W DOC AIRBUS | AMM A320F

General Visual Inspection of EWIS Installed in the Forward Avionic Compartment (EWIS)


TASK 24-92-00-210-027-A
General Visual Inspection of EWIS Installed in the Forward Avionic Compartment (EWIS)


ZONE: 121
ZONE: 122
1. Reason for the Job
Refer to the MPD TASK: 200121-02
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
FLASHLIGHT
No specific
AR
MIRROR - INSPECTION, FLEXIBLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
121
AVIONICS COMPARTMENT
122
AVIONICS COMPARTMENT
121AF, 121AL, 121BF, 121CF, 122BF, 811
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
TASK 53-12-13-000-001-A
Removal of the avionics compartment floor panels
TASK 53-12-13-400-001-A
Installation of the avionics compartment floor panels
ESPM 2052110
3. Job Set-up
Subtask 24-92-00-010-089-A
A. Get Access
   (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
   (2) Open the access doors:
   (3) Remove the forward avionic-compartment floor-panels 121AF 121BF 121CF 122BF (Ref. AMM TASK 53-12-13-000-001).
Subtask 24-92-00-862-077-A
B. Make sure that the aircraft electrical circuits are de-energized
(Ref. AMM TASK 24-41-00-862-002).
4. Procedure
Subtask 24-92-00-210-077-A
A. General Visual Inspection of All Wiring Installed in the Forward Avionic Compartment
   (1) Do a visual inspection of the wiring to make sure that there is no signs of ageing, alteration, overheating, scaling and deformation ESPM 2052110:
     (a) On the AC/DC feeder routes: 4G, 5G and 6G.
     (b) On the AC/DC power-distribution routes: 1P, 2P and 6P.
     (c) On the flight control wiring.
     (d) On the engine-control routes: 1S and 2S.
     (e) On the other routes: 1M and 2M.
     (f) On the audio route: 1R.
     (g) On the coaxial cable routes: 4T, 3U and 4U.
     (h) On the generator excitation routes: 1E, 2E and 3E.
NOTE: Use a FLASHLIGHT or a MIRROR - INSPECTION, FLEXIBLE if necessary.
   (2) Make sure that there is no dust, lint or hydraulic contamination.
5. Close-up
Subtask 24-92-00-410-087-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the forward avionics-compartment floor-panels 121AF 121BF 121CF 122BF (Ref. AMM TASK 53-12-13-400-001).
   (3) Close the access doors:
   (4) Remove the access platform(s).
[Rev.8 from Aug 2017] 2026.03.31 23:26:55 UTC