W DOC AIRBUS | AMM A320F

Installation of the Attendant Indication Panel


TASK 23-73-22-400-001-A
Installation of the Attendant Indication Panel


ZONE: 200
FIN: 320RH1
FIN: 320RH10 ** ON A/C NOT FOR ALL
FIN: 320RH11 ** ON A/C NOT FOR ALL
FIN: 320RH9
FIN: 321RH ** ON A/C NOT FOR ALL
FIN: 322RH1 ** ON A/C NOT FOR ALL
FIN: 322RH11 ** ON A/C NOT FOR ALL
FIN: 322RH2 ** ON A/C NOT FOR ALL
FIN: 322RH3 ** ON A/C NOT FOR ALL
FIN: 322RH4 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
98A25208001000
1
PULLEY ASSY-SEALING
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 23-73-00-740-005-A
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
TASK 23-73-00-740-005-B
Interface and Power-Up Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
TASK 23-73-00-861-001-A
Energize the Cabin Intercommunication Data System (CIDS)
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 26-10-00-740-801-A
BITE Test of the Smoke Detection Function - System Test
TASK 23-73-00-00-01
CABIN INTERCOMMUNICATION DATA SYSTEM (CIDS) - DESCRIPTION AND OPERATION
F Attendant Indication Panel ** ON A/C NOT FOR ALL
F Attendant Indication Panel ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 23-73-22-861-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 23-73-22-861-051-B ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) For the location of this component, refer to paragraph Component Location
(Ref. AMM D/O 23-73-00-00).
Subtask 23-73-22-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUCOM/CIDS/DEU B/ESS153RHG03
** ON A/C NOT FOR ALL
49VUCOM/CIDS/DEU B ESS/R420RHG05
49VUCOM/CIDS/DEU B ESS/L419RHG04
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU B/NORM162RHM08
** ON A/C NOT FOR ALL
121VUCOM / CIDS / DEU B / NORM FWD193RHM09
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU B NORM/R620RHM08
121VUCOM NAV/CIDS/DEU B NORM/L619RHM07
121VUCOM/CIDS/DEU B BAT/R720RHQ11
121VUCOM/CIDS/DEU B BAT/L719RHQ10
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU B/NORM162RHM09
** ON A/C NOT FOR ALL
121VUCOM/CIDS/DEU B/BAT143RHN12
** ON A/C NOT FOR ALL
2001VUCIDS-DEU B-NORM-AFT194RHC08
4. Procedure
Subtask 23-73-22-420-051-A ** ON A/C NOT FOR ALL
A. Installation of the Attendant Indication Panel (AIP)
F Attendant Indication Panel ** ON A/C NOT FOR ALL
F Attendant Indication Panel ** ON A/C NOT FOR ALL
   (1) Install the AIP in the Passenger Service Information Unit (PSIU)
     (a) Do an inspection of the component interfaces and the adjacent area.
     (b) Clean the component interfaces and the adjacent area.
     (c) Remove the CAP-BLANKING from each electrical connector and receptacle.
     (d) Make sure that all the electrical connections are clean and in the correct condition.
     (e) Connect the electrical connector (8) to the AIP (9).
     (f) Install the AIP (9) on the PSIU (3) with the screws (6), the washers (5) and the nuts (7).
     (g) Tighten the screws (6).
     (h) Install the cover (4) on the AIP (9) and make sure that it locks in position with a click.
     (i) Make sure that the work area is clean and clear of tools and other items.
     (j) Lift and engage the PSIU (3) with the mounting rail (2).
     (k) Install the section hose (1) with the 98A25208001000 PULLEY ASSY-SEALING on the mounting rail (2).
     (l) Make sure that the section hose is not stretched.
     (m) Move the pulley assembly quickly forward and rearward to prevent this.
   (2) Install the Attendant Indication Panel (AIP) in the cabin
     (a) Do an inspection of the component interfaces and the adjacent area.
     (b) Clean the component interfaces and the adjacent area.
     (c) Remove the CAP-BLANKING from each electrical connector and receptacle.
     (d) Make sure that all the electrical connections are clean and in the correct condition.
     (e) Connect the electrical connector (8) to AIP (9).
     (f) Attach the AIP (9) with the screws (6) and the washers (5).
     (g) Tighten the screws (6).
     (h) Install the cover (4) on the AIP (9) and make sure that it locks in position with a click.
     (i) Make sure that the work area is clean and clear of tools and other items.
Subtask 23-73-22-420-051-E ** ON A/C NOT FOR ALL
A. Installation of the Attendant Indication Panel (AIP)
   (1) Install the AIP in the Passenger Service Information Unit (PSIU)
     (a) Do an inspection of the component interfaces and the adjacent area.
     (b) Clean the component interfaces and the adjacent area.
     (c) Remove the CAP-BLANKING from each electrical connector and receptacle.
     (d) Make sure that all the electrical connections are clean and in the correct condition.
     (e) Connect the electrical connector (7) to the AIP (8).
     (f) Install the AIP (8) on the PSIU (3) with the screws (5) and the washers (6).
     (g) Tighten the screws (5).
     (h) Install the cover (4) on the AIP (8) and make sure that it locks in position with a click.
     (i) Make sure that the work area is clean and clear of tools and other items.
     (j) Lift and engage the PSIU (3) with the mounting rail (2).
     (k) Install the section hose (1) with the 98A25208001000 PULLEY ASSY-SEALING on the mounting rail (2).
     (l) Make sure that the section hose is not stretched.
     (m) Move the pulley assembly quickly forward and rearward to prevent this.
   (2) Install the Attendant Indication Panel (AIP) in the cabin
     (a) Do an inspection of the component interfaces and the adjacent area.
     (b) Clean the component interfaces and the adjacent area.
     (c) Remove the CAP-BLANKING from each electrical connector and receptacle.
     (d) Make sure that all the electrical connections are clean and in the correct condition.
     (e) Connect the electrical connector (7) to AIP (8).
     (f) Install the AIP (8) with the screws (5) and the washers (6).
     (g) Tighten the screws (5).
     (h) Install the cover (4) on the AIP (8) and make sure that it locks in position with a click.
     (i) Make sure that the work area is clean and clear of tools and other items.
Subtask 23-73-22-865-056-A
B. Remove the safety clips and tags and close these circuit breakers in this sequence:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUCIDS-DEU B-NORM-AFT194RHC08
121VUCOM / CIDS / DEU B / NORM FWD193RHM09
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU B/NORM162RHM09
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU B/NORM162RHM08
** ON A/C NOT FOR ALL
49VUCOM/CIDS/DEU B/ESS153RHG03
** ON A/C NOT FOR ALL
121VUCOM/CIDS/DEU B/BAT143RHN12
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU B NORM/L619RHM07
121VUCOM NAV/CIDS/DEU B NORM/R620RHM08
49VUCOM/CIDS/DEU B ESS/L419RHG04
49VUCOM/CIDS/DEU B ESS/R420RHG05
121VUCOM/CIDS/DEU B BAT/L719RHQ10
121VUCOM/CIDS/DEU B BAT/R720RHQ11
Subtask 23-73-22-869-050-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) Make sure that the Cabin Intercommunication Data System (CIDS) is energized
(Ref. AMM TASK 23-73-00-861-001).
   (2) Do the BITE test of the Cabin Intercommunication Data System (CIDS) (Ref. AMM TASK 23-73-00-740-005).
Subtask 23-73-22-869-050-B ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) Make sure that the Cabin Intercommunication Data System (CIDS) is energized
(Ref. AMM TASK 23-73-00-861-001).
   (2) Do the Interface and Power-Up test of the Cabin Intercommunication Data System (CIDS) (Ref. AMM TASK 23-73-00-740-005).
Subtask 23-73-22-740-052-A ** ON A/C NOT FOR ALL
D. Do the BITE test of the smoke detection function - system test
(Ref. AMM TASK 26-10-00-740-801).
5. Close-up
Subtask 23-73-22-862-050-A
A. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.03.31 23:18:09 UTC