Visual Inspection of the Pneumatic Air Starter [CFML]
TASK 80-11-05-210-802-A
Visual Inspection of the Pneumatic Air Starter
This check must be done if a Foreign Object Damage (FOD) is found:
- Damage can cause a slow start or no start.
- This check is also necessary, if there is an indication of IP bleed check valve damage (cracks, missing segments or wear out of limits).
This check is also necessary, if generation of debris due to significant High Pressure Compressor damage causing FOD ingestion in the bleed system.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 80-11-05-941-055-A
Subtask 80-11-05-210-051-A
Subtask 80-11-05-410-053-A
[Rev.10 from 2021]
2026.04.01 13:04:16 UTC
Visual Inspection of the Pneumatic Air Starter
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
1. Reason for the JobThis check must be done if a Foreign Object Damage (FOD) is found:
- Damage can cause a slow start or no start.
- This check is also necessary, if there is an indication of IP bleed check valve damage (cracks, missing segments or wear out of limits).
This check is also necessary, if generation of debris due to significant High Pressure Compressor damage causing FOD ingestion in the bleed system.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | LIGHT SOURCE - INSPECTION |
| No specific | 1 | MIRROR - INSPECTION |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1) | |
| 437AL, 438AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 36-11-41-200-803-A | Removal of the Intermediate-Pressure Bleed Check-Valve for Detailed Inspection |
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-803-A | Closing of the Fan Cowl Doors |
| TASK 80-11-05-000-801-A | Removal of the Pneumatic Air Starter |
| TASK 80-11-05-400-801-A | Installation of the Pneumatic Air Starter |
| TASK 80-11-15-000-801-A | Removal of the Starter Air Valve (SAV) |
| TASK 80-11-15-400-801-A | Installation of the Starter Air Valve (SAV) |
Subtask 80-11-05-941-055-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 80-11-05-010-055-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
- The ENG/MODE selector switch, and
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
Subtask 80-11-05-210-051-A
A. Examine the Pneumatic Air Starter
(1) Remove the Starter Air Valve (SAV) (Ref. AMM TASK 80-11-15-000-801).
(2) Introduce an MIRROR - INSPECTION and an LIGHT SOURCE - INSPECTION in the starter exhaust, examine the diffuser vane for signs of Foreign Object Damage (FOD):
(a) Replace the pneumatic air starter (Ref. AMM TASK 80-11-05-000-801) and (Ref. AMM TASK 80-11-05-400-801).
(b) Examine the Intermediate Pressure (IP) bleed check valve (Ref. AMM TASK 36-11-41-200-803) if the starter inspection is not applied per these tasks.
(c) Examine the pylon interface duct.
(d) If there are no signs of FOD, install the SAV (Ref. AMM TASK 80-11-15-400-801).
5. Close-up(1) Remove the Starter Air Valve (SAV) (Ref. AMM TASK 80-11-15-000-801).
(2) Introduce an MIRROR - INSPECTION and an LIGHT SOURCE - INSPECTION in the starter exhaust, examine the diffuser vane for signs of Foreign Object Damage (FOD):
- Scratches, dents, missing segments
- Signs of impact.
(a) Replace the pneumatic air starter (Ref. AMM TASK 80-11-05-000-801) and (Ref. AMM TASK 80-11-05-400-801).
(b) Examine the Intermediate Pressure (IP) bleed check valve (Ref. AMM TASK 36-11-41-200-803) if the starter inspection is not applied per these tasks.
(c) Examine the pylon interface duct.
(d) If there are no signs of FOD, install the SAV (Ref. AMM TASK 80-11-15-400-801).
Subtask 80-11-05-410-053-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(3) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(3) Remove the WARNING NOTICE(S).
Pneumatic Air Starter