Detailed Inspection of G, E and P Routes in the Forward Avionic Compartment (EWIS)
TASK 24-92-00-220-005-A
Detailed Inspection of G, E and P Routes in the Forward Avionic Compartment (EWIS)
1. Reason for the Job
Refer to the MPD TASK: 200121-04
DETAILED INSPECTION OF G, E AND P ROUTES IN THE FORWARD AVIONIC COMPARTMENT (EWIS)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-92-00-010-091-A
Subtask 24-92-00-220-055-A
Subtask 24-92-00-410-089-A
[Rev.10 from 2021]
2026.03.31 23:26:09 UTC
Detailed Inspection of G, E and P Routes in the Forward Avionic Compartment (EWIS)
1. Reason for the Job
Refer to the MPD TASK: 200121-04
DETAILED INSPECTION OF G, E AND P ROUTES IN THE FORWARD AVIONIC COMPARTMENT (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | FLASHLIGHT |
| No specific | AR | MIRROR - INSPECTION, FLEXIBLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121 | AVIONICS COMPARTMENT |
| 122 | AVIONICS COMPARTMENT |
| 121AF, 121AL, 121BF, 121CF, 122BF, 811 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
| TASK 53-12-13-000-001-A | Removal of the avionics compartment floor panels |
| TASK 53-12-13-400-001-A | Installation of the avionics compartment floor panels |
| ESPM 2052120 | |
| AWM 942106 | |
| AWM 942120 | |
| AWM 942305 | |
Subtask 24-92-00-010-091-A
A. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(2) Open the access doors:
(3) Remove the forward avionic-compartment floor-panels 121AF 121BF 121CF 122BF (Ref. AMM TASK 53-12-13-000-001).
Subtask 24-92-00-862-079-A (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(2) Open the access doors:
(3) Remove the forward avionic-compartment floor-panels 121AF 121BF 121CF 122BF (Ref. AMM TASK 53-12-13-000-001).
B. Make sure that the aircraft electrical circuits are de-energized
(Ref. AMM TASK 24-41-00-862-002).
4. Procedure(Ref. AMM TASK 24-41-00-862-002).
Subtask 24-92-00-220-055-A
A. Detailed Inspection of G, E and P Route Wiring in the Forward Avionic Compartment
(1) Do a detailed inspection of the wiring to make sure that there is no signs of ageing, alteration, overheating, scaling and deformation ESPM 2052120:
(a) On the AC/DC feeder routes: 4G, 5G and 6G AWM 942106.
(b) On the AC/DC power-distribution routes: 1P, 2P and 6P AWM 942305, AWM 942106 and AWM 942120.
(c) On the generator excitation routes: 1E, 2E and 3E AWM 942305 and AWM 942120.
5. Close-up(1) Do a detailed inspection of the wiring to make sure that there is no signs of ageing, alteration, overheating, scaling and deformation ESPM 2052120:
(a) On the AC/DC feeder routes: 4G, 5G and 6G AWM 942106.
(b) On the AC/DC power-distribution routes: 1P, 2P and 6P AWM 942305, AWM 942106 and AWM 942120.
(c) On the generator excitation routes: 1E, 2E and 3E AWM 942305 and AWM 942120.
NOTE: Use a FLASHLIGHT or a MIRROR - INSPECTION, FLEXIBLE if necessary.
(2) Make sure that there is no dust, lint or hydraulic contamination. Subtask 24-92-00-410-089-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the forward avionics-compartment floor-panels 121AF 121BF 121CF 122BF (Ref. AMM TASK 53-12-13-400-001).
(3) Close the access doors:
(4) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the forward avionics-compartment floor-panels 121AF 121BF 121CF 122BF (Ref. AMM TASK 53-12-13-400-001).
(3) Close the access doors:
(4) Remove the access platform(s).
Forward Avionic Compartment - Access