Operational Test of the "DC EMER CONFIG" Caution
TASK 24-34-00-710-001-A
Operational Test of the "DC EMER CONFIG" Caution
Refer to the MPD TASK: 243400-01
OPERATIONAL CHECK OF "DC EMERG. CONFIG" CAUTION
Make sure that the DC EMER CONFIG caution appears in case of loss of the DC network.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-34-00-860-050-A
Subtask 24-34-00-710-050-A
Subtask 24-34-00-410-050-A
[Rev.10 from 2021]
2026.03.31 23:23:27 UTC
Operational Test of the "DC EMER CONFIG" Caution
ZONE: 210
1. Reason for the JobRefer to the MPD TASK: 243400-01
OPERATIONAL CHECK OF "DC EMERG. CONFIG" CAUTION
Make sure that the DC EMER CONFIG caution appears in case of loss of the DC network.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 812 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
Subtask 24-34-00-860-050-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
Subtask 24-34-00-010-050-A (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
B. Get access to the avionics compartment.
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE at the avionics compartment door 812.
(2) Open the access door 812.
(3) Open the access panel on the AC/DC emergency power center 106VU.
Subtask 24-34-00-865-050-A (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE at the avionics compartment door 812.
(2) Open the access door 812.
(3) Open the access panel on the AC/DC emergency power center 106VU.
C. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | SDAC/1 AND 2/28VDC/ESS BUS | 12WV | F05 |
| 106VU | DC BUS/1 AND 2/MONG | 68WV | C03 |
Subtask 24-34-00-710-050-A
A. Operational Test of the DC EMER CONFIG Caution
5. Close-up| ACTION | RESULT |
|---|---|
1.On the panel 106VU:
| |
2.On the panel 49VU:
| On the upper ECAM DU:
|
| | On the lower ECAM DU:
|
3.On the panel 49VU:
| On the upper ECAM DU:
|
4.On the panel 106VU:
| On the upper ECAM DU:
|
Subtask 24-34-00-410-050-A
A. Close Access
(1) Close the access panel on the AC/DC emergency power center 106VU.
(2) Close the access door 812.
(3) Remove the access platform(s).
Subtask 24-34-00-860-051-A (1) Close the access panel on the AC/DC emergency power center 106VU.
(2) Close the access door 812.
(3) Remove the access platform(s).
B. Put the aircraft back to its initial configuration.
(1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).