Operational Check of Engine-Bottle Low-Pressure Indicating-Circuit
TASK 26-21-00-710-002-A
Operational Check of Engine-Bottle Low-Pressure Indicating-Circuit
Refer to the MPD TASK: 262100-02
OPERATIONAL CHECK OF BOTTLE LOW PRESSURE INDICATING CIRCUIT
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 26-21-00-861-053-A
Subtask 26-21-00-710-054-A ** ON A/C NOT FOR ALL
Subtask 26-21-00-710-069-A ** ON A/C NOT FOR ALL
5. Close-up
Subtask 26-21-00-410-055-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 04:26:59 UTC
Operational Check of Engine-Bottle Low-Pressure Indicating-Circuit
ZONE: 210
1. Reason for the JobRefer to the MPD TASK: 262100-02
OPERATIONAL CHECK OF BOTTLE LOW PRESSURE INDICATING CIRCUIT
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | ALLEN KEY 3/32 IN |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| FOR [1000EM1] (ENGINE-1) | |
| 415BL, 415BR | |
| FOR [1000EM2] (ENGINE-2) | |
| 425BL, 425BR | |
| FOR [6WE1] (BOTTLE 1-FIRE EXTING, ENG 1) | |
| 415BL | |
| FOR [6WE2] (BOTTLE 1-FIRE EXTING, ENG 2) | |
| 425BL | |
| FOR [8WE1] (BOTTLE 2-FIRE EXTING, ENG 1) | |
| 415CR | |
| FOR [8WE2] (BOTTLE 2-FIRE EXTING, ENG 2) | |
| 425CR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 54-51-21-000-802-A | Removal of the Pylon Lateral Access-Doors |
| TASK 54-51-21-400-802-A | Installation of the Pylon Lateral Access-Doors |
Subtask 26-21-00-861-053-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 26-21-00-941-060-A (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
B. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Make sure that the ENG/MODE/CRANK/NORM/IGN/START selector switch is in the NORM position.
(b) Put a WARNING NOTICE(S) in position to tell persons not to operate ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the ENG section of maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 26-21-00-865-071-A (1) On the center pedestal, on the ENG panel 115VU:
(a) Make sure that the ENG/MODE/CRANK/NORM/IGN/START selector switch is in the NORM position.
(b) Put a WARNING NOTICE(S) in position to tell persons not to operate ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the ENG section of maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
C. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 26-21-00-010-055-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | ENGINE/2/FIRE DET/LOOP B | 8WD2 | A07 |
| 49VU | ENGINE/1/FIRE DET/LOOP A | 7WD1 | A06 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B | 2WE1 | Q44 |
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B | 2WE2 | Q42 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/A | 1WE1 | Q43 |
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A | 1WE2 | Q41 |
| ** ON A/C ALL | |||
| 121VU | ENGINE/ENG2/FIRE DET/LOOP A | 7WD2 | Q39 |
| 121VU | ENGINE/ENG1/FIRE DET/LOOP B | 8WD1 | Q38 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B | 2WE1 | Q44 |
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B | 2WE2 | Q42 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B | 2WE1 | Q43 |
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/A | 1WE1 | Q42 |
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B | 2WE2 | Q41 |
| 121VU | ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A | 1WE2 | Q40 |
D. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the engine.
(2) Remove these access panels:
(a) FOR [1000EM1] (ENGINE-1)
415BL 415BR
(b) FOR [1000EM2] (ENGINE-2)
425BL 425BR
Subtask 26-21-00-010-055-B ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the engine.
(2) Remove these access panels:
(a) FOR [1000EM1] (ENGINE-1)
415BL 415BR
(b) FOR [1000EM2] (ENGINE-2)
425BL 425BR
D. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the pylon.
(2) Remove the following access doors (Ref. AMM TASK 54-51-21-000-802):
(3) FOR [6WE1] (BOTTLE 1-FIRE EXTING, ENG 1)
(4) FOR [8WE1] (BOTTLE 2-FIRE EXTING, ENG 1)
(5) FOR [6WE2] (BOTTLE 1-FIRE EXTING, ENG 2)
(6) FOR [8WE2] (BOTTLE 2-FIRE EXTING, ENG 2)
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the pylon.
(2) Remove the following access doors (Ref. AMM TASK 54-51-21-000-802):
(3) FOR [6WE1] (BOTTLE 1-FIRE EXTING, ENG 1)
(4) FOR [8WE1] (BOTTLE 2-FIRE EXTING, ENG 1)
(5) FOR [6WE2] (BOTTLE 1-FIRE EXTING, ENG 2)
(6) FOR [8WE2] (BOTTLE 2-FIRE EXTING, ENG 2)
Subtask 26-21-00-710-054-A ** ON A/C NOT FOR ALL
A. Operational Test of the Engine Fire-Extinguisher Bottles Low-Pressure (for P/N 86181007)
Subtask 26-21-00-710-054-B ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
| 1.In the left (right) engine pylon, on the fire-extinguisher bottle 6WE1 (6WE2): | On the ENG/APU FIRE panel 1WD (overhead panel 20VU): |
| A.Push the pressure contact pushbutton switch. |
|
| B.Release the pressure contact pushbutton switch. |
|
| 2.In the left (right) engine pylon, on the fire-extinguisher bottle 8WE1 (8WE2): | On the ENG/APU FIRE panel 1WD: |
| A.Push the pressure contact pushbutton switch. |
|
| B.Release the pressure contact pushbutton switch. |
|
CAUTION:
TO DO THE MANUAL PRESSURE TEST OF THE ENGINE-FIRE EXTINGUISHER BOTTLE, TURN THE ALLEN KEY CLOCKWISE UNTIL YOU FEEL A FORCE (AT APPROXIMATELY 10 DEGREES). DO NOT TURN THE ALLEN KEY MORE THAN NECESSARY TO PREVENT DAMAGE TO THE PRESSURE SWITCH.
A. Operational Test of the Engine Fire-Extinguisher Bottles Low-Pressure | ACTION | RESULT |
|---|---|
| 1.In the left (right) engine pylon, on the fire-extinguisher bottle 6WE1 (6WE2): | On the ENG/APU FIRE panel 1WD (overhead panel 20VU): |
| A.Engage the ALLEN KEY 3/32 IN and turn it clockwise (approximately 10 degrees) until you can feel a force. |
|
| B.Release the Allen wrench to let the test point go back by itself to its initial position. |
|
| 2.In the left (right) engine pylon, on the fire-extinguisher bottle 8WE1 (8WE2): | On the ENG/APU FIRE panel 1WD (overhead panel 20VU): |
| A.Engage the allen wrench (3/32 in. hex key); turn the Allen wrench clockwise (by 10 degrees approximately) until you can feel a force. |
|
| B.Release the Allen wrench to let the test point go back by itself to its initial position. |
|
CAUTION:
TO DO THE MANUAL PRESSURE TEST OF THE ENGINE-FIRE EXTINGUISHER BOTTLE, TURN THE ALLEN KEY CLOCKWISE UNTIL YOU FEEL A FORCE (AT APPROXIMATELY 10 DEGREES). DO NOT TURN THE ALLEN KEY MORE THAN NECESSARY TO PREVENT DAMAGE TO THE PRESSURE SWITCH.
B. Operational Test of the Engine Fire-Extinguisher Bottles Low-Pressure (for P/N 34100005-1 and P/N 472088-series) | ACTION | RESULT |
|---|---|
| 1.In the left (right) engine pylon, on the fire-extinguisher bottle 6WE1 (6WE2): | On the ENG/APU FIRE panel 1WD (overhead panel 20VU): |
| A.Engage the ALLEN KEY 3/32 IN and turn it clockwise (approximately 10 degrees) until you can feel a force. |
|
| B.Release the Allen wrench to let the test point go back by itself to its initial position. |
|
| 2.In the left (right) engine pylon, on the fire-extinguisher bottle 8WE1 (8WE2): | On the ENG/APU FIRE panel 1WD (overhead panel 20VU): |
| A.Engage the allen wrench (3/32 in. hex key); turn the Allen wrench clockwise (by 10 degrees approximately) until you can feel a force. |
|
| B.Release the Allen wrench to let the test point go back by itself to its initial position. |
|
Subtask 26-21-00-410-055-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install these access panels:
(a) FOR [1000EM1] (ENGINE-1)
415BL 415BR.
(b) FOR [1000EM2] (ENGINE-2)
425BL 425BR.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 26-21-00-410-055-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install these access panels:
(a) FOR [1000EM1] (ENGINE-1)
415BL 415BR.
(b) FOR [1000EM2] (ENGINE-2)
425BL 425BR.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install these access doors (Ref. AMM TASK 54-51-21-400-802):
(3) FOR [6WE1] (BOTTLE 1-FIRE EXTING, ENG 1)
(4) FOR [8WE1] (BOTTLE 2-FIRE EXTING, ENG 1)
(5) FOR [6WE2] (BOTTLE 1-FIRE EXTING, ENG 2)
(6) FOR [8WE2] (BOTTLE 2-FIRE EXTING, ENG 2)
(7) Remove all the fixtures, tools, test and support equipment used during this procedure.
(8) Remove the access platform(s).
(9) Remove the WARNING NOTICE(S).
Subtask 26-21-00-862-053-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install these access doors (Ref. AMM TASK 54-51-21-400-802):
(3) FOR [6WE1] (BOTTLE 1-FIRE EXTING, ENG 1)
(4) FOR [8WE1] (BOTTLE 2-FIRE EXTING, ENG 1)
(5) FOR [6WE2] (BOTTLE 1-FIRE EXTING, ENG 2)
(6) FOR [8WE2] (BOTTLE 2-FIRE EXTING, ENG 2)
(7) Remove all the fixtures, tools, test and support equipment used during this procedure.
(8) Remove the access platform(s).
(9) Remove the WARNING NOTICE(S).
B. Put the aircraft back to its initial configuration.
(1) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
(1) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
Test of the Engine Fire-Extinguisher Bottle Low Pressure