti-Ice Duct
F Pylon Anti-ice Duct ** ON A/C NOT FOR ALL
   (1) Remove the four screws (5) and the stop plate (4) from the support.
     (a) Remove the pylon anti-ice duct (1).
[Rev.10 from 2021] 2026.04.01 00:29:40 UTC