1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
PLUG - BLANKING
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
120
AVIONICS COMPARTMENT
811, 824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 25-71-00-000-801-A
Removal of the Umbrella Assembly
3. Job Set-up
Subtask 53-12-13-941-051-A
A. Safety Precautions
   (1) On the AIR COND panel 30VU:
     (a) Make sure that the APU BLEED, all ENG BLEED and the PACK 1(2) pushbutton switches are released.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to operate these pushbutton switches.
   (2) On the HP and LP ground connectors, put a WARNING NOTICE(S) in position to tell persons not to supply the ground air sources.
Subtask 53-12-13-010-050-A
B. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position in the zones 121/122 and 128.
   (2) Open access doors 811 and 824.
   (3) If applicable, remove the umbrella assembly (Ref. AMM TASK 25-71-00-000-801).
4. Procedure
Subtask 53-12-13-020-050-A
A. Removal of the FWD Avionics-Compartment Floor-Panels
   (1) Remove the screws (1).
   (2) Remove the screws (3) and the nuts (7).
   (3) Remove the stiffener (2).
   (4) Remove the screws (5).
   (5) Remove the panels (4), (8), (9) and (10).
   (6) Make sure that the clipnuts (6) are installed on the structure (11).
Subtask 53-12-13-020-051-B
B. Removal of the AFT Avionics-Compartment Floor-Panels
   (1) Remove the screws (28) and the washers (29).
   (2) Remove the sheet metal assembly (30).
   (3) Remove the screws (25) and the washers (26).
   (4) Remove the track (27).
   (5) Remove the screws (22) and the washers (23).
   (6) Remove the fitting (24).
   (7) Disconnect the air-conditioning ventilation duct from the panel (20).
   (8) Put the PLUG-BLANKING in each disconnected line end.
   (9) Remove the screws (11).
   (10) Remove the panel (12).
   (11) Remove the screws (19) and the washers (18).
   (12) Remove the panels (20) and (21).
   (13) Remove the screws (13).
   (14) Remove the panels (14), (15), (16) and (17).