Reactivation of the Transformer Rectifier TR2
TASK 24-30-00-440-002-A
Reactivation of the Transformer Rectifier TR2
1. Reason for the Job
MMEL 24-32-01B
DC MAIN GENERATION (TR 1, TR 2)
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 24-30-00-860-056-A
Subtask 24-30-00-440-050-A 5. Close-up
Subtask 24-30-00-860-057-A
[Rev.10 from 2021]
2026.04.01 05:49:10 UTC
Reactivation of the Transformer Rectifier TR2
1. Reason for the Job
MMEL 24-32-01B
DC MAIN GENERATION (TR 1, TR 2)
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TSM 24-30-00-810-802 | Failure of the TR2 or TR2 Contactor or Related Wiring |
Subtask 24-30-00-860-056-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
4. Procedure(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
Subtask 24-30-00-440-050-A 5. Close-up
Subtask 24-30-00-860-057-A
A. Put the aircraft back to its initial configuration.
(1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).