W DOC AIRBUS | AMM A320F

Operational Test of the AFT Cargo-Compartment Ventilation-System


TASK 21-28-00-710-006-A
Operational Test of the AFT Cargo-Compartment Ventilation-System


1. Reason for the Job
There are alternative procedures in this task:
  • For aircraft WITH ventilation isolation valve position indications on the ECAM COND page.
  • For aircraft WITHOUT ventilation isolation valve position indications on the ECAM COND page.
  • Do a check of the aircraft configuration with regard to these ECAM indications before you do the test.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
162DW
151EW
151VW
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 25-55-11-000-003-A
Removal of the Sidewall Panels in the Aft Cargo Compartment - FR47/FR59
TASK 25-55-11-400-003-A
Installation of the Sidewall Panels in the Aft Cargo Compartment - FR47/FR59
TASK 25-55-12-000-001-A
Removal of the Aft Cargo-Compartment Partition at FR65
TASK 25-55-12-400-001-A
Installation of the Aft Cargo-Compartment Partition at FR65
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 21-28-00-861-070-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 21-28-00-865-072-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/AFT CARGO/VENT/CTL & MONG31HNC07
** ON A/C NOT FOR ALL
49VUAIR COND/AFT CARGO/VENT & HTG/CTL & MONG31HNC07
** ON A/C NOT FOR ALL
122VUAIR COND/ZONE TEMP CTL/28VDC/SYS24HKV20
122VUAIR COND/ZONE TEMP CTL/28VDC/SYS13HKV19
122VUAIR COND/ZONE TEMP CTL/115VAC/SYS22HKV18
122VUAIR COND/ZONE TEMP CTL/115VAC/SYS11HKV17
** ON A/C NOT FOR ALL
122VUAIR COND/AFT CARGO VENT/FAN30HNS22
Subtask 21-28-00-865-090-A ** ON A/C NOT FOR ALL
C. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/AFT CARGO/VENT/CTL & MONG31HNC07
** ON A/C NOT FOR ALL
49VUAIR COND/AFT CARGO/VENT & HTG/CTL & MONG31HNC07
Subtask 21-28-00-010-065-A ** ON A/C NOT FOR ALL
D. Get Access
NOTE: This procedure is only applicable for aircraft WITHOUT ventilation isolation valve positions indicated on the ECAM COND page.
   (1) Open the AFT cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-001).
   (2) Put the ACCESS PLATFORM 2M (6 FT) at the AFT cargo-compartment door 826.
   (3) Remove the access panel 162DW (Ref. AMM TASK 25-55-12-000-001).
   (4) Remove the access panel 151EW (Ref. AMM TASK 25-55-11-000-003).
Subtask 21-28-00-010-065-C ** ON A/C NOT FOR ALL
D. Get Access
NOTE: This procedure is only applicable for aircraft WITHOUT ventilation isolation valve positions indicated on the ECAM COND page.
   (1) Open the AFT cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-001).
   (2) Put the ACCESS PLATFORM 2M (6 FT) at the AFT cargo-compartment door 826.
   (3) Remove the access panel 162DW (Ref. AMM TASK 25-55-12-000-001).
   (4) Remove the access panel 151VW (Ref. AMM TASK 25-55-11-000-003).
Subtask 21-28-00-860-056-A ** ON A/C NOT FOR ALL
E. Aircraft Maintenance Configuration
NOTE: This procedure is only applicable for aircraft WITHOUT ventilation isolation valve positions indicated on the ECAM COND page.
   (1) On the overhead panel 22VU make sure that the white OFF light in the AFT ISOL VALVE pushbutton switch is on.
Subtask 21-28-00-860-063-A ** ON A/C NOT FOR ALL
F. Aircraft Maintenance Configuration
NOTE: This procedure is only applicable for aircraft WITH ventilation isolation valve positions indicated on the ECAM COND page.
   (1) On the overhead panel 22VU make sure that the white OFF light in the AFT ISOL VALVE pushbutton switch is on.
   (2) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
   (3) Make sure that the COND page shows on the ECAM lower display unit.
4. Procedure
Subtask 21-28-00-710-059-A ** ON A/C NOT FOR ALL
A. Do the Operational Test of the Ventilation System
NOTE: This procedure is only applicable for aircraft WITHOUT ventilation isolation valve positions indicated on the ECAM COND page.
During the test you must visually monitor the isolation valves for correct movement sequence.
ACTION
RESULT
1.On the panel 22VU:
  • push the AFT ISOL VALVE pushbutton switch.
On the panel 22VU:
  • the white OFF light in the AFT ISOL VALVE pushbutton switch goes off.

In the AFT cargo compartment:
  • the inlet and outlet isolation valves open.
  • the extraction fan operates after approx. 15 s.
2.On the panel 22VU:
  • push the AFT ISOL VALVE pushbutton switch.
On the panel 22VU:
  • the white OFF light in the AFT ISOL VALVE pushbutton switch comes on.

In the AFT cargo compartment:
  • the extraction fan stops.
  • the inlet and outlet isolation valves close.
Subtask 21-28-00-710-065-A ** ON A/C NOT FOR ALL
B. Do the Operational Test of the Ventilation System
NOTE: This procedure is only applicable for aircraft WITH ventilation isolation valve positions indicated on the ECAM COND page.
ACTION
RESULT
1.On the panel 22VU:
  • push the AFT ISOL VALVE pushbutton switch.
On the panel 22VU:
  • the white OFF light in the AFT ISOL VALVE pushbutton switch goes off.

On the ECAM lower display units:
  • the inlet and outlet isolation valve symbols open and change to green.
2.On the panel 22VU:
  • push the AFT ISOL VALVE pushbutton switch.
On the panel 22VU:
  • the white OFF light in the AFT ISOL VALVE pushbutton switch comes on.

On the ECAM lower display unit:
  • the inlet and outlet isolation valve symbols close and change to amber.
5. Close-up
Subtask 21-28-00-860-057-A ** ON A/C NOT FOR ALL
A. Do the EIS stop procedure
NOTE: This procedure is only applicable for aircraft WITH ventilation isolation valve positions indicated on the ECAM COND page.
(Ref. AMM TASK 31-60-00-860-002).
Subtask 21-28-00-410-066-A ** ON A/C NOT FOR ALL
B. Close Access
NOTE: This procedure is only applicable for aircraft WITHOUT ventilation isolation valve positions indicated on the ECAM COND page.
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the access panel 162DW (Ref. AMM TASK 25-55-12-400-001).
   (3) Install the access panel 151EW (Ref. AMM TASK 25-55-11-400-003).
   (4) Remove the access platform(s).
   (5) Close the AFT cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-002).
Subtask 21-28-00-410-066-C ** ON A/C NOT FOR ALL
B. Close Access
NOTE: This procedure is only applicable for aircraft WITHOUT ventilation isolation valve positions indicated on the ECAM COND page.
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the access panel 162DW (Ref. AMM TASK 25-55-12-400-001).
   (3) Install the access panel 151VW (Ref. AMM TASK 25-55-11-400-003).
   (4) Remove the access platform(s).
   (5) Close the AFT cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-002).
Subtask 21-28-00-862-066-A ** ON A/C NOT FOR ALL
C. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 04:25:49 UTC