General Visual Inspection of G Route(s) Installed Around FR47.1 (EWIS)
TASK 24-92-00-210-031-C
General Visual Inspection of G Route(s) Installed Around FR47.1 (EWIS)
1. Reason for the Job
Refer to the MPD TASK: 200241-03
GENERAL VISUAL INSPECTION OF G ROUTES INSTALLED AROUND FR 47/48 (A320)/FR 47.1 (A321)/FR 47/51 (A319)/FR 47/54 (A318) (EWIS)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-92-00-010-173-A ** ON A/C NOT FOR ALL
Subtask 24-92-00-210-121-A ** ON A/C NOT FOR ALL
Subtask 24-92-00-410-176-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:26:15 UTC
General Visual Inspection of G Route(s) Installed Around FR47.1 (EWIS)
1. Reason for the Job
Refer to the MPD TASK: 200241-03
GENERAL VISUAL INSPECTION OF G ROUTES INSTALLED AROUND FR 47/48 (A320)/FR 47.1 (A321)/FR 47/51 (A319)/FR 47/54 (A318) (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | FLASHLIGHT |
| No specific | AR | MIRROR - INSPECTION, FLEXIBLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 251 | AFT PASSENGER COMPARTMENT |
| 252 | AFT PASSENGER COMPARTMENT |
| 251CW, 252AW, 252BW, 252CW |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 25-23-43-000-001-A | Removal of the Upper Sidewall Panel |
| TASK 25-23-43-400-001-A | Installation of the Upper Sidewall Panel |
| TASK 25-23-44-000-001-A | Removal of the Lower Sidewall Panels (Dado Panels) |
| TASK 25-23-44-400-001-A | Installation of the Lower Sidewall Panels (Dado Panels) |
| TASK 25-23-48-000-001-A | Removal of the Cove Light Panel |
| TASK 25-23-48-400-001-A | Installation of the Cove Light Panel |
| TASK 25-42-41-000-001-A | Removal of Lavatory H |
| TASK 25-42-41-400-001-A | Installation of Lavatory H |
| TASK 52-10-00-010-001-A | Opening of the Passenger/Crew Door |
| TASK 52-10-00-410-001-A | Closing of the Passenger/Crew Door |
| ESPM 2052110 | |
Subtask 24-92-00-010-173-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position in zone 832 (842).
(2) Open passenger/crew door 832 (842) (Ref. AMM TASK 52-10-00-010-001).
(3) Remove the furnishings in zone 250 between FR47 and FR47.2.
(a) Remove the lavatories, if installed (Ref. AMM TASK 25-42-41-000-001).
(4) Remove the lining in zone 250 between FR47 and FR47.2.
(a) Remove upper sidewall panel 252BW (Ref. AMM TASK 25-23-43-000-001).
(b) Remove lower sidewall panel 252AW (Ref. AMM TASK 25-23-44-000-001).
(c) Remove the cove light panel 251CW, and 252CW (Ref. AMM TASK 25-23-48-000-001).
Subtask 24-92-00-862-155-A ** ON A/C NOT FOR ALL (1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position in zone 832 (842).
(2) Open passenger/crew door 832 (842) (Ref. AMM TASK 52-10-00-010-001).
(3) Remove the furnishings in zone 250 between FR47 and FR47.2.
(a) Remove the lavatories, if installed (Ref. AMM TASK 25-42-41-000-001).
(4) Remove the lining in zone 250 between FR47 and FR47.2.
(a) Remove upper sidewall panel 252BW (Ref. AMM TASK 25-23-43-000-001).
(b) Remove lower sidewall panel 252AW (Ref. AMM TASK 25-23-44-000-001).
(c) Remove the cove light panel 251CW, and 252CW (Ref. AMM TASK 25-23-48-000-001).
B. Make sure that the aircraft electrical circuits are de-energized
(Ref. AMM TASK 24-41-00-862-002).
4. Procedure(Ref. AMM TASK 24-41-00-862-002).
Subtask 24-92-00-210-121-A ** ON A/C NOT FOR ALL
A. General Visual Inspection of the G Route Wiring Installed Around FR47.1
(1) Do a visual inspection of the wiring to make sure that there is no signs of ageing, alteration, overheating, scaling and deformation ESPM 2052110:
(a) On the AC/DC feeder wiring: route 6G.
5. Close-up(1) Do a visual inspection of the wiring to make sure that there is no signs of ageing, alteration, overheating, scaling and deformation ESPM 2052110:
(a) On the AC/DC feeder wiring: route 6G.
NOTE: You can use a FLASHLIGHT or a MIRROR - INSPECTION, FLEXIBLE, if necessary.
(2) Make sure that there is no dust or lint contamination. Subtask 24-92-00-410-176-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the linings in zone 250 between FR47 and FR47.2.
(a) Install upper sidewall panel 252BW (Ref. AMM TASK 25-23-43-400-001).
(b) Install lower sidewall panel 252AW (Ref. AMM TASK 25-23-44-400-001).
(c) Install the cove light panel 251CW, and 252CW (Ref. AMM TASK 25-23-48-400-001).
(3) Install the furnishings in zone 250 between FR47 and FR47.2.
(a) Install the lavatories, if removed (Ref. AMM TASK 25-42-41-400-001).
(4) Close passenger/crew door 832 (842) (Ref. AMM TASK 52-10-00-410-001).
(5) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the linings in zone 250 between FR47 and FR47.2.
(a) Install upper sidewall panel 252BW (Ref. AMM TASK 25-23-43-400-001).
(b) Install lower sidewall panel 252AW (Ref. AMM TASK 25-23-44-400-001).
(c) Install the cove light panel 251CW, and 252CW (Ref. AMM TASK 25-23-48-400-001).
(3) Install the furnishings in zone 250 between FR47 and FR47.2.
(a) Install the lavatories, if removed (Ref. AMM TASK 25-42-41-400-001).
(4) Close passenger/crew door 832 (842) (Ref. AMM TASK 52-10-00-410-001).
(5) Remove the access platform(s).
Center Passenger Compartment - Inspection -Route 6G