W DOC AIRBUS | AMM A320F

Operational Test of the FCDC


TASK 27-96-00-710-001-A
Operational Test of the FCDC


ZONE: 210
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
3. Job Set-up
Subtask 27-96-00-860-058-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
   (2) On the overhead panel 23VU, make sure that:
  • The FLT CTL/ELAC 1 and FLT CTL/SEC 1 pushbutton switches are pushed (on these pushbutton switches, the FAULT and OFF legends are off).
   (3) On the overhead panel 24VU, make sure that:
  • The FLT CTL/ELAC 2, FLT CTL/SEC 2 and FLT CTL/SEC 3 pushbutton switches are pushed (on these pushbutton switches, the FAULT and OFF legends are off).
   (4) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
Subtask 27-96-00-865-055-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/ELAC1/NORM/SPLY15CE1B11
49VUFLIGHT CONTROLS/FCDC1/SPLY20CE1B10
49VUFLIGHT CONTROLS/SEC1/NORM/SPLY21CE1B08
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/ELAC1/NORM/SPLY15CE1B06
49VUFLIGHT CONTROLS/FCDC1/SPLY20CE1B05
49VUFLIGHT CONTROLS/SEC1/NORM/SPLY21CE1B03
** ON A/C NOT FOR ALL
121VUPTR/SPLY6TWJ21
121VUCFDS/CFDIU/SPLY2TWJ18
121VUCFDS/CFDIU/BACK/UP8TWJ17
** ON A/C ALL
121VUFLIGHT CONTROLS/FCDC2/SPLY20CE2Q20
121VUFLIGHT CONTROLS/SEC3/SPLY21CE3Q19
121VUFLIGHT CONTROLS/SEC2/SPLY21CE2Q18
121VUFLIGHT CONTROLS/ELAC2/NORM/SPLY15CE2R20
** ON A/C NOT FOR ALL
121VUPTR/SPLY6TWJ44
121VUCFDS/CFDIU/SPLY2TWJ41
121VUCFDS/CFDIU/BACK/UP8TWJ40
4. Procedure
Subtask 27-96-00-710-055-A
A. Do this test:
ACTION
RESULT
1.On the circuit breaker panel 121VU:
- Open the C/B 20CE2.
On the upper ECAM display unit:
- The F/CTL FCDC2 FAULT message is shown.
2.On the center pedestal, on the ECAM control panel:
- Push the F/CTL key.
On the lower ECAM display unit, the F/CTL page comes into view.
Make sure that:
- There are no crosses on the EFCS servocontrols.
On the upper ECAM display unit, make sure that:
- No F/CTL FCDC1 FAULT message is shown.
3.On the circuit breaker panel 121VU:
- Close the C/B 20CE2.
On the upper ECAM display unit:
- The F/CTL FCDC2 FAULT message goes out of view.
4.On the circuit breaker panel 49VU:
- Open the C/B 20CE1.
On the upper ECAM display unit:
- The F/CTL FCDC1 FAULT message is shown.
- Make sure that no F/CTL FCDC2 FAULT message is shown.
On the lower ECAM display unit, on the F/CTL page:
- Make sure that there are no crosses on the EFCS servocontrols.
5.On the circuit breaker panel 49VU:
- Close the C/B 20CE1.
On the upper ECAM display unit:
- The F/CTL FCDC1 FAULT message goes out of view.
5. Close-up
Subtask 27-96-00-860-059-A
A. Put the aircraft back to its initial configuration.
   (1) Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).
   (2) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 07:14:35 UTC