Apply Temporary Protection to End-Fittings of Electrical Conduits in Wing Outboard Trailing Edge
TASK 24-92-00-210-006-A
Apply Temporary Protection to End-Fittings of Electrical Conduits in Wing Outboard Trailing Edge
Refer to the MPD TASK: 240000-07
APPLY TEMPORARY PROTECTION TO END FITTINGS OF ELECTRICAL CONDUITS IN WING OUTBOARD TRAILING EDGE
Apply temporary protection to end fittings of electrical conduits in wing outboard trailing-edge.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 24-92-00-860-061-A
Subtask 24-92-00-210-055-A
Subtask 24-92-00-410-056-A
[Rev.10 from 2021]
2026.03.31 23:25:44 UTC
Apply Temporary Protection to End-Fittings of Electrical Conduits in Wing Outboard Trailing Edge
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT YOU OBEY ALL THE WARNINGS AND THE CAUTIONS INCLUDED IN THE REFERENCED PROCEDURES.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobRefer to the MPD TASK: 240000-07
APPLY TEMPORARY PROTECTION TO END FITTINGS OF ELECTRICAL CONDUITS IN WING OUTBOARD TRAILING EDGE
Apply temporary protection to end fittings of electrical conduits in wing outboard trailing-edge.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | BRUSH - BRISTLED |
| No specific | AR | SPRAY - BOTTLE, PUMP TYPE (NON AEROSOL) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.12ACB1) | Corrosion Preventive Compound-Heavy Duty Hard Film - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 575 | AFT OUTBD SE OF WING AND TE FIXED STRUCT |
| 675 | AFT OUTBD SE OF WING AND TE FIXED STRUCT |
| 575BB, 575CB, 575DB, 575EB, 575FB, 575GB, 575HB, 575KB, 575LB, 575MB, 675BB, 675CB, 675DB, 675EB, 675FB, 675GB, 675HB, 675KB, 675LB, 675MB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-34-24-869-002-A | Aircraft Grounding (Earthing) for the Maintenance Operations |
| TASK 12-34-24-869-002-A-01 | Aircraft Grounding (Earthing) during Transit, Turnaround or Overnight Stop |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 27-50-00-866-008-A | Extension of the Flaps on the Ground |
| TASK 27-50-00-866-008-A-01 | Extension of the Flaps/Slats on the Ground |
| TASK 27-50-00-866-009-A | Retraction of the Flaps on the Ground |
| TASK 27-50-00-866-009-A-01 | Retraction of the Flaps/Slats on the Ground |
| TASK 27-60-00-866-002-A | Extension-Retraction of the Spoilers for Maintenance |
| TASK 57-51-37-000-004-A | Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB) |
| TASK 57-51-37-000-005-A | Removal of the Access Panels 575KB(675KB), 575LB(675LB), 575MB(675MB) |
| TASK 57-51-37-400-004-A | Installation of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB) |
| TASK 57-51-37-400-005-A | Installation of the Access Panels 575KB(675KB), 575LB(675LB), 575MB(675MB) |
| ESPM 203330 | |
Subtask 24-92-00-860-061-A
A. Aircraft Maintenance Configuration
(1) Extend the flaps (Ref. AMM TASK 27-50-00-866-008).
(2) Extend the spoilers (Ref. AMM TASK 27-60-00-866-002).
Subtask 24-92-00-862-055-A Subtask 24-92-00-869-061-A Subtask 24-92-00-010-055-A (1) Extend the flaps (Ref. AMM TASK 27-50-00-866-008).
(2) Extend the spoilers (Ref. AMM TASK 27-60-00-866-002).
D. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the wing outboard trealing-edge.
(2) For the left wing.
(a) Remove and retain the access panel:
(a) Remove and retain the access panel:
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the wing outboard trealing-edge.
(2) For the left wing.
(a) Remove and retain the access panel:
- 575BB 575CB 575DB 575EB 575FB 575GB 575HB (Ref. AMM TASK 57-51-37-000-004)
- 575KB 575LB 575MB (Ref. AMM TASK 57-51-37-000-005).
(a) Remove and retain the access panel:
Subtask 24-92-00-210-055-A
A. Temporary Protection of the Electrical Conduits End-Fittings in the Wing Outboard Trailing-Edge
(a) Use Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) to remove any contamination from the fitting.
(b) Remove any flakes or blisters, make sure that the you do not damage the base metal while you do this task.
5. Close-upWARNING:
BE CAREFUL NOT TO CUT YOUR FINGERS. FLAKES OF NICKEL ARE SHARP.
(1) At each fitting, use the procedure that follows to protect against corrosion: (a) Use Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) to remove any contamination from the fitting.
(b) Remove any flakes or blisters, make sure that the you do not damage the base metal while you do this task.
NOTE: We recommend that you use a dental tool or a seal tool (non metallic) to remove the flakes and the blisters.
(c) Use a BRUSH - BRISTLED or an SPRAY - BOTTLE, PUMP TYPE (NON AEROSOL) to apply a continuous thin and smooth coat of Corrosion Preventive Compound-Heavy Duty Hard Film - (Material No.12ACB1) , to cover all the fitting ESPM 203330. Subtask 24-92-00-410-056-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) For the left wing.
(a) Install the access panel:
(a) Install the access panel:
Subtask 24-92-00-860-062-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) For the left wing.
(a) Install the access panel:
- 575BB 575CB 575DB 575EB 575FB 575GB 575HB (Ref. AMM TASK 57-51-37-400-004)
- 575KB 575LB 575MB (Ref. AMM TASK 57-51-37-400-005)
(a) Install the access panel:
B. Put the aircraft back to its initial configuration.
(1) Disconnect the aircraft from the ground (Ref. AMM TASK 12-34-24-869-002).
(2) Retract the spoilers (Ref. AMM TASK 27-60-00-866-002).
(3) Retract the flaps (Ref. AMM TASK 27-50-00-866-009).
(4) Remove the access platform(s).
(1) Disconnect the aircraft from the ground (Ref. AMM TASK 12-34-24-869-002).
(2) Retract the spoilers (Ref. AMM TASK 27-60-00-866-002).
(3) Retract the flaps (Ref. AMM TASK 27-50-00-866-009).
(4) Remove the access platform(s).
Location of Conduit Fittings