Functional Test of the FWD Cargo-Compartment Ventilation-System
TASK 21-28-00-720-003-A
Functional Test of the FWD Cargo-Compartment Ventilation-System
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 21-28-00-861-066-A ** ON A/C NOT FOR ALL Subtask 21-28-00-865-068-A ** ON A/C NOT FOR ALL
Subtask 21-28-00-720-054-A ** ON A/C NOT FOR ALL
Subtask 21-28-00-860-060-A ** ON A/C NOT FOR ALL Subtask 21-28-00-410-062-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:03:59 UTC
Functional Test of the FWD Cargo-Compartment Ventilation-System
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 131QW, 132KW, 825 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 21-28-00-710-004-A | Operational Test of the FWD Cargo-Compartment Outlet Isolation-Valve in the Ditching Configuration |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 25-54-12-000-003-A | Removal of the Sidewall Panels in the Forward Cargo Compartment |
| TASK 25-54-12-400-003-A | Installation of the Sidewall Panels in the Forward Cargo Compartment |
| TASK 26-16-00-710-003-A | Operational Check of Cargo Compartment Smoke Detection by CFDS to Confirm Isolation Valves Latching Circuit Integrity. |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 21-28-00-861-066-A ** ON A/C NOT FOR ALL Subtask 21-28-00-865-068-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 21-28-00-010-061-B ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/FWD CARGO/VENT/CTL & MONG | 2HN | C08 |
| 49VU | AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC | 52HH | D08 |
| 122VU | FWD CARGO VENT AND HTG/FAN | 1HN | T22 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/115VAC | 53HH | W22 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN A/28VDC | 55HH | W21 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/115VAC | 49HH | X22 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN A/28VDC | 51HH | X21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/28VDC | 56HH | Y21 |
| 122VU | AIR COND/TEMP CTL SYS 2/CHAN B/115VAC | 54HH | Y20 |
| 122VU | AIR COND/TEMP CTL SYS 1/CHAN B/115VAC | 50HH | Y18 |
C. Get Access
(1) Open the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) in position at the FWD cargo-compartment door 825.
(3) Remove the access panels 132KW and 131QW (Ref. AMM TASK 25-54-12-000-003).
Subtask 21-28-00-860-059-A ** ON A/C NOT FOR ALL (1) Open the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) in position at the FWD cargo-compartment door 825.
(3) Remove the access panels 132KW and 131QW (Ref. AMM TASK 25-54-12-000-003).
D. Aircraft Maintenance Configuration
(1) On the overhead panel 22VU make sure that the FWD ISOL VALVE pushbutton switch is in the off position (the OFF legend is on).
(2) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
(3) Make sure that the ENGINE/WARNING page shows on the ECAM upper display unit.
4. Procedure(1) On the overhead panel 22VU make sure that the FWD ISOL VALVE pushbutton switch is in the off position (the OFF legend is on).
(2) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
(3) Make sure that the ENGINE/WARNING page shows on the ECAM upper display unit.
Subtask 21-28-00-720-054-A ** ON A/C NOT FOR ALL
A. Functional Test of the FWD Cargo-Compartment Ventilation-System
Subtask 21-28-00-710-060-A ** ON A/C NOT FOR ALL NOTE: During the test you must visually monitor the inlet and the outlet isolation valves for the correct movement sequence.
| ACTION | RESULT |
|---|---|
1.On the panel 22VU:
| On the panel 22VU:
|
| | In the FWD cargo compartment:
|
2.On the outlet isolation valve 4HN:
| On the ECAM upper display unit:
|
| | On the panel 22VU:
|
| | In the FWD cargo compartment:
|
3.On the panel 22VU:
| On the panel 22VU:
|
| | In the FWD cargo compartment:
|
4.On the outlet isolation valve 4HN:
| On the panel 22VU:
|
| | On the ECAM upper display unit:
|
| | In the FWD cargo compartment:
|
5.On the panel 22VU:
| On the panel 22VU:
|
| | In the FWD cargo compartment:
|
6.On the panel 22VU:
| On the panel 22VU:
|
| | In the FWD cargo compartment:
|
B. Operational Tests
(1) Do the operational test of the FWD cargo-compartment smoke-detection with the CFDS to confirm isolation valve latching circuit integrity. (Ref. AMM TASK 26-16-00-710-003).
(2) Do the operational test of the FWD cargo-compartment outlet isolation-valve in the ditching configuration (Ref. AMM TASK 21-28-00-710-004).
5. Close-up(1) Do the operational test of the FWD cargo-compartment smoke-detection with the CFDS to confirm isolation valve latching circuit integrity. (Ref. AMM TASK 26-16-00-710-003).
(2) Do the operational test of the FWD cargo-compartment outlet isolation-valve in the ditching configuration (Ref. AMM TASK 21-28-00-710-004).
Subtask 21-28-00-860-060-A ** ON A/C NOT FOR ALL Subtask 21-28-00-410-062-B ** ON A/C NOT FOR ALL
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panels 132KW and 131QW (Ref. AMM TASK 25-54-12-400-003).
(3) Remove the access platform(s).
(4) Close the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
Subtask 21-28-00-862-062-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panels 132KW and 131QW (Ref. AMM TASK 25-54-12-400-003).
(3) Remove the access platform(s).
(4) Close the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).