Installation of the On-Board Replaceable Module
TASK 23-73-21-400-001-A
Installation of the On-Board Replaceable Module
Self Explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 23-73-21-861-051-A ** ON A/C NOT FOR ALL Subtask 23-73-21-865-050-A ** ON A/C NOT FOR ALL
Subtask 23-73-21-420-050-A ** ON A/C NOT FOR ALL
Subtask 23-73-21-862-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 04:42:38 UTC
Installation of the On-Board Replaceable Module
FIN: 116RH ** ON A/C NOT FOR ALL
1. Reason for the JobSelf Explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 20-15-00-910-001-A | Handling Precautions for Electrostatic Discharge Sensitive Devices |
| TASK 23-73-00-740-005-B | Interface and Power-Up Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| TASK 23-73-00-869-001-A | OBRM - Download Procedure |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 26-10-00-710-801-A | Smoke Detection Function Cabin Assignment Module (SDF CAM) Layout Loading |
| TASK 26-10-00-740-801-A | BITE Test of the Smoke Detection Function - System Test |
Subtask 23-73-21-861-051-A ** ON A/C NOT FOR ALL Subtask 23-73-21-865-050-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/DIR ESS/2 | 157RH | G02 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/DIR ESS/1 | 150RH | G01 |
| 49VU | COM/CIDS/FLT ATTND PNL/ESS | 171RH | H01 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM DIR ESS/2 | 157RH | G02 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/FLT ATTND PNL/ESS | 171RH | G03 |
| 49VU | COM NAV/CIDS/DIR2 ESS | 157RH | G02 |
| 49VU | COM NAV/CIDS/DIR1 ESS | 150RH | G01 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM CIDS FWD ATTND PNL | 170RH | Q14 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DIR NORM/2 | 156RH | M06 |
| 121VU | COM NAV/CIDS/DIR NORM/1 | 151RH | M05 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM/FAP1/NORM | 170RH | Q14 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DIR NORM/2 | 156RH | M07 |
| 121VU | COM NAV/CIDS/DIR NORM/1 | 151RH | M06 |
| 121VU | COM NAV/CIDS/FWD ATTND/PNL | 170RH | Q14 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DIR2 NORM | 156RH | M06 |
| 121VU | COM NAV/CIDS/DIR1 NORM | 151RH | M05 |
| 121VU | COM/CIDS/FWD ATTND PNL/BAT | 149RH | Q13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM/CIDS/FLT ATTND PANL/BAT | 149RH | Q13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM/CIDS/DIR 2/BAT | 146RH | P14 |
| 121VU | COM/CIDS/DIR 1/BAT | 147RH | P13 |
Subtask 23-73-21-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the On-Board Replaceable Module (OBRM)
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Before you touch the OBRM, do the procedure for devices that are sensitive to electrostatic discharge (Ref. AMM TASK 20-15-00-910-001).
(4) Push the OBRM (4) carefully into the respective slot, the OBRM slot (5), until it locks in position.
(6) Close the cover (2) and the quick-release fastener (1).
Subtask 23-73-21-865-052-A ** ON A/C NOT FOR ALL CAUTION:
MAKE SURE THAT YOU USE WRIST STRAPS WHEN YOU REMOVE AND INSTALL AN ONBOARD REPLACEABLE MODULE (OBRM).
WRIST STRAPS WILL PREVENT POSSIBLE ELECTROSTATIC DISCHARGES, WHICH CAN CAUSE DAMAGE TO THE OBRM'S.
(1) Clean the component interfaces and the adjacent area.(2) Do an inspection of the component interfaces and the adjacent area.
(3) Before you touch the OBRM, do the procedure for devices that are sensitive to electrostatic discharge (Ref. AMM TASK 20-15-00-910-001).
(4) Push the OBRM (4) carefully into the respective slot, the OBRM slot (5), until it locks in position.
NOTE: The I-PRAM, CAM and OBRM slot has the same dimensions. Thus it is mandatory to push the Compact Flashcard into the correct slot.
(5) Make sure that the work area is clean and clear of tools and other items.(6) Close the cover (2) and the quick-release fastener (1).
B. Remove the safety clips and tags and close these circuit breakers in this sequence:
Subtask 23-73-21-740-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM CIDS FWD ATTND PNL | 170RH | Q14 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM/FAP1/NORM | 170RH | Q14 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/FWD ATTND/PNL | 170RH | Q14 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/FLT ATTND PNL/ESS | 171RH | H01 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/FLT ATTND PNL/ESS | 171RH | G03 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM/CIDS/FLT ATTND PANL/BAT | 149RH | Q13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM/CIDS/FWD ATTND PNL/BAT | 149RH | Q13 |
| 121VU | COM NAV/CIDS/DIR2 NORM | 156RH | M06 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DIR NORM/2 | 156RH | M07 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DIR NORM/2 | 156RH | M06 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DIR1 NORM | 151RH | M05 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DIR NORM/1 | 151RH | M06 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DIR NORM/1 | 151RH | M05 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM NAV/CIDS/DIR2 ESS | 157RH | G02 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/DIR ESS/2 | 157RH | G02 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM DIR ESS/2 | 157RH | G02 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM NAV/CIDS/DIR1 ESS | 150RH | G01 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/DIR ESS/1 | 150RH | G01 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM/CIDS/DIR 1/BAT | 147RH | P13 |
| 121VU | COM/CIDS/DIR 2/BAT | 146RH | P14 |
C. OBRM - Software Loading, Configuration Test, Interface and Power-Up Test
(1) On the Flight Attendant Panel (FAP), push the SW Load key.
(Ref. AMM TASK 23-73-00-740-005)
Subtask 23-73-21-740-050-B ** ON A/C NOT FOR ALL (1) On the Flight Attendant Panel (FAP), push the SW Load key.
- The indicator light in the SW Load key comes on.
- The SOFTWARE LOADING page shows.
- The message box WAIT UNTIL ALL CIDS COMPONENTS HAVE SENT THEIR CONFIGURATION shows.
- Wait approx. 2 minutes, then the message box goes off.
- Do the OBRM download procedure.
(Ref. AMM TASK 23-73-00-869-001)
NOTE: If no component with an amber background shows on the SOFTWARE LOADING page, no OBRM software download is required.
NOTE: You can ignore the message CHANGE CAM NOW IF NECESSARY.
(3) Do the Interface and Power-Up test of the CIDS. (Ref. AMM TASK 23-73-00-740-005)
C. OBRM - Software Loading, Configuration Test, Interface and Power-Up Test
(1) On the Flight Attendant Panel (FAP), push the SW Load key.
(Ref. AMM TASK 23-73-00-740-005)
(4) Do the BITE test of the Smoke Detection Function (SDF).
(Ref. AMM TASK 26-10-00-740-801)
Subtask 23-73-21-740-050-C ** ON A/C NOT FOR ALL (1) On the Flight Attendant Panel (FAP), push the SW Load key.
- The indicator light in the SW Load key comes on.
- The SOFTWARE LOADING page shows.
- The message box WAIT UNTIL ALL CIDS COMPONENTS HAVE SENT THEIR CONFIGURATION shows.
- Wait approx. 2 minutes, then the message box goes off.
- Do the OBRM download procedure.
(Ref. AMM TASK 23-73-00-869-001)
NOTE: If no component with an amber background shows on the SOFTWARE LOADING page, no OBRM software download is required.
NOTE: You can ignore the message CHANGE CAM NOW IF NECESSARY.
(3) Do the Interface and Power-Up test of the CIDS. (Ref. AMM TASK 23-73-00-740-005)
(4) Do the BITE test of the Smoke Detection Function (SDF).
(Ref. AMM TASK 26-10-00-740-801)
C. OBRM - Software Loading, Configuration Test, Interface and Power-Up Test
(1) On the Flight Attendant Panel (FAP), push the SW Load key.
(Ref. AMM TASK 26-10-00-710-801)
(4) Do the Interface and Power-Up test of the CIDS.
(Ref. AMM TASK 23-73-00-740-005)
(5) Do the BITE test of the Smoke Detection Function (SDF).
(Ref. AMM TASK 26-10-00-740-801)
5. Close-up(1) On the Flight Attendant Panel (FAP), push the SW Load key.
- The indicator light in the SW Load key comes on.
- The SOFTWARE LOADING page shows.
- The message box WAIT UNTIL ALL CIDS COMPONENTS HAVE SENT THEIR CONFIGURATION shows.
- Wait approx. 2 minutes, then the message box goes off.
- Do the OBRM download procedure.
(Ref. AMM TASK 23-73-00-869-001)
NOTE: If no component with an amber background shows on the SOFTWARE LOADING page, no OBRM software download is required.
NOTE: You can ignore the message CHANGE CAM NOW IF NECESSARY.
(3) Load the SMOKE LAYOUT into SDF1 and SDF2. (Ref. AMM TASK 26-10-00-710-801)
(4) Do the Interface and Power-Up test of the CIDS.
(Ref. AMM TASK 23-73-00-740-005)
(5) Do the BITE test of the Smoke Detection Function (SDF).
(Ref. AMM TASK 26-10-00-740-801)
Subtask 23-73-21-862-050-A ** ON A/C NOT FOR ALL
On-Board Replaceable Module